EN 62423:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses
08-05-2021
14-12-2012
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Characteristics
6 Marking and other product information
7 Standard conditions for operation in service and for
installation
8 Conditions for construction and operation
9 Tests
Annex A (normative) - Number of samples to be
submitted and test sequences to be applied for
verification of conformity for type F RCCBs
Annex B (normative) - Number of samples to be
submitted and test sequences to be applied for
verification of conformity for Type F RCBOs
Annex C (normative) - Number of samples to be
submitted and test sequences to be applied for
verification of conformity for Type B RCCBs
Annex D (normative) - Number of samples to be
submitted and test sequences to be applied for
verification of conformity for Type B RCBOs
Annex E (normative) - Routine tests for Type F and
Type B RCDs
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZB (normative) - Special national conditions
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. IEC 62423:2009 specifies requirements and tests for Type F and Type B RCDs (Residual Current Devices). Requirements and tests given in this standard are in addition to the requirements of Type A residual current devices. This standard can only be used together with IEC 61008-1 and IEC 61009-1. Type F RCCBs (Residual Current Circuit Breaker) and Type F RCBOs (Residual current Circuit Breaker with Overcurrent protection) with rated frequency 50 Hz or 60 Hz are intended for installations when frequency inverters are supplied between phase and neutral or phase and earthed middle conductor and are able to provide protection in case of alternating residual sinusoidal at the rated frequency, pulsating direct residual currents and composite residual currents that may occur. Type B RCCBs and Type B RCBOs are able to provide protection in case of alternating residual sinusoidal currents up to 1 000 Hz, pulsating direct residual currents and smooth direct residual currents. This second edition cancels and replaces the first edition published in 2007 and constitutes a technical revision. The main changes from the first edition are as follows: - requirements and tests for Type F RCD have been introduced; - requirements and test for two-pole Type B RCD have been introduced; - new additional requirements and tests for Type B RCDs have been introduced to cover requirements for Type F too.
Committee |
CLC/TC 23E
|
DevelopmentNote |
Supersedes PREN 62423. (12/2012) To be read in conjunction with EN 61008-1 and EN 61009-1. (04/2013)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
OVE/ONORM EN 62423 : 2013 | Identical |
DIN EN 62423:2022-03 | Identical |
CEI EN 62423 : 2013 | Identical |
NF EN 62423 : 2013 | Identical |
NEN EN IEC 62423 : 2013 | Identical |
I.S. EN 62423:2012 | Identical |
DIN EN 62423 : 2013 | Identical |
BS EN 62423:2012 | Identical |
PN EN 62423 : 2013 | Identical |
VDE 0664-40 : 2013 | Identical |
NBN EN 62423 : 2013 | Identical |
UNE-EN 62423:2013 | Identical |
SN EN 62423 : 2012 | Identical |
UNE-HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
UNE-HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
BS EN 62477-1 : 2012 | SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL (IEC 62477-1:2012) |
EN 62606:2013/A1:2017 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES (IEC 62606:2013/A1:2017) |
S.R. HD 60364-5-537:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING |
I.S. EN 62606:2013 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
S.R. HD 60364-7-712:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-712: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - PHOTOVOLTAIC (PV) SYSTEMS |
I.S. HD 50573-5-57:2014 | CO-ORDINATION OF ELECTRICAL EQUIPMENