• EN 61881-1:2011

    Current The latest, up-to-date edition.

    Railway applications - Rolling stock equipment - Capacitors for power electronics - Part 1: Paper/plastic film capacitors

    Available format(s): 

    Language(s): 

    Published date:  04-02-2011

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Service conditions
    5 Quality requirements and tests
    6 Overloads
    7 Safety requirements
    8 Marking
    9 Guide to installation and operation
    Annex A (informative) - Waveforms
    Annex B (normative) - Operational limits of
            capacitors with sinusoidal voltages as
            a function of frequency and at maximum
            temperature (theta[max])
    Annex C (normative) - Resonance frequency measuring
            methods - Examples
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    IEC 61881-1:2010 applies to capacitors for power electronics intended to be used on rolling stock. The rated voltage of capacitors is limited to 10 000 V. The operating frequency of the systems in which these capacitors are used is usually up to 15 kHz, while the pulse frequencies may be up to 5 to 10 times the operating frequency. Distinguishes between AC and DC capacitors.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 9X
    Development Note Supersedes EN 61881. (02/2011)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61287-1:2014 Railway applications - Power converters installed on board rolling stock - Part 1: Characteristics and test methods
    IEC 60931-2:1995 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1000 V - Part 2: Ageing test and destruction test
    IEC 61373:2010 Railway applications - Rolling stock equipment - Shock and vibration tests
    IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
    IEC 62491:2008 Industrial systems, installations and equipment and industrial products - Labelling of cables and cores
    IEC 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
    EN 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
    IEC 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
    EN 61373:2010/AC:2017-09 RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010)
    EN 60721-3-5:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 5: Ground vehicle installations
    IEC 60721-3-5:1997 Classification of environmental conditions - Part 3: Classificationof groups of environmental parameters and their severities -Section 5: Ground vehicle installations
    IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
    IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
    IEC 60077-2:2017 Railway applications - Electric equipment for rolling stock - Part 2: Electrotechnical components - General rules
    IEC 60831-2:2014 Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 2: Ageing test, self-healing test and destruction test
    IEC 60146-1-1:2009 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
    IEC 60871-1:2014 Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General
    EN 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
    IEC 61071:2017 Capacitors for power electronics
    IEC TS 60110-2:2000 Power capacitors for induction heating installations - Part 2: Ageing test, destruction test and requirements for disconnecting internal fuses
    IEC 60831-1:2014 RLV Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation
    EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
    IEC 60050-436:1990 International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors
    IEC 62497-1:2010+AMD1:2013 CSV Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment
    EN 62491:2008 Industrial systems, installations and equipment and industrial products - Labelling of cables and cores
    EN 60695-11-5:2017 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
    IEC 60077-1:2017 Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general rules
    IEC 60695-11-5 : 2.0 FIRE HAZARD TESTING - PART 11-5: TEST FLAMES - NEEDLE-FLAME TEST METHOD - APPARATUS, CONFIRMATORY TEST ARRANGEMENT AND GUIDANCE
    IEC 60695-11-5:2016 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
    IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    IEC TS 60871-2:2014 Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 2: Endurance testing
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    EN 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    IEC 60110-1:1998 Power capacitors for induction heating installations - Part 1: General
    IEC 62498-1:2010 Railway applications - Environmental conditions for equipment - Part 1: Equipment on board rolling stock
    EN 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014)
    EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective