Heat exchangers - Methods of measuring the parameters necessary for establishing the performance
19-02-1997
Foreword
Introduction
1 Scope
2 Normative references
3 Definitions
3.1 Measurement of temperature
3.2 Measurement of flow-rate
3.3 Measurement of pressure
3.4 Measurement of fluid quality
3.5 General definitions
4 Sampling
4.1 Sampling frequency
4.2 Measuring sampling period
4.3 Simultaneous reading of measurement
4.4 Mean value calculation
5 Temperature measurement
5.1 Purpose
5.2 Equipment
5.2.1 Expansion thermometers
5.2.2 Resistance thermometers
5.2.3 Thermocouples
5.3 Preparations
5.3.1 Installation
5.3.2 Location
5.3.3 Static measurement error
5.3.4 Dynamic measurement error
5.3.5 Other requirements for temperature
sensor installation
5.4 Calibration
5.4.1 Purpose
5.4.2 Traceability
5.4.3 Uncertainty of calibration
5.4.4 Calibration interval
5.5 Stability
5.6 Presentation of temperature measurement
6 Measurement of flow-rate
6.1 Purpose
6.2 Equipment
6.2.1 Common measuring methods for liquids
and gas
6.2.2 Measurement methods for liquid flow-rates
6.2.3 Measurement of two-phase flow
6.3 Preparations
6.3.1 Installation
6.3.2 Location
6.3.3 Static measurement error
6.3.4 Dynamic measurement error
6.3.5 Other requirements for flow meter
installation
6.4 Calibration
6.4.1 Purpose
6.4.2 Traceability
6.4.3 Uncertainty of calibration
6.4.4 Calibration interval
6.5 Stability
6.6 Presentation of mass flow measurement
7 Measurement of pressure
7.1 Purpose
7.2 Measurement probes and pressure tappings
7.2.1 Total pressure
7.2.2 Static pressure
7.2.3 Dynamic pressure
7.2.4 Pressure drop
7.3 Equipment
7.3.1 U-tube manometer
7.3.2 Pressure transducer
7.4 Preparations
7.4.1 Installation
7.4.2 Location
7.4.3 Static measuring error
7.4.4 Dynamic measuring errors
7.4.5 Other requirements for pressure tapping
installation
7.5 Calibration
7.5.1 Purpose
7.5.2 Traceability
7.5.3 Uncertainty of calibration
7.5.4 Calibration interval
7.6 Stability
7.7 Presentation of pressure measurement
8 Fluid quality
8.1 Purpose
8.2 Determination of density
8.3 Determination of specific heat capacity/enthalpy
8.4 Determination of vapour ratio, (x)
8.5 Determination of phase state
8.6 Determination of viscosity
8.7 Determination of mass ratios
9 Requirements for peripheral equipment and media
9.1 Peripheral equipment
9.1.1 Regulating system
9.1.2 Heaters and coolers
9.1.3 Flows
9.1.4 Pressures
9.2 Media
9.2.1 Ageing
9.2.2 Filtering
10 Test record
10.1 Laboratory test and acceptance test
This European Standard specifies the methods and accuracy of measurement for temperature, pressure, fluid quality and massflow of different fluids and how to determine the pressure drops across a heat exchanger. Measurements are restricted to those necessary for establishing the performance of heat exchangers classified in prEN 247 using the fluids listed in prEN 247. This E.S. applies when reference by the various branch application standards. The specific application European Standards shall be the prime reference documents.
Committee |
CEN/TC 110
|
DevelopmentNote |
Supersedes ENV 306 (07/2004)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
GOST R EN 306 : 2011 | Identical |
NBN EN 306 : 1997 | Identical |
NF EN 306 : 1997 | Identical |
NEN EN 306 : 1997 | Identical |
NS EN 306 : 1ED 1997 | Identical |
I.S. EN 306:1997 | Identical |
PN EN 306 : 2001 | Identical |
SN EN 306 : 1997 | Identical |
UNI EN 306 : 2001 | Identical |
UNE-EN 306:1997 | Identical |
BS EN 306:1997 | Identical |
DIN EN 306:1997-07 | Identical |
I.S. EN 1148:1999 | HEAT EXCHANGERS - WATER TO WATER EXCHANGERS FOR DISTRICT HEATING - TEST PROCEDURES FOR ESTABLISHING THE PERFORMANCE DATA |
I.S. EN 1118:1999 | HEAT EXCHANGERS - REFRIGERANT COOLED LIQUID COOLERS - TEST PROCEDURES FOR ESTABLISHING THE PERFORMANCE |
DIN EN 13141-11:2015-07 | VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 11: SUPPLY VENTILATION UNITS |
UNE-EN 13141-11:2015 | Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 11: Supply ventilation units |
UNI EN 13141-7 : 2011 | VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 7: PERFORMANCE TESTING OF A MECHANICAL SUPPLY AND EXHAUST VENTILATION UNITS (INCLUDING HEAT RECOVERY) FOR MECHANICAL VENTILATION SYSTEMS INTENDED FOR SINGLE FAMILY DWELLINGS |
DIN EN 1048:2014-11 | HEAT EXCHANGERS - AIR COOLED LIQUID COOLERS ('DRY COOLERS') - TEST PROCEDURES FOR ESTABLISHING THE PERFORMANCE |
BS EN 13741:2003 | Thermal performance acceptance testing of mechanical draught series wet cooling towers |
DIN EN 13741:2004-05 | Thermal performance acceptance testing of mechanical draught series wet cooling towers |
EN 13141-11:2015 | Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 11: Supply ventilation units |
EN 13141-8:2014 | Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 8: Performance testing of un-ducted mechanical supply and exhaust ventilation units (including heat recovery) for mechanical ventilation systems intended for a single room |
DIN EN 14705:2005-10 | Heat exchangers - Method of measurement and evaluation of thermal performances of wet cooling towers; German version EN 14705:2005 |
04/30109542 DC : DRAFT FEB 2004 | EN 13141-8 - VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 8: PERFORMANCE TESTING OF UNDUCTED MECHANICAL SUPPLY AND EXHAUST VENTILATION UNITS [INCLUDING HEAT RECOVERY] FOR MECHANICAL VENTILATION SYSTEMS INTENDED FOR A SINGLE ROOM |
PREN 1048 : DRAFT 2012 | HEAT EXCHANGERS - AIR COOLED LIQUID COOLERS ('DRY COOLERS') - TEST PROCEDURES FOR ESTABLISHING PERFORMANCE |
I.S. EN 1216:1999 | HEAT EXCHANGERS - FORCED CIRCULATION AIR-COOLING AND AIR-HEATING COILS - TEST PROCEDURES FOR ESTABLISHING THE PERFORMANCE |
DIN EN 13141-8:2014-09 | Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 8: Performance testing of un-ducted mechanical supply and exhaust ventilation units (including heat recovery) for mechanical ventilation systems intended for a single room |
I.S. EN 13141-8:2014 | VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 8: PERFORMANCE TESTING OF UN-DUCTED MECHANICAL SUPPLY AND EXHAUST VENTILATION UNITS (INCLUDING HEAT RECOVERY) FOR MECHANICAL VENTILATION SYSTEMS INTENDED FOR A SINGLE ROOM |
I.S. EN 13141-7:2010 | VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 7: PERFORMANCE TESTING OF A MECHANICAL SUPPLY AND EXHAUST VENTILATION UNITS (INCLUDING HEAT RECOVERY) FOR MECHANICAL VENTILATION SYSTEMS INTENDED FOR SINGLE FAMILY DWELLINGS |
DIN EN 13141-7:2011-01 | Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 7: Performance testing of a mechanical supply and exhaust ventilation units (including heat recovery) for mechanical ventilation systems intended for single family dwellings |
I.S. EN 1048:2014 | HEAT EXCHANGERS - AIR COOLED LIQUID COOLERS ('DRY COOLERS') - TEST PROCEDURES FOR ESTABLISHING THE PERFORMANCE |
EN 13141-7:2010 | Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 7: Performance testing of a mechanical supply and exhaust ventilation units (including heat recovery) for mechanical ventilation systems intended for single family dwellings |
I.S. EN 1117:1999 | HEAT EXCHANGERS - LIQUID COOLED REFRIGERANT CONDENSERS - TEST PROCEDURES FOR ESTABLISHING THE PERFORMANCE |
08/30183867 DC : DRAFT AUG 2008 | BS EN 13141-7 - VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 7: PERFORMANCE TESTING OF A MECHANICAL SUPPLY AND EXHAUST VENTILATION UNITS (INCLUDING HEAT RECOVERY) FOR MECHANICAL VENTILATION SYSTEMS INTENDED FOR SINGLE FAMILY DWELLINGS |
I.S. ENV 1995-1-2:1994 | EUROCODE 5: DESIGN OF TIMBER STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN |
NF EN 13141-7 : 2011 | VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 7: PERFORMANCE TESTING OF A MECHANICAL SUPPLY AND EXHAUST VENTILATION UNITS (INCLUDING HEAT RECOVERY) FOR MECHANICAL VENTILATION SYSTEMS INTENDED FOR SINGLE FAMILY DWELLINGS |
EN 13741:2003 | Thermal performance acceptance testing of mechanical draught series wet cooling towers |
UNI EN 13141-8 : 2014 | VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 8: PERFORMANCE TESTING OF UN-DUCTED MECHANICAL SUPPLY AND EXHAUST VENTILATION UNITS (INCLUDING HEAT RECOVERY) FOR MECHANICAL VENTILATION SYSTEMS INTENDED FOR A SINGLE ROOM |
BS EN 13141-11:2015 | Ventilation for buildings. Performance testing of components/products for residential ventilation Supply ventilation units |
I.S. EN 13141-11:2015 | VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 11: SUPPLY VENTILATION UNITS |
UNE-EN 1048:2015 | Heat exchangers - Air cooled liquid coolers ('dry coolers') - Test procedures for establishing the performance |
BS EN 14705:2005 | Heat exchangers. Method of measurement and evaluation of thermal performances of wet cooling towers |
BS EN 1148:1999 | Heat exchangers. Water-to-water heat exchangers for district heating. Test procedures for establishing the performance data |
BS EN 1118:1999 | Heat exchangers. Refrigerant cooled liquid coolers. Test methods for establishing the performance |
BS EN 13141-8:2014 | Ventilation for buildings. Performance testing of components/products for residential ventilation Performance testing of un-ducted mechanical supply and exhaust ventilation units (including heat recovery) for mechanical ventilation systems intended for a single room |
EN 14705:2005 | Heat exchangers - Method of measurement and evaluation of thermal performances of wet cooling towers |
EN 308:1997 | Heat exchangers - Test procedures for establishing performance of air to air and flue gases heat recovery devices |
12/30269382 DC : 0 | BS EN 1048 - HEAT EXCHANGERS - AIR-COOLED LIQUID COOLERS ('DRY COOLERS') - TEST PROCEDURES FOR ESTABLISHING PERFORMANCE |
UNE-EN 13141-8:2015 | Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 8: Performance testing of un-ducted mechanical supply and exhaust ventilation units (including heat recovery) for mechanical ventilation systems intended for a single room |
BS EN 1117:1999 | Heat exchangers. Liquid-cooled refrigerant condensers. Test methods for establishing the performance |
UNE-EN 13141-7:2011 | Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 7: Performance testing of a mechanical supply and exhaust ventilation units (including heat recovery) for mechanical ventilation systems intended for single family dwellings |
BS EN 308:1997 | Heat exchangers. Test procedures for establishing the performance of air to air and flue gases heat recovery devices |
BS EN 13141-7:2010 | Ventilation for buildings. Performance testing of components/products for residential ventilation Performance testing of a mechanical supply and exhaust ventilation units (including heat recovery) for mechanical ventilation systems intended for single family dwellings |
BS EN 1216:1999 | Heat exchangers. Forced circulation air-cooling and air-heating coils. Test procedures for establishing the performance |
BS EN 1048:2014 | Heat exchangers. Air cooled liquid coolers (\'dry coolers\'). Test procedures for establishing the performance |
EN 1048:2014 | Heat exchangers - Air cooled liquid coolers ('dry coolers') - Test procedures for establishing the performance |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ISO 5221:1984 | Air distribution and air diffusion Rules to methods of measuring air flow rate in an air handling duct |
ISO 2186:2007 | Fluid flow in closed conduits — Connections for pressure signal transmissions between primary and secondary elements |
EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.