• Shopping Cart
    There are no items in your cart

EN 60076-10:2016

Current

Current

The latest, up-to-date edition.

Power transformers - Part 10: Determination of sound levels

Published date

11-11-2016

Sorry this product is not available in your region.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Sound power for different loading conditions
5 Sound level measurement specification
6 Instrumentation, calibration and accuracy
7 Principal radiating surface
8 Prescribed contour
9 Microphone positions
10 Calculation of the measurement surface area
11 Sound measurement
12 Determination of sound power level by calculation
13 Logarithmic addition and subtraction of individual
   sound levels
14 Far-field calculations for distances larger than 30 m
15 Presentation of results
Annex A (informative) - Narrow-band and time-synchronous
        measurements
Annex B (informative) - Typical report of sound level
        determination
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publication

IEC 60076-10:2016 defines sound pressure and sound intensity measurement methods from which sound power levels of transformers, reactors and their associated cooling devices are determined. The methods are applicable to transformers, reactors and their cooling devices - either fitted to or separate from the transformer - as covered by the IEC 60076 and IEC 61378 series. This standard is primarily intended to apply to measurements made at the factory. Conditions on-site can be very different because of the proximity of objects, including other transformers. Nevertheless, this standard is applied to the extent possible for on site measurements. This edition includes the following significant technical changes with respect to the previous edition:- additional useful definitions introduced;- definition of distribution type transformers introduced for the purpose this standard;- new clause for sound level measurement specification introduced;- requirement for 1/3 octave band measurements introduced for transformers other than distribution type transformers;- standard measurement distance changed from 0,3 m to 1 m for transformers other than distribution type transformers;- height of measurement surface is now clearly defined to count from the reflecting plane;- measurement surface formula unified;- correction criteria for intensity method introduced;- rules for sound measurements on dry-type reactors introduced;- figures revised;- new informative test report templates introduced (Annex B);- IEC 60076-10-1 (application guide) revised in parallel providing worthwhile information for the use of this standard.

Committee
CLC/TC 14
DevelopmentNote
Supersedes EN 60551 (09/2001)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

I.S. EN 50327:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
UNE-EN 50541-1:2012 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
BS EN 61287-1:2014 Railway applications. Power converters installed on board rolling stock Characteristics and test methods
BS EN 60076-6:2008 Power transformers Reactors
I.S. EN 60076-11:2004 POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS
I.S. EN 62271-212:2017 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS)
UNE-EN 61287-1:2015 Railway applications - Power converters installed on board rolling stock - Part 1: Characteristics and test methods
UNE-EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
BS EN 62271-202:2014 High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation
EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
EN 62271-202:2014/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014)
BS EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3150 kVA, with highest voltage for equipment not exceeding 36 kV General requirements
04/30117386 DC : DRAFT JUL 2004 EN 334 - GAS PRESSURE REGULATORS FOR INLET PRESSURES UP TO 100 BAR
I.S. EN 50299:2004 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72.5 KV TO 550 KV
I.S. EN 61287-1:2014 RAILWAY APPLICATIONS - POWER CONVERTERS INSTALLED ON BOARD ROLLING STOCK - PART 1: CHARACTERISTICS AND TEST METHODS
I.S. EN 62271-202:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION
UNE-EN 50216-12:2011 Power transformer and reactor fittings - Part 12: Fans
EN 50216-12:2011 Power transformer and reactor fittings - Part 12: Fans
I.S. EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
NF EN 50541-1 : 2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
CEI EN 50541-1 : 2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
BS EN 50327:2003 Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups
PREN 50541-1 : DRAFT 2009 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
UNE-EN 62271-202:2015 High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation
EN 50532:2010 Compact Equipment Assembly for Distribution Substations (CEADS)
09/30211604 DC : 0 BS EN 50541-1 - THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
BS EN 50216-12:2011 Power transformer and reactor fittings Fans
I.S. EN 50532:2010 COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
BS EN 60076-11:2004 Power transformers Dry-type transformers
BS EN 60076-1:2011 Power transformers General
BS EN 60310:2016 Railway applications. Traction transformers and inductors on board rolling stock
I.S. EN 62864-1:2016 RAILWAY APPLICATIONS - ROLLING STOCK - POWER SUPPLY WITH ONBOARD ENERGY STORAGE SYSTEM - PART 1: SERIES HYBRID SYSTEM
CEI EN 60076-1 : 2015 POWER TRANSFORMERS - PART 1: GENERAL
I.S. EN 50541-1:2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
CEI EN 60076-6 : 2015 POWER TRANSFORMERS - PART 6: REACTORS
UNE-EN 62864-1:2017 Railway applications - Rolling stock - Power supply with onboard energy storage system - Part 1: Series hybrid system
I.S. EN 60076-6:2008 POWER TRANSFORMERS - PART 6: REACTORS
BS EN 62271-212:2017 High-voltage switchgear and controlgear Compact Equipment Assembly for Distribution Substation (CEADS)
BS EN 50532:2010 Compact equipment assembly for distribution substations (CEADS)
UNE-EN 60076-1:2013 Power transformers - Part 1: General
09/30202403 DC : 0 BS EN 50532 - COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
UNE-EN 50532:2011 Compact Equipment Assembly for Distribution Substations (CEADS)
CEI EN 60076-11 : 2006 POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS
I.S. EN 60310:2016 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK
I.S. EN 50216-12:2011 POWER TRANSFORMER AND REACTOR FITTINGS - PART 12: FANS
EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
EN 61287-1:2014/AC:2014 RAILWAY APPLICATIONS - POWER CONVERTERS INSTALLED ON BOARD ROLLING STOCK - PART 1: CHARACTERISTICS AND TEST METHODS (IEC 61287-1:2014)
EN 60076-6:2008 Power transformers - Part 6: Reactors
EN 62864-1:2016 Railway applications - Rolling stock - Power supply with onboard energy storage system - Part 1: Series hybrid system
EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
EN 60310:2016/AC:2018-03 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018)

IEC 61672-2:2013+AMD1:2017 CSV Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests
ISO 3382-2:2008 Acoustics Measurement of room acoustic parameters Part 2: Reverberation time in ordinary rooms
EN 61043:1994 Electroacoustics - Instruments for the measurement of sound intensity - Measurement with pairs of pressure sensing microphones
EN 61672-2:2013/A1:2017 ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS (IEC 61672-2:2013/A1:2017)
ISO 9614-1:1993 Acoustics — Determination of sound power levels of noise sources using sound intensity — Part 1: Measurement at discrete points
IEC 61043:1993 Electroacoustics - Instruments for the measurement of sound intensity - Measurements with pairs of pressure sensing microphones
ISO 9614-2:1996 Acoustics — Determination of sound power levels of noise sources using sound intensity — Part 2: Measurement by scanning
IEC 60076-8:1997 Power transformers - Part 8: Application guide
ISO 3746:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Survey method using an enveloping measurement surface over a reflecting plane
EN 61672-1:2013 Electroacoustics - Sound level meters - Part 1: Specifications
EN ISO 3746:2010 Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane (ISO 3746:2010)
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 60076-6:2007 Power transformers - Part 6: Reactors
EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
EN ISO 9614-2:1996 Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 2: Measurement by scanning (ISO 9614-2:1996)
EN ISO 9614-1:2009 Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 1: Measurement at discrete points (ISO 9614-1:1993)
IEC 60076-10-1:2016 Power transformers - Part 10-1: Determination of sound levels - Application guide

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.