EN 60383-1:1996/A11:1999
Current
The latest, up-to-date edition.
INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
08-10-1999
INTRODUCTION
Section 1: General
1 Scope and object
2 Normative references
3 Definitions
3.1 Insulator string
3.2 Pin insulator
3.3 Line post insulator
3.4 Traction insulator
3.5 Lot
3.6 Flashover
3.7 Dry lightning impulse withstand voltage
3.8 50% dry lightning impulse flashover voltage
3.9 Wet power-frequency withstand voltage
3.10 Electromechanical failing load
3.11 Mechanical failing load
3.12 Puncture voltage
3.13 Creepage distance
3.14 Displacements
3.15 Short standard string
3.16 Specified characteristics
Section 2: Insulators
4 Classification, types of insulators and insulating
materials
4.1 Insulator classes
4.2 Insulator types
4.3 Insulating materials
5 Identification of insulators
Section 3: Classification of tests, sampling rules and
procedures
6 Classification of tests
6.1 Type tests
6.2 Sample tests
6.3 Routine tests
7 Quality assurance
8 Procedures for type and sample tests
8.1 Insulator selection for type tests
8.2 Sampling rules and procedures for sample tests
8.3 Re-test procedure for sample tests
Section 4: Test procedures for electrical tests
9 General requirements for high voltage tests
10 Standard atmospheric conditions and correction factors
10.1 Standard reference atmosphere
10.2 Correction factors for atmospheric conditions
11 Artificial rain parameters for wet tests
12 Mounting arrangements for electrical tests
13 Lightning impulse voltage tests (type test)
13.1 Test procedure
13.2 Acceptance criteria
14 Wet power-frequency voltage tests (type test)
14.1 Test procedure
14.2 Acceptance criteria
15 Puncture withstand test (sample test, for class B
insulators only)
15.1 Power-frequency puncture withstand test
15.2 Impulse overvoltage puncture withstand test
16 Routine electrical test (only on class B insulators
of ceramic material or annealed glass)
Section 5: Test procedures for mechanical and other tests
17 Verification of the dimensions (type and sample test)
18 Electromechanical failing load test (type and sample
test)
18.1 Test procedure
18.2 Acceptance criteria
19 Mechanical failing load test (type and sample test)
19.1 Test procedure for pin and line post insulators
19.2 Test procedure for string insulator units
19.3 Acceptance criteria for pin insulators
19.4 Acceptance criteria for string insulator units
and line post insulators
20 Thermal-mechanical performance test (type test)
20.1 Test procedure
20.2 Acceptance criteria
21 Verification of the axial, radial and angular
displacements (sample test)
21.1 Test procedure
21.2 Acceptance criteria for cap and pin insulators
21.3 Acceptance criteria for long rod insulators
22 Verification of the locking system (sample test)
22.1 Conformity of the locking device
22.2 Verification of locking
22.3 Position of the locking device
22.4 Procedure for the operation test
22.5 Acceptance criteria for the operation test
23 Temperature cycle test (sample test)
23.1 Test procedure for string insulator units,
pin insulators and line post insulators composed
of ceramic material
23.2 Test procedure for string insulator units,
pin insulators and line post insulators composed
of annealed glass
23.3 Special test procedure for insulators with thick
sections or very large insulators
23.4 Complementary specifications
23.5 Acceptance criteria
24 Thermal shock test (sample test)
24.1 Test procedure
24.2 Acceptance criteria
25 Porosity test (sample test)
25.1 Test procedure
25.2 Acceptance criteria
26 Galvanizing test (sample test)
26.1 Test procedures
26.2 Acceptance criteria
27 Routine visual inspection
27.1 Insulators with ceramic insulating parts
27.2 Insulators with glass insulating parts
28 Routine mechanical test
28.1 Routine mechanical test on line post insulators
28.2 Routine mechanical test on string insulator units
29 Mounting arrangements for tests on pin insulators
29.1 Standard mounting arrangement for electrical
tests
29.2 Mounting arrangements for electrical tests
reproducing service conditions
29.3 Mounting arrangement for the mechanical failing
load test
Section 7: Line post Insulators
30 Coefficient for statistical analysis of the test
results on line post insulators
30.1 Coefficient for type tests
30.2 Coefficients for sample tests
31 Mounting arrangements for tests on line post
insulators
31.1 Standard mounting arrangement for electrical tests
31.2 Mounting arrangements for electrical tests
reproducing service conditions
31.3 Mounting arrangement for the mechanical failing
load test
Section 8: String Insulator units
32 Prescriptions concerning type tests on string insulators
32.1 Electrical type tests on string insulators
32.2 Mechanical type tests
33 Coefficients for statistical analysis of the test
results on string insulators
33.1 Coefficient for type tests
33.2 Coefficients for sample tests
34 Mounting arrangements for electrical tests on string
insulator units
Section 9: Insulators for overhead electric traction lines
35 Mounting arrangements for electrical tests on insulators
for overhead electric traction lines
35.1 Standard mounting arrangement
35.2 Mounting arrangement representing service conditions
Figures
Annexes
A Method of comparison of the results of electromechanical
or mechanical type and sample tests
B Illustration of the mechanical and electromechanical or
mechanical type and sample tests
C List of normative documents given for information
ZA Normative references to international publications
with their corresponding European publications
ZA (informative) A-deviations
Applicable to insulators of ceramic material or glass to be used on a.c. overhead power and traction lines, having a nominal voltage more than 1000 V and a frequency not in excess of 100 Hz. Also applicable to insulators to be used on d.c. overhead electric traction lines.
