EN 13637:2015
Current
The latest, up-to-date edition.
Building hardware - Electrically controlled exit systems for use on escape routes - Requirements and test methods
10-06-2015
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and
sampling methods
6 Assessment and verification
of constancy of performance - AVCP
7 Classification and designation
8 Marking, labelling and packaging
Annex A (informative) - Information supplied
with the product
Annex B (normative) - Test sequences with
different samples
Annex C (informative) - Guidance for choosing
relevant product standards for particular
exit door applications
Annex D (informative) - Access levels, Installation
and maintenance
Annex E (informative) - Functional diagrams
Annex F (informative) - Examples of configurations
and description of exit systems
Annex ZA (informative) - Clauses of this
European Standard addressing the
provisions of the EU Construction
Products Regulation
This European standard specifies requirements for the manufacture; performance and testing of electrically controlled exit systems, designed for use on escape routes. These systems consist of at least the following elements:- Initiating element for requesting the release of electrical locking element in order to exit;- Electrical locking element for securing an exit door;- Electrical controlling element for supplying, connecting and controlling electrical locking element and initiating element. In addition, these electrically controlled exit systems can include time delay and/or denied exit mode. This European Standard covers electrically controlled exit systems placed on the market as a complete unit (e.g. mortise lock, lever handle, keeper, initiating element, electrical locking element, electrical controlling element, etc.). The components are tested as a single product. This European Standard covers electrically controlled exit systems which are either manufactured and placed on the market in their entirety by one manufacturer or assembled from sub-assemblies produced by more than one manufacturer and subsequently placed on the market as a kit in a single transaction. The suitability of an electrically controlled exit system for use on fire/smoke resisting door assemblies is determined by fire performance tests conducted in addition to the performance tests required by this European Standard.
Committee |
CEN/TC 33
|
DevelopmentNote |
Supersedes PREN 13637. (06/2015)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN EN 13637:2015-12 | Identical |
PN EN 13637 : 2015 | Identical |
UNI EN 13637 : 2015 | Identical |
SN EN 13637 : 2015 | Identical |
NF EN 13637 : 2015 | Identical |
NBN EN 13637 : 2015 | Identical |
I.S. EN 13637:2015 | Identical |
NEN EN 13637 : 2015 | Identical |
UNE-EN 13637:2016 | Identical |
NS EN 13637 : 2015 | Identical |
BS EN 13637:2015 | Identical |
BS EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows. Product standard, performance characteristics. Fire resisting and/or smoke control characteristics |
I.S. EN 16034:2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
PREN 1125 : DRAFT 2016 | BUILD HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
PREN 50518 : DRAFT 2016 | MONITORING AND ALARM RECEIVING CENTRE |
PREN 179 : DRAFT 2016 | BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
UNE-EN 16034:2015 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
DIN EN 16034:2014-12 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS |
16/30343246 DC : 0 | BS EN 1125 - BUILDING HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
16/30299842 DC : 0 | BS EN 50518 - MONITORING AND ALARM RECEIVING CENTRE |
16/30343249 DC : 0 | BS EN 179 - BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
NS-EN 16867:2020+A2:2024 | Building hardware - Mechatronic door furniture - Requirements and test methods |
ISO 7010:2011 | Graphical symbols Safety colours and safety signs Registered safety signs |
EN 60947-5-5 : 1997 AMD 2 2016 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-5: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTRICAL EMERGENCY STOP DEVICE WITH MECHANICAL LATCHING FUNCTION (IEC 60947-5-5:1997/A2:2016) |
EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
EN 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
IEC 60050-845:1987 | International Electrotechnical Vocabulary (IEV) - Part 845: Lighting |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 1634-2:2008 | Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN ISO 7010 : 2012 AMD 7 2017 | GRAPHICAL SYMBOLS - SAFETY COLOURS AND SAFETY SIGNS - REGISTERED SAFETY SIGNS (ISO 7010:2011/AMD 7:2016) |
IEC 60947-5-5:1997+AMD1:2005+AMD2:2016 CSV | Low-voltage switchgear and controlgear - Part 5-5: Control circuitdevices and switching elements - Electrical emergency stop device with mechanical latching function |
EN 179:2008 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.