1 Scope
2 Normative references
3 Terms and definitions
4 General requirements for all types of protection
4.1 Access for inspection
4.2 Associated equipment located in non-hazardous areas
4.3 Segregation
4.4 Electrical rating
4.5 Protection from mechanical damage and environmental injury
4.6 Documentation
4.7 Qualifications of personnel
4.8 Additional considerations
4.9 Prevention of explosion
5 Area classification
6 Selection of electrical apparatus
6.1 Permitted apparatus
6.2 Selection according to dust characteristics and zones
6.3 Selection according to temperature
6.4 Selection of apparatus
7 Protection from dangerous (incendive) sparking
7.1 Danger from live parts
7.2 Danger from exposed and extraneous conductive parts
7.3 Potential equalization
7.4 Static electricity
7.5 Electromagnetic radiation
7.6 Lightning protection
7.7 Cathodically protected metallic parts
8 Electrical protection
8.1 General
8.2 Location of protection and control equipment
8.3 Resetting of short-circuit and earth-fault protection
devices
8.4 Protection of rotating electrical machinery
8.5 Loss of supply phase
8.6 Transformer protection
9 Emergency switch-off and electrical isolation
9.1 Emergency switch-off
9.2 Electrical isolation
10 Wiring systems
10.1 General
10.2 Entries for cable and conduit
10.3 Accessories
10.4 Course of wiring
10.5 Barriers
10.6 Flexible connection
10.7 Cable entries
10.8 Unauthorized methods
10.9 Telecommunications circuits
10.10 Unused openings
11 Plugs and socket outlets
11.1 General
11.2 Mounting
11.3 Location
12 Additional requirements for type of protection "Ex tD"
12.1 Practices A and B
12.2 Practice A
12.3 Practice B
12.4 Motors supplied at varying frequency and voltages
13 Additional requirements for type of protection "pD"
13.1 Sources of protective gas
13.2 Automatic switch-off
13.3 Alarm
13.4 Common source of protective gas
13.5 Switching on electrical supply
13.6 Motors supplied at varying frequency and voltages
14 Additional requirements for type of protection "iD"
15 Additional requirements for type of protection "mD"
16 Inspection of installation
16.1 General
16.2 Testing
Annex A (informative) Examples of dust layers of excessive
thickness
Annex B (normative) Frictional sparking risks with light
metals and their alloys
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Bibliography
Specifies general requirements, additional to those required for basic electrical safety, for the selection of electrical apparatus and instruments and associated equipment, and for the installation of electrical apparatus to ensure safe use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. The application of electrical apparatus in atmospheres which may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protective measures.
Committee |
CLC/TC 31
|
DevelopmentNote |
Together with EN 61241-17, it supersedes EN 50281-1-2 (05/2005)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
DIN EN 61241-14 : 2005 | Identical |
NF EN 61241-14 : 2004 | Identical |
IEC 61241-14:2004 | Identical |
NBN EN 61241-14 : 2005 | Identical |
NEN EN IEC 61241-14 : 2004 | Identical |
I.S. EN 61241-14:2004 | Identical |
PN EN 61241-14 : 2005 | Identical |
VDE 0165-2 : 2005 | Identical |
UNE-EN 61241-14:2006 | Identical |
BS EN 61241-14:2004 | Identical |
CEI EN 61241-14 : 2011 | Identical |
UNI EN 13237 : 2012 | POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
BS EN 61241-17:2005 | Electrical apparatus for use in the presence of combustible dust Inspection and maintenance of electrical installations in hazardous areas (other than mines) |
BS EN 61241-0:2006 | Electrical apparatus for use in the presence of combustible dust General requirements |
11/30239006 DC : 0 | BS EN 13237 - POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
BS EN 14677:2008 | Safety of machinery. Secondary steelmaking. Machinery and equipment for treatment of liquid steel |
UNE-EN 1127-1:2012 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
EN 1010-1:2004+A1:2010 | Safety of machinery - Safety requirements for the design and construction of printing and paper converting machines - Part 1: Common requirements |
EN 13237:2012 | Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
EN 61241-17:2005 | Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines) |
EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
I.S. EN 1127-1:2011 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
NF EN 1127-1 : 2011 | EXPLOSIVES ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
DIN EN 1010-1:2011-06 | Safety of machinery - Safety requirements for the design and construction of printing and paper converting machines - Part 1: Common requirements (includes Amendment A1:2010) |
I.S. EN 13237:2012 | POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
DIN EN 1127-1:2011-10 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
I.S. EN 1010-1:2005 | SAFETY OF MACHINERY - SAFETY REQUIREMENTS FOR THE DESIGN AND CONSTRUCTION OF PRINTING AND PAPER CONVERTING MACHINES - PART 1: COMMON REQUIREMENTS |
07/30152812 DC : DRAFT AUG 2007 | BS EN 50174-2 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
I.S. EN 61241-17:2005 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES) |
BS EN 1127-1:2019 | Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology |
BS EN 1010-1 : 2004 | SAFETY OF MACHINERY - SAFETY REQUIREMENTS FOR THE DESIGN AND CONSTRUCTION OF PRINTING AND PAPER CONVERTING MACHINES - PART 1: COMMON REQUIREMENTS |
UNI EN 14677 : 2008 | SAFETY OF MACHINERY - SECONDARY STEELMAKING - MACHINERY AND EQUIPMENT FOR TREATMENT OF LIQUID STEEL |
UNI EN 1010-1 : 2011 | SAFETY OF MACHINERY - SAFETY REQUIREMENTS FOR THE DESIGN AND CONSTRUCTION OF PRINTING AND PAPER CONVERTING MACHINES - PART 1: COMMON REQUIREMENTS |
UNI EN 1127-1 : 2011 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
I.S. EN 50174-2:2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
I.S. EN 61241-0:2006 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 0: GENERAL REQUIREMENTS |
BS EN 13237:2012 | Potentially explosive atmospheres. Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
EN 61241-0:2006 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
EN 14677:2008 | Safety of machinery - Secondary steelmaking - Machinery and equipment for treatment of liquid steel |
I.S. EN 14677:2008 | SAFETY OF MACHINERY - SECONDARY STEELMAKING - MACHINERY AND EQUIPMENT FOR TREATMENT OF LIQUID STEEL |
BS EN 1127-1:2011 | Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology |
DIN EN 13237:2013-01 | POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
BS EN 50174-2 : 2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
IEC 61024-1-1:1993 | Protection of structures against lightning - Part 1: General principles - Section 1: Guide A: Selection of protection levels for lightning protection systems |
IEC 61024-1:1990 | Protection of structures against lightning - Part 1: General principles |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
ISO 4225:1994 | Air quality General aspects Vocabulary |
IEC 61241-0:2004 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
IEC 61241-11:2005 | Electrical apparatus for use in the presence of combustible dust - Part 11: Protection by intrinsic safety 'iD' |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
IEC 61241-17:2005 | Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines) |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
EN 61241-1:2004/corrigendum Dec. 2006 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1: PROTECTION BY ENCLOSURES "TD" |
IEC 61241-1:2004 | Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD" |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61241-18:2004 | Electrical apparatus for use in the presence of combustible dust - Part 18: Protection by encapsulation 'mD' |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 61241-10:2004 | Electrical apparatus for use in the presence of combustible dust - Part 10: Classification of areas where combustible dusts are or may be present |
IEC 61241-10:2004 | Electrical apparatus for use in the presence of combustible dust - Part 10: Classification of areas where combustible dusts are or may be present |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.