Committee |
SR 36B
|
DocumentType |
Test Method
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
UNE-EN 60383-1:1997 | Identical |
UNE-EN 60383-1/A11:2000 | Identical |
CEI EN 60383-1/A11:2000 | Identical |
SN EN 60383-1 : 1996 AMD 11 1999 | Identical |
NEN EN IEC 60383-1 : 1997 AMD 11 1999 | Identical |
I.S. EN 60383-1:1999 | Identical |
NBN EN 60383-1 : 1997 AMD 1 2000 | Identical |
BS EN 60383-1:1998 | Identical |
IEC 60383-1:1993 | Identical |
PN EN 60383-1 : 2005 | Identical |
DIN EN 60383-1 : 97 COR 1 2001 | Identical |
NF EN 60383-1 : 97 AMD 11 2001 | Identical |
VDE 0446-1 : 97 COR 1 2001 | Identical |
DS EN 60383-1 : 1997 AMD 11 2004 | Identical |
UNE-EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
CEI EN 61109 : 2009 | INSULATORS FOR OVERHEAD LINES - COMPOSITE SUSPENSION AND TENSION INSULATORS FOR A/C/ SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
CEI EN 60437 : 1998 | RADIO INTERFERENCE TEST ON HIGH-VOLTAGE INSULATORS |
UNE-EN 50341-1:2017 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
CEI EN 61952 : 2009 | INSULATORS FOR OVERHEAD LINES - COMPOSITE LINE POST INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
I.S. EN 60437:1999 | RADIO INTERFERENCE TEST ON HIGH-VOLTAGE INSULATORS |
BS EN 61109:2008 | Insulators for overhead lines. Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1000 V. Definitions, test methods and acceptance criteria |
BS EN 61952:2008 | Insulators for overhead lines. Composite line post insulators for A.C. systems with a nominal voltage greater than 1000 V. Definitions, test methods and acceptance criteria |
15/30298489 DC : 0 | BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
BS EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications |
EN 61952:2008 | Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
EN 60437:1997 | Radio interference test on high-voltage insulators |
BS EN 61467:2008 | Insulators for overhead lines. Insulator strings and sets for lines with a nominal voltage greater than 1000 V. AC power arc tests |
PREN 50124-1 : DRAFT 2015 | RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
CEI EN 60433 : 1999 | INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV CERAMIC INSULATORS FOR A.C. SYSTEMS CHARACTERISTICS OF INSULATOR UNITS OF THE LONG ROD TYPE |
EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
I.S. EN 50124-1:2017 | RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
EN 60433:1998 | Insulators for overhead lines with a nominal voltage above 1 kV - Ceramic insulators for a.c. systems - Characteristics of insulator units of the long rod type |
BS EN 60433:1999 | Insulators for overhead lines with a nominal voltage above 1 kV. Ceramic insulators with a.c. systems. Characteristics of insulator units of the long rod type |
I.S. EN 61211:2005 | INSULATORS OF CERAMIC MATERIAL OR GLASS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - IMPULSE PUNCTURE TESTING IN AIR |
I.S. EN 50341-1:2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
CEI EN 50341-1 : 2013 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
12/30260570 DC : 0 | BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
BS EN 60437:1998 | Radio interference test on high-voltage insulators |
BS EN 61211:2005 | Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1000 V. Impulse puncture testing in air |
I.S. EN 61952:2008 | INSULATORS FOR OVERHEAD LINES - COMPOSITE LINE POST INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
I.S. EN 61109:2008 | INSULATORS FOR OVERHEAD LINES - COMPOSITE SUSPENSION AND TENSION INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
PREN 50341-1 : DRAFT 2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
BS EN 50124-1:2017 | Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment |
I.S. EN 60433:1998 | INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC INSULATORS FOR A.C. SYSTEMS - CHARACTERISTICS OF INSULATOR UNITS OF THE LONG ROD TYPE |
EN 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |
EN 61211:2005 | Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1 000 V - Impulse puncture testing in air |
EN 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 60305:1995 | Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for a.c. systems - Characteristics of insulator units of the cap and pin type |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
ISO 1463:2003 | Metallic and oxide coatings Measurement of coating thickness Microscopical method |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
IEC 60720:1981 | Characteristics of line post insulators |
ISO 1459:1973 | Metallic coatings — Protection against corrosion by hot dip galvanizing — Guiding principles |
IEC 60372:1984 | Locking devices for ball and socket couplings of string insulator units - Dimensions and tests |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
ISO 1460:1992 | Metallic coatings Hot dip galvanized coatings on ferrous materials Gravimetric determination of the mass per unit area |
IEC 60433:1998 | Insulators for overhead lines with a nominal voltage above 1 000 V - Ceramic insulators for a.c. systems - Characteristics of insulator units of the long rod type |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60120:1984 | Dimensions of ball and socket couplings of string insulator units |
ISO 2064:1996 | Metallic and other inorganic coatings — Definitions and conventions concerning the measurement of thickness |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.