EN 62232:2017
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure
01-12-2017
27-09-2020
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Quick start guide and how to use this document
6 Evaluation processes for product compliance,
product installation compliance and in-situ RF
exposure assessments
7 Determining the evaluation method
8 Evaluation methods
9 Uncertainty
10 Reporting
Annex A (informative) - Source environment plane and
guidance on the evaluation method selection
Annex B (normative) - Evaluation methods
Annex C (informative) - Rationale supporting simplified
product installation criteria
Annex D (informative) - Guidance on comparing evaluated
parameters with a limit value
Annex E (informative) - Uncertainty
Annex F (informative) - Technology-specific guidance
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 62232:2017(E) provides methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure. This document:- considers intentionally radiating RBS which transmit on one or more antennas using one or more frequencies in the range 110 MHz to 100 GHz;- considers the impact of ambient sources on RF exposure at least in the 100 kHz to 300 GHz frequency range;- specifies the methods to be used for RF exposure evaluation for compliance assessment applications, namely: - product compliance - determination of compliance boundary information for an RBS product before it is placed on the market; - product installation compliance - determination of the total RF exposure levels in accessible areas from an RBS product and other relevant sources before the product is put into service; - in-situ RF exposure assessment – measurement of in-situ RF exposure levels in the vicinity of an RBS installation after the product has been taken into operation;- describes several RF field strength and SAR measurement and computation methodologies with guidance on their applicability to address both the in-situ evaluation of installed RBS and laboratory-based evaluations;- describes how surveyors, with a sufficient level of expertise, establish their specific evaluation procedures appropriate for their evaluation purpose;- provides guidance on how to report, interpret and compare results from different evaluation methodologies and, where the evaluation purpose requires it, determine a justified decision against a limit value and- provides short descriptions of the informative example case studies given in the companion Technical Report IEC TR 62669 [1]This second edition cancels and replaces the first edition published in 2011 and constitutes a technical revision.
| Committee |
CLC/TC 106X
|
| DevelopmentNote |
Supersedes EN 50383, EN 50400 and EN 50492. (12/2017)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Withdrawn
|
| Supersedes |
| Standards | Relationship |
| IEC 62232:2017 | Identical |
| CEI EN 62232 : 1ED 2018 | Identical |
| VDE 0848-232:2019-08 | Identical |
| I.S. EN 62232:2017 | Equivalent |
| BS EN 62232:2017 | Equivalent |
| UNE-EN 62232:2017 | Identical |
| BS EN 62232:2017 | Identical |
| ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
| IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
| IEC 62209-2:2010 | Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) |
| EN 62311:2008 | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) |
| CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
| IEC 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
| IEC 62479:2010 | Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
| IEEE C95.3-2002 | IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHz |
| IEC TR 62630:2010 | Guidance for evaluating exposure from multiple electromagnetic sources |
| IEEE C95.1-2005 | IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz |
| IEC 62311:2007 | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) |
| EN 62479:2010 | Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
| EN 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
| IEEE 145-2013 REDLINE | IEEE Standard for Definitions of Terms for Antennas |
| IEC 60050-121:1998 | International Electrotechnical Vocabulary (IEV) - Part 121: Electromagnetism |
| EN 62209-2:2010 | Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) |
| IEC 60050-705:1995 | International Electrotechnical Vocabulary (IEV) - Part 705: Radio wave propagation |
| IEC 60050-712:1992 | International Electrotechnical Vocabulary (IEV) - Part 712: Antennas |
| IEC TR 62669:2011 | Case studies supporting IEC 62232 - Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.