• Shopping Cart
    There are no items in your cart

EN 50121-4:2016

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus

Withdrawn date

24-10-2019

Superseded by

EN 50121-4:2016/A1:2019

Published date

23-12-2016

Sorry this product is not available in your region.

European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Description of location
5 Emission limits for apparatus
6 Immunity
Annex ZZ (informative) - Relationship between this
         European Standard and the essential
         requirements of Directive 2014/30/EU
         [2014 OJ L96] aimed to be covered
Bibliography

This European Standard applies to signalling and telecommunication apparatus that is installed inside the railway environment. Signalling and telecommunication apparatus mounted in vehicles is covered by FprEN 50121 3 2:2016, signalling and telecommunication apparatus installed inside the substation and connected to substation equipment is covered by FprEN 50121 5:2016.

This European Standard specifies limits for emission and immunity and provides performance criteria for signalling and telecommunications (S&T) apparatus (including power supply systems belonging to S&T) which may interfere with other apparatus inside the railway environment, or increase the total emissions for the railway environment and so risk causing Electro-Magnetic Interference (EMI) to apparatus outside the railway system.

The requirements specified given in this standard apply for:

—vital equipment such as interlocking or command and control;

—apparatus inside the 3 m zone;

—ports of apparatus inside the 10 m zone with connection inside the 3 m zone;

—ports of apparatus inside the 10 m zone with cable length > 30 m.

Other apparatus not covered by at least one of these given cases should be in compliance with EN 61000 6 2.

If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirement in this standard are not intended to be applicable to the intentional transmission from a radio-transmitter as defined by the ITU.

Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC related standard for radio equipment.

The standard does not specify basic personal safety requirements for apparatus such as protection against electric shock, unsafe operation, insulation co-ordination and related dielectric tests. The requirements were developed for and are applicable to this set of apparatus when operating under normal conditions. Fault conditions of the apparatus have not been taken into account.

The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified.

For products in the scope of EN 61000 3 2, EN 61000 3 3, EN 61000 3 11 or EN 61000 3 12 the requirements of those standards also apply.

These specific provisions are to be used in conjunction with the general provisions in FprEN 50121 1:2016.

The immunity and emission levels do not of themselves guarantee that the integration of apparatus will necessarily be satisfactory. The standard cannot cover all the possible configurations of the apparatus, but the test levels are sufficient to achieve satisfactory EMC in the majority of cases.

Committee
CLC/TC 9X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn
SupersededBy
Supersedes

NF EN 15437-1 : 2009 RAILWAY APPLICATIONS - AXLEBOX CONDITION MONITORING - INTERFACE AND DESIGN REQUIREMENTS - PART 1: TRACK SIDE EQUIPMENT AND ROLLING STOCK AXLEBOX
14/30297515 DC : 0 BS EN 16704-2-1 - RAILWAY APPLICATIONS - TRACK - SAFETY PROTECTION ON THE TRACK DURING WORK - PART 2-1: COMMON SOLUTIONS AND TECHNOLOGY - TECHNICAL REQUIREMENTS FOR TRACK WARNING SYSTEMS (TWS)
I.S. EN 50125-3:2003 RAILWAY APPLICATION - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 3: EQUIPMENT FOR SIGNALLING AND TELECOMMUNICATIONS
PREN 15654-1 : DRAFT 2015 RAILWAY APPLICATIONS - MEASUREMENT OF VERTICAL FORCES ON WHEELS AND WHEELSETS - PART 1: INTEROPERABLE ON-TRACK MEASUREMENT SITES FOR VEHICLES IN SERVICE
EN 50125-3 : 2003 COR 2010 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 3: EQUIPMENT FOR SIGNALLING AND TELECOMMUNICATIONS
CLC/TR 50506-2:2009 RAILWAY APPLICATIONS - COMMUNICATION, SIGNALLING AND PROCESSING SYSTEMS - APPLICATION GUIDE FOR EN 50129 - PART 2: SAFETY ASSURANCE
12/30241400 DC : 0 BS EN 15654-1 - RAILWAY APPLICATIONS - MEASUREMENT OF WHEEL AND AXLE LOADS - PART 1: INTEROPERABLE 'IN-SERVICE' RAIL VEHICLES
CEI EN 50529-1 : 2013 EMC NETWORK STANDARD - PART 1: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING TELEPHONE WIRES
15/30326124 DC : 0 BS EN 15654-1 - RAILWAY APPLICATIONS - MEASUREMENT OF VERTICAL FORCES ON WHEELS AND WHEELSETS - PART 1: INTEROPERABLE ON-TRACK MEASUREMENT SITES FOR VEHICLES IN SERVICE
BS EN 15437-1:2009 Railway applications. Axlebox condition monitoring. Interface and design requirements Track side equipment and rolling stock axlebox
13/30251582 DC : 0 BS EN 50617-2 - RAILWAYS APPLICATIONS - BASIC PARAMETERS OF TRAIN DETECTION SYSTEMS - PART 2: AXLE COUNTERS
PD CLC/TR 50506-2:2009 Railway applications. Communication, signalling and processing systems. Application guide for EN 50129 Safety assurance
AS/RISSB 7722 : 2016 EMC Management
I.S. EN 16704-2-1:2016 RAILWAY APPLICATIONS - TRACK - SAFETY PROTECTION ON THE TRACK DURING WORK - PART 2-1: COMMON SOLUTIONS AND TECHNOLOGIES - TECHNICAL REQUIREMENTS FOR TRACK WARNING SYSTEMS (TWS)
EN 50239:2018 Railway applications - Radio remote control system of traction vehicle for shunting application
BS EN 50617-1:2015 Railway applications. Technical parameters of train detection systems for the interoperability of the trans-European railway system Track circuits
I.S. EN 15437-1:2009 RAILWAY APPLICATIONS - AXLEBOX CONDITION MONITORING - INTERFACE AND DESIGN REQUIREMENTS - PART 1: TRACK SIDE EQUIPMENT AND ROLLING STOCK AXLEBOX
DD ENV 50129:1999 Railway applications. Safety related electronic systems for signalling
BS EN 50125-3:2003 Railway applications. Environmental conditions for equipment Equipment for signalling and telecommunications
UNE-EN 50121-2:2017 Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world
AS/RISSB 7505 : 2014 Railway Rolling Stock – Signal Detection Interface Signalling Detection Interface
BS EN 50121-2:2017 Railway applications. Electromagnetic compatibility Emission of the whole railway system to the outside world
I.S. EN 15654-1:2018 RAILWAY APPLICATIONS - MEASUREMENT OF VERTICAL FORCES ON WHEELS AND WHEELSETS - PART 1: ON-TRACK MEASUREMENT SITES FOR VEHICLES IN SERVICE
PREN 50129 : DRAFT 2000 RAILWAY APPLICATIONS - SAFETY RELATED ELECTRONIC SYSTEMS FOR SIGNALLING
I.S. EN 50239:2018 RAILWAY APPLICATIONS - RADIO REMOTE CONTROL SYSTEM OF TRACTION VEHICLE FOR SHUNTING APPLICATION
UNI EN 15437-1 : 2009 RAILWAY APPLICATIONS - AXLEBOX CONDITION MONITORING - INTERFACE AND DESIGN REQUIREMENTS - PART 1: TRACK SIDE EQUIPMENT AND ROLLING STOCK AXLEBOX
BS EN 50617-2:2015 Railway Applications. Technical parameters of train detection systems for the interoperability of the trans-European railway system Axle counters
UNE-EN 50617-1:2015 Railway applications - Technical parameters of train detection systems for the interoperability of the trans-European railway system - Part 1: Track circuits
CEI EN 50125-3 : 2004 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 3: EQUIPMENT FOR SIGNALLING AND TELECOMMUNICATIONS
