EN 1822-2:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
High efficiency air filters (EPA, HEPA and ULPA) - Part 2: Aerosol production, measuring equipment, particle counting statistics
26-02-2020
18-11-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Aerosol production
5 Measuring devices
6 Maintenance and inspection intervals
7 Particle counting statistics
Bibliography
This European Standard applies to efficient particulate air filters (EPA), high efficiency particulate air filters (HEPA) and ultra low penetration air filters (ULPA) used in the field of ventilation and air conditioning and for technical processes, e.g. for applications in clean room technology or pharmaceutical industry.It establishes a procedure for the determination of the efficiency on the basis of a particle counting method using a liquid (or alternatively a solid) test aerosol, and allows a standardized classification of these filters in terms of their efficiency, both local and integral efficiency.This European Standard describes the measuring instruments and aerosol generators used in the course of this testing. With regard to particle counting it specifies the statistical basis for the evaluation of counts with only small numbers of counted events.
Committee |
CEN/TC 195
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NBN EN 1822-2 : 2010 | Identical |
SN EN 1822-2 : 2010 | Identical |
UNE-EN 1822-2:2010 | Identical |
NF EN 1822-2 : 2010 | Identical |
DIN EN 1822-2:2011-01 | Identical |
I.S. EN 1822-2:2009 | Identical |
ONORM EN 1822-2 : 2010 | Identical |
PN EN 1822-2 : 2009 | Identical |
NEN EN 1822-2 : 2009 | Identical |
UNI EN 1822-2 : 2010 | Identical |
BS EN 1822-2:2009 | Identical |
NS EN 1822-2 : 2009 | Identical |
SS-EN 1822-2:2009 | Identical |
ISO 29463-1:2017 | High efficiency filters and filter media for removing particles from air — Part 1: Classification, performance, testing and marking |
I.S. EN 13824:2005 | STERILIZATION OF MEDICAL DEVICES - ASEPTIC PROCESSING OF LIQUID MEDICAL DEVICES - REQUIREMENTS |
09/30182875 DC : 0 | BS ISO 29463-4 - HIGH-EFFICIENCY FILTERS AND FILTER MEDIA FOR REMOVING PARTICLES FROM AIR - PART 4: TEST METHOD FOR DETERMINING THE LEAKAGE OF FILTER ELEMENTS (SCAN METHOD) |
03/317114 DC : DRAFT OCT 2003 | EN 14799 - AIR FILTERS FOR GENERAL AIR CLEANING - TERMINOLOGY |
DIN EN 1822-4:2011-01 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD) |
UNI EN 1822-3 : 2010 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA |
DIN EN 1822-5:2011-01 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS |
NF EN 1822-5 : 2010 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS |
I.S. EN 1822-5:2009 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS |
EN 1822-5:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements |
UNE-EN 1822-4:2010 | High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method) |
NF EN 1822-4 : 2010 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD) |
UNI EN 1822-4 : 2010 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD) |
NF EN 1822-3 : 2010 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA |
I.S. EN ISO 14644-3:2006 | CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 3: TEST METHODS |
BS EN ISO 16000-7:2007 | Indoor air Sampling strategy for determination of airborne asbestos fibre concentrations |
BS EN 13824:2004 | Sterilization of medical devices. Aseptic processing of liquid medical devices. Requirements |
ISO 29463-2:2011 | High-efficiency filters and filter media for removing particles in air — Part 2: Aerosol production, measuring equipment and particle-counting statistics |
BS EN 15695-2:2017 | Agricultural tractors and self-propelled sprayers. Protection of the operator (driver) against hazardous substances Filters, requirements and test procedures |
15/30329404 DC : 0 | BS EN 15695-2 - AGRICULTURAL TRACTORS AND SELF-PROPELLED SPRAYERS - PROTECTION OF THE OPERATOR (DRIVER) AGAINST HAZARDOUS SUBSTANCES - PART 2: FILTERS, REQUIREMENTS AND TEST PROCEDURES |
