EN 54-5:2017
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
28-02-2021
01-02-2017
European foreword
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Product characteristics
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of
performance (AVCP)
7 Classification
8 Marking, labelling and packaging
Annex A (normative) - Heat tunnel for response
time and response temperature measurements
Annex B (informative) - Information concerning the
construction of the heat tunnel
Annex C (informative) - Derivation of upper and lower
limits of response times
Annex D (informative) - Apparatus for impact test
Annex E (informative) - Data supplied with point
heat detectors
Annex ZA (informative) - Clauses of this European
Standard addressing the provisions of the
EU Construction Products Regulation
Bibliography
This European Standard specifies the requirements, test methods and performance criteria for point heat detectors intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54-1:2011). This European standard provides for the evaluation of conformity (EoC) of point heat detectors to this EN. For other types of heat detector, or for detectors intended for use in other environments, this standard should only be used for guidance.Heat detectors with special characteristics and developed for specific risks are not covered by this standard.
Committee |
CEN/TC 72
|
DevelopmentNote |
Supersedes EN 54-6 and EN 54-8. (03/2001) Supersedes PREN 54-5. (02/2017)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NBN EN 54-5 : 2001 AMD 1 2002 | Identical |
ÖNORM EN 54-5:2018 | Identical |
NS EN 54-5 : 2017 | Identical |
NFS 61 952 : 77 AMD 1 1989 | Identical |
SNV DIN EN 54-5 : 1989 | Identical |
NF EN 54-5 : 2017 | Identical |
I.S. EN 54-5:2017 | Identical |
UNI EN 54-5 : 2003 | Identical |
PN EN 54-5 : 2017 | Identical |
SN EN 54-5:2017 | Identical |
DIN EN 54-5:2001-03 | Identical |
UNI EN 54-5:2018 | Identical |
ONORM EN 54-5 : 2017 | Identical |
NEN EN 54-5 : 2017 | Identical |
DS EN 54-5 : 2017 | Identical |
UNE-EN 54-5:2001 | Identical |
BS EN 54-5 : 2017 | Identical |
DIN EN 54-5:2018-10 | Identical |
PNE-EN 54-5 | Identical |
NBN S 21 105 : 1987 | Identical |
BS 5445-5:1977 | Identical |
BS 5445-8:1984 | Components of automatic fire detection systems Specification for high temperature heat detectors |
BS EN 54-31 : 2014 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS |
I.S. EN 12101-2:2017 | SMOKE AND HEAT CONTROL SYSTEMS - PART 2: NATURAL SMOKE AND HEAT EXHAUST VENTILATORS |
DD CEN/TS 54-14:2004 | Fire detection and fire alarm systems Guidelines for planning, design, installation, commissioning, use and maintenance |
BS EN 12101-2:2017 | Smoke and heat control systems Natural smoke and heat exhaust ventilators |
EN 12101-2:2017 | Smoke and heat control systems - Part 2: Natural smoke and heat exhaust ventilators |
MIL-DTL-32525 Base Document:2016 | MAGAZINE, PORTABLE (SHIPBOARD) |
I.S. EN CLC TS 50398:2003 | ALARM SYSTEMS - COMBINED AND INTEGRATED ALARM SYSTEMS - GENERAL REQUIREMENTS |
DD CEN/TS 14816:2008 | Fixed firefighting systems. Water spray systems. Design and installation |
I.S. EN 54-29:2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS |
05/30117311 DC : 0 | EN 54-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS AND SYSTEM REQUIREMENTS |
11/30240275 DC : 0 | BS EN 54-22 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 22: RESETTABLE LINE TYPE HEAT DETECTORS |
DIN EN 54-29:2015-06 | Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors |
11/30249544 DC : 0 | BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE |
03/102595 DC : 0 | BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATION AND MAINTENANCE |
04/30119106 DC : DRAFT AUG 2004 | EN 14972 - FIXED FIREFIGHTING SYSTEMS - WATERMIST SYSTEMS - DESIGN AND INSTALLATION |
PREN 50553 : DRAFT 2010 | RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
CEN/TS 54-14:2004 | Fire detection and fire alarm systems - Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance |
IEC TR 61831:2011 | On-line analyser systems - Guide to design and installation |
I.S. EN 14600:2005 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
12/30256417 DC : 0 | BS EN 54-31 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS |
PD IEC/TR 61831:2011 | On-line analyser systems. Guide to design and installation |
17/30363842 DC : 0 | BS ISO 21927-2 - SMOKE AND HEAT CONTROL SYSTEMS - PART 2: SPECIFICATION FOR NATURAL SMOKE AND HEAT EXHAUST VENTILATORS |
BS EN 54-25:2008 | Fire detection and fire alarm systems Components using radio links |
BS EN 54-30:2015 | Fire detection and fire alarm systems Multi-sensor fire detectors. Point detectors using a combination of carbon monoxide and heat sensors |
BS EN 14600:2005 | Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification |
BS EN 14637:2007 | Building hardware. Electrically controlled hold-open systems for fire/smoke door assemblies. Requirements, test methods, application and maintenance |
UNI EN 14600 : 2006 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
07/30164493 DC : 0 | BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATIONS AND MAINTENANCE |
11/30240441 DC : 0 | BS EN 54-28 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESET TABLE LINE TYPE HEAT DETECTORS |
07/30158994 DC : 0 | BS EN 54-22 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 22: LINE TYPE HEAT DETECTORS |
06/30117299 DC : 0 | BS EN 54-15 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 15: POINT DETECTORS USING A COMBINATION OF DETECTED FIRE PHENOMENA |
UNI EN 54-25 : 2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
I.S. CEN TS 54-14:2004 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 14: GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE |
I.S. EN 54-30:2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS |
PREN 54-29 : DRAFT 2009 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS |
PREN 54-22 : DRAFT 2011 | FIRE DETECTION AND FIRE ALARM SYSTEM - PART 22: RESETTABLE LINE TYPE HEAT DETECTORS |
I.S. EN 54-25:2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
EN 54-29:2015 | Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
EN 14637:2007 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
EN 54-31:2014+A1:2016 | Fire detection and fire alarm systems - Part 31: Multi-sensor fire detectors - Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors |
EN 54-30:2015 | Fire detection and fire alarm systems - Part 30: Multi-sensor fire detectors - Point detectors using a combination of carbon monoxide and heat sensors |
09/30208451 DC : 0 | BS EN 54-29 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS |
UNI CEN/TS 14816 : 2009 | FIXED FIREFIGHTING SYSTEMS - WATER SPRAY SYSTEMS - DESIGN, INSTALLATION AND MAINTENANCE |
09/30195206 DC : 0 | BS EN 54-30 - FIRE DETECTION AND ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS |
10/30216933 DC : 0 | BS EN 50553 - RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
DIN EN 54-30:2015-11 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS |
BS EN 54-29:2015 | Fire detection and fire alarm systems Multi-sensor fire detectors. Point detectors using a combination of smoke and heat sensors |
00/104442 DC : DRAFT JUNE 2000 | PREN 13916 - FIRE RESISTING DOORSETS - REQUIREMENTS AND CLASSIFICATION |
03/317852 DC : 0 | BS EN 14816 - FIXED FIREFIGHTING SYSTEMS - WATER SPRAY SYSTEMS - DESIGN AND INSTALLATION |
I.S. EN 54-31:2014 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS |
DIN EN 54-25:2015-10 (Draft) | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
S.R. CEN TS 14816:2008 | FIXED FIREFIGHTING SYSTEMS - WATER SPRAY SYSTEMS - DESIGN, INSTALLATION AND MAINTENANCE |
CEN/TS 14816:2008 | Fixed firefighting systems - Water spray systems - Design, installation and maintenance |
DIN EN 14600:2006-03 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
DIN EN 14637:2008-01 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.