EN 61534-1:2011/A1:2014

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

POWERTRACK SYSTEMS - PART 1: GENERAL REQUIREMENTS (IEC 61534-1:2011/A1:2014)

Superseded date

14-07-2021

Superseded by

EN 61534-1:2011/A2:2021

Published date

12-01-2013

Sorry this product is not available in your region.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Ratings
7 Classification
8 Marking and documentation
9 Construction
10 Clearances, creepage distances and solid insulation
11 Protection against electric shock
12 Terminals and terminations
13 Screws, current carrying parts and connections
14 Mechanical strength
15 Insulation resistance test and dielectric strength test
16 Normal operation
17 Temperature rise
18 Short-circuit protection and short-circuit withstand
   strength
19 Resistance to heat
20 Fire hazard
21 External influences
22 Electromagnetic compatibility
Annex A (normative) - Measurement of clearances and
        creepage distances
Annex B (normative) - Proof tracking test
Annex C (normative) - Relationship between rated impulse
        withstand voltage, rated voltage and overvoltage
        category III
Annex D (normative) - Pollution degree
Annex E (informative) - Diagram for the dimensioning of
        clearances and creepage distances
Annex F (normative) - Impulse voltage test
Annex G (normative) - Routine test
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Describes general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz or 60 Hz with a rated current not exceeding 63 A.

Committee
SR 23A
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

BS EN 61534-21:2014 Powertrack systems Particular requirements for powertrack systems intended for wall and ceiling mounting
HD 60364-5-54:2011/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
BS EN 61534-22:2014 Powertrack systems Particular requirements for powertrack systems intended for onfloor or underfloor installation
I.S. EN 61534-22:2014 POWERTRACK SYSTEMS - PART 22: PARTICULAR REQUIREMENTS FOR POWERTRACK SYSTEMS INTENDED FOR ONFLOOR OR UNDERFLOOR INSTALLATION
I.S. EN 61534-21:2014 POWERTRACK SYSTEMS - PART 21: PARTICULAR REQUIREMENTS FOR POWERTRACK SYSTEMS INTENDED FOR WALL AND CEILING MOUNTING
HD 62640:2015/A11:2016 RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES (IEC 62640:2011, MODIFIED)
CEI EN 61534-21 : 2015 POWERTRACK SYSTEMS - PART 21: PARTICULAR REQUIREMENTS FOR POWERTRACK SYSTEMS INTENDED FOR WALL AND CEILING MOUNTING
S.R. HD 60364-5-54:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
EN 61534-21:2014 Powertrack systems - Part 21: Particular requirements for powertrack systems intended for wall and ceiling mounting
EN 61534-22:2014 Powertrack systems - Part 22: Particular requirements for powertrack systems intended for onfloor or underfloor installation
UNE-HD 62640:2016 Residual current devices with or without overcurrent protection for socket-outlets for household and similar uses
PRHD 62640 : DRAFT 2014 RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES (IEC 62640:2011, MODIFIED)
I.S. HD 60364-5-54:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
I.S. HD 62640:2015 RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES
UNE-HD 60364-5-54:2015 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
EN 60999-2:2003 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm² up to 300 mm² (included)
IEC 60038:2009 IEC standard voltages
EN 60998-1:2004 Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements
IEC 60998-1:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60050-195:1998 International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock
IEC 60998-2-3:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units
PREN 60038 : DRAFT 2011 CENELEC STANDARD VOLTAGES
EN 60695-10-2:2014 Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV Plugs and socket-outlets for household and similar purposes - Part1: General requirements
EN 60127-1:2006/A2:2015 MINIATURE FUSES - PART 1: DEFINITIONS FOR MINIATURE FUSES AND GENERAL REQUIREMENTS FOR MINIATURE FUSE-LINKS
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60439-2:2000+AMD1:2005 CSV Low-voltage switchgear and controlgear assemblies - Part 2: Particular requirements for busbar trunking systems (busways)
IEC 60999-2:2003 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included)
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 61210:2010 Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
IEC 60570:2003+AMD1:2017 CSV Electrical supply track systems for luminaires
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links
IEC 60695-11-2:2017 Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance
EN ISO 1456:2009 Metallic and other inorganic coatings - Electrodeposited coatings of nickel, nickel plus chromium, copper plus nickel and of copper plus nickel plus chromium (ISO 1456:2009)
ISO 2081:2008 Metallic and other inorganic coatings Electroplated coatings of zinc with supplementary treatments on iron or steel
EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
IEC 60999-1:1999 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
HD 60364-4-444:2010/AC:2012 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES
ISO 1456:2009 Metallic and other inorganic coatings — Electrodeposited coatings of nickel, nickel plus chromium, copper plus nickel and of copper plus nickel plus chromium
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
ISO 2093:1986 Electroplated coatings of tin — Specification and test methods
EN 61032:1998 Protection of persons and equipment by enclosures - Probes for verification
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 61210:2010 Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 60999-1:2000 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included)
IEC 60695-10-2:2014 Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 61032:1997 Protection of persons and equipment by enclosures - Probes for verification
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
EN 60439-2:2000/A1:2005 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 2: PARTICULAR REQUIREMENTS FOR BUSBAR TRUNKING SYSTEMS (BUSWAYS)
EN 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014)
EN 60695-11-2:2017 Fire hazard testing - Part 11-2: Test flames - 1 kW nominal pre-mixed flame - Apparatus, confirmatory test arrangement and guidance
EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.