• There are no items in your cart

EN 60947-5-9:2007

Current

Current

The latest, up-to-date edition.

Low-voltage switchgear and controlgear - Part 5-9: Control circuit devices and switching elements - Flow rate switches

Published date

30-11-2007

Sorry this product is not available in your region.

FOREWORD
1 General
  1.1 Scope and object
  1.2 Normative references
2 Terms and definitions
  2.1 Basic definitions
  2.2 Characteristics of a flow rate switch
  2.3 Delay times
3 Classification
  3.1 General
  3.2 Classification according to sensing means
  3.3 Classification according to the construction form
  3.4 Classification according to the switching
      element function
  3.5 Classification according to the type of output
  3.6 Classification according to the method of connection
4 Characteristics
  4.1 Summary of characteristics
  4.2 Operating conditions
  4.3 Rated and limiting values for the flow rate switch
  4.4 Utilization categories for the switching element
5 Product information
  5.1 Nature of information
  5.2 Marking
  5.3 Instruction for installation, operation and
      maintenance
6 Normal service, mounting and transport conditions
  6.1 Normal service conditions
  6.2 Conditions during transport and storage
  6.3 Mounting
  6.4 Indicating means
7 Constructional and performance requirements
  7.1 Constructional requirements
  7.2 Performance requirements
  7.3 Shock and vibration
8 Tests
  8.1 Kinds of tests
  8.2 Compliance with constructional requirements
  8.3 Performance
  8.4 Verification of set point and delay times
  8.5 Verification of the electromagnetic compatibility
  8.6 Test results and test report
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications
Annex ZZ (informative) Coverage of Essential Requirements
                       of EC Directives

This part of IEC 60947 applies to flow rate switches that sense the rate of flow of a gas, a liquid or a granular solid. These switches change their output state if a pre-set value for the speed of flow is exceeded. These flow rate switches are self-contained, have semiconductor switching element(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz a.c. or 300 V d.c.

Committee
CLC/TC 121A
DevelopmentNote
To be read in conjunction with EN 60947-1 and EN 60947-5-2. (01/2008)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

EN 303 446-2 : 1.1.0 DRAFT ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 2: SPECIFIC CONDITIONS FOR EQUIPMENT INTENDED TO BE USED IN INDUSTRIAL LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU

EN 60446:2007 Basic and safety principles for man-machine interface, marking and identification - Identification of conductors by colours or alphanumerics
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
EN 60947-1:2007/A2:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014)
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 60947-5-2:2007/A1:2012 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-2: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - PROXIMITY SWITCHES (IEC 60947-5-2:2007/A1:2012)
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 60947-5-2:2007+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches
EN 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
EN 61000-4-13:2002/A2:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015)
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.