NF ISO 12500-3 : 2009 | FILTERS FOR COMPRESSED AIR - TEST METHODS - PART 3: PARTICULATES |
BS EN 1822-1:2009 | High efficiency air filters (EPA, HEPA and ULPA) Classification, performance testing, marking |
DIN EN 1822-1:2011-01 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING |
I.S. EN 1822-4:2009 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD) |
UNI EN 1822-1 : 2010 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING |
EN 15695-2:2017 | Agricultural tractors and self-propelled sprayers - Protection of the operator (driver) against hazardous substances - Part 2: Filters, requirements and test procedures |
ISO 29463-3:2011 | High-efficiency filters and filter media for removing particles in air — Part 3: Testing flat sheet filter media |
EN 1822-4:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method) |
BS EN 1822-3:2009 | High efficiency air filters (EPA, HEPA and ULPA) Testing flat sheet filter media |
BS EN 1822-4:2009 | High efficiency air filters (EPA, HEPA and ULPA) Determining leakage of filter elements (scan method) |
EN 1822-3:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media |
I.S. EN 1822-1:2009 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING |
BS EN ISO 14644-4:2001 | Cleanrooms and associated controlled environments Design, construction and start-up |
VDI 6300 Blatt 1:2016-05 | Genetic engineering operations in genetic engineering facilities - Guidance on safe operation of genetic engineering facilities |
VDI 2083 Blatt 3:2005-07 | Cleanroom technology - Metrology and test methods |
16/30326493 DC : 0 | BS EN ISO 14644-3 - CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 3: TEST METHODS |
08/30176852 DC : DRAFT APR 2008 | BS EN 1822-4 - HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD) |
08/30176848 DC : DRAFT APR 2008 | BS EN 1822-3 - HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA |
BS ISO 12500-3:2009 | Filters for compressed air. Test methods Particulates |
PREN 15695-2 : DRAFT 2015 | AGRICULTURAL TRACTORS AND SELF-PROPELLED SPRAYERS - PROTECTION OF THE OPERATOR (DRIVER) AGAINST HAZARDOUS SUBSTANCES - PART 2: FILTERS, REQUIREMENTS AND TEST PROCEDURES |
EN 1822-1:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking |
ISO 29463-4:2011 | High-efficiency filters and filter media for removing particles in air — Part 4: Test method for determining leakage of filter elements-Scan method |
UNE-EN 1822-3:2010 | High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media |
I.S. EN 1822-3:2009 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA |
BS EN 1822-5:2009 | High efficiency air filters (EPA, HEPA and ULPA) Determining the efficiency of filter elements |
DIN EN 1822-3:2011-01 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA |
UNI EN 1822-5 : 2010 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS |
DIN EN ISO 14644-3:2006-03 | CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 3: TEST METHODS |
ISO 16000-7:2007 | Indoor air — Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations |
BS EN 14799:2007 | Air filters for general air cleaning. Terminology |
I.S. EN 14799:2007 | AIR FILTERS FOR GENERAL AIR CLEANING - TERMINOLOGY |
UNI EN 14799 : 2008 | AIR FILTERS FOR GENERAL AIR CLEANING - TERMINOLOGY |
09/30182882 DC : 0 | BS ISO 29463-5 - HIGH-EFFICIENCY FILTERS AND FILTER MEDIA FOR REMOVING PARTICLES FROM AIR - PART 5: TEST METHOD FOR DETERMINING THE EFFICIENCY OF FILTER ELEMENTS |
07/30164823 DC : 0 | BS EN 15695-2 - AGRICULTURAL TRACTORS AND SELF-PROPELLED MACHINERY - PROTECTION AGAINST HAZARDOUS SUBSTANCES - PART 2: AIR PURIFYING DEVICES |
07/30164305 DC : 0 | BS ISO 12500-3 - FILTERS FOR COMPRESSED AIR - TEST METHODS - PART 3: PARTICULATES |
08/30176838 DC : DRAFT APR 2008 | BS EN 1822-1 - HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING |
ISO 12500-3:2009 | Filters for compressed air Test methods Part 3: Particulates |
UNE-EN 15695-2:2010 | Agricultural tractors and self-propelled sprayers - Protection of the operator (driver) against hazardous substances - Part 2: Filters, requirements and test procedures |
UNE-EN 1822-1:2010 | High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking |
ISO 29463-5:2011 | High-efficiency filters and filter media for removing particles in air Part 5: Test method for filter elements |
UNE-EN 1822-5:2010 | High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements |
ISO 14644-4:2001 | Cleanrooms and associated controlled environments — Part 4: Design, construction and start-up |
BS EN ISO 14644-3:2005 | Cleanrooms and associated controlled environments Test methods |
ISO 26802:2010 | Nuclear facilities Criteria for the design and the operation of containment and ventilation systems for nuclear reactors |
EN ISO 16000-7:2007 | Indoor air - Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations (ISO 16000-7:2007) |
EN 14799:2007 | Air filters for general air cleaning - Terminology |
EN ISO 14644-4:2001 | Cleanrooms and associated controlled environments - Part 4: Design, construction and start-up (ISO 14644-4:2001) |
EN ISO 14644-3:2005 | Cleanrooms and associated controlled environments - Part 3: Test methods (ISO 14644-3:2005) |
EN 13824:2004 | Sterilization of medical devices - Aseptic processing of liquid medical devices - Requirements |
I.S. EN 15695-2:2017 | AGRICULTURAL TRACTORS AND SELF-PROPELLED SPRAYERS - PROTECTION OF THE OPERATOR (DRIVER) AGAINST HAZARDOUS SUBSTANCES - PART 2: FILTERS, REQUIREMENTS AND TEST PROCEDURES |
11/30232479 DC : 0 | BS ISO 3857-4 - COMPRESSOR, PNEUMATIC TOOLS AND MACHINES - VOCABULARY - PART 4: AIR TREATMENT |
08/30176855 DC : DRAFT APR 2008 | BS EN 1822-5 - HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS |
NF EN 1822-1 : 2010 | HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING |
SAE AIR 4766/1 : 2011 | AIR QUALITY FOR COMMERCIAL AIRCRAFT CABIN - PARTICULATE CONTAMINANTS |
ISO 14644-3:2005 | Cleanrooms and associated controlled environments Part 3: Test methods |
BS ISO 26802:2010 | Nuclear facilities. Criteria for the design and the operation of containment and ventilation systems for nuclear reactors |
DIN EN 13824:2005-02 | STERILIZATION OF MEDICAL DEVICES - ASEPTIC PROCESSING OF LIQUID MEDICAL DEVICES - REQUIREMENTS |
EN 1822-5:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements |
VDI 3491 Blatt 1:2016-07 | Measurement of particles - Methods for generating test aerosols - Principles and overview |
VDI 3489 Blatt 2:1995-12 | Particulate matter measurement - Methods for characterizing and monitoring test aerosols - Continuous flow condensation nucleus counter |
VDI 2080:1996-04 | Measuring methods and measuring instruments for air-conditioning systems |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
ISO 14644-3:2005 | Cleanrooms and associated controlled environments Part 3: Test methods |
VDI 3489 Blatt 3:1997-03 | Particulate matter measurement - Methods of characterizing and monitoring test aerosols - Optical particle counter |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
VDI 3491 Blatt 5:1980-12 | Particulate matter measurement; generation of test aerosols by nebulization of dye-solutions with nozzle atomizers |
EN 1822-3:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media |
VDI 3491 Blatt 7:1987-12 | Particulate matter measurement; generation of test aerosols; Rapaport-Weinstock generator |
EN 1822-1:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking |
EN 1822-4:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method) |
EN 14799:2007 | Air filters for general air cleaning - Terminology |
VDI 3491 Blatt 13:1996-06 | Particulate matter measurement - Generation of test aerosols using a vibrating-orifice generator |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.