07/30137492 DC : 0 EN 15654-1 - RAILWAY APPLICATIONS - MEASUREMENT OF WHEEL AND AXLE LOADS - PART 1: INTEROPERABLE 'IN-SERVICE' RAIL VEHICLES
BS EN 16704-2-1:2016 Railway applications. Track. Safety protection on the track during work Common solutions and technologies. Technical requirements for Track Warning Systems (TWS)
DIN EN 15437-1:2010-06 Railway applications - Axlebox condition monitoring - Interface and design requirements - Part 1: Track side equipment and rolling stock axlebox
16/30208484 DC : 0 BS EN 15654-2 - RAILWAY APPLICATIONS - MEASUREMENT OF VERTICAL FORCES ON WHEELS AND WHEELSETS - PART 2: TEST IN WORKSHOP FOR NEW, MODIFIED AND MAINTAINED VEHICLES
UNE-EN 15437-1:2010 Railway applications - Axlebox condition monitoring - Interface and design requirements - Part 1: Track side equipment and rolling stock axlebox
I.S. EN 50617-2:2015 RAILWAY APPLICATIONS - TECHNICAL PARAMETERS OF TRAIN DETECTION SYSTEMS FOR THE INTEROPERABILITY OF THE TRANS-EUROPEAN RAILWAY SYSTEM - PART 2: AXLE COUNTERS
S.R. CLC/TR 50506-2:2009 RAILWAY APPLICATIONS - COMMUNICATION, SIGNALLING AND PROCESSING SYSTEMS - APPLICATION GUIDE FOR EN 50129 - PART 2: SAFETY ASSURANCE
I.S. EN 50617-1:2015 RAILWAY APPLICATIONS - TECHNICAL PARAMETERS OF TRAIN DETECTION SYSTEMS FOR THE INTEROPERABILITY OF THE TRANS-EUROPEAN RAILWAY SYSTEM - PART 1: TRACK CIRCUITS
17/30326406 DC : 0 BS EN 17168 - RAILWAY APPLICATIONS - PLATFORM BARRIER SYSTEMS
EN 15437-1:2009 Railway applications - Axlebox condition monitoring - Interface and design requirements - Part 1: Track side equipment and rolling stock axlebox
EN 16704-2-1:2016 Railway applications - Track - Safety protection on the track during work - Part 2-1: Common solutions and technologies - Technical requirements for Track Warning Systems (TWS)
BS EN 50529-1:2010 EMC network standard Wire-line telecommunications networks using telephone wires
16/30340728 DC : 0 BS EN 50121-2 - RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD
I.S. EN 50529-1:2010 EMC NETWORK STANDARD - PART 1: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING TELEPHONE WIRES
UNE-EN 16704-2-1:2017 Railway applications - Track - Safety protection on the track during work - Part 2-1: Common solutions and technologies - Technical requirements for Track Warning Systems (TWS)
PREN 50617-2 : DRAFT 2013 RAILWAYS APPLICATIONS - BASIC PARAMETERS OF TRAIN DETECTION SYSTEMS - PART 2: AXLE COUNTERS
00/241939 DC : DRAFT MAY 2000 PREN 50129 - RAILWAY APPLICATIONS - SAFETY RELATED ELECTRONIC SYSTEMS FOR SIGNALLING
I.S. EN 50121-2:2017 RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD
EN 50121-2:2017 Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world
PREN 50121-2 : DRAFT 2016 RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD
EN 15654-1:2018 Railway applications - Measurement of vertical forces on wheels and wheelsets - Part 1: On-track measurement sites for vehicles in service
EN 50529-1:2010 EMC NETWORK STANDARD - PART 1: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING TELEPHONE WIRES
EN 50617-1:2015 Railway applications - Technical parameters of train detection systems for the interoperability of the trans-European railway system - Part 1: Track circuits
EN 50617-2:2015/AC:2016 RAILWAY APPLICATIONS - TECHNICAL PARAMETERS OF TRAIN DETECTION SYSTEMS FOR THE INTEROPERABILITY OF THE TRANS-EUROPEAN RAILWAY SYSTEM - PART 2: AXLE COUNTERS

IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
EN 50121-3-2:2016 Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 61000-3-11:2000 Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current
EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
EN 50121-1:2017 Railway applications - Electromagnetic compatibility - Part 1: General
CISPR 16-2-1:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
EN 61000-6-4:2007/A1:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
EN 61000-3-12:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011)
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 55016-2-1:2014/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-1: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-2-1:2014/A1:2017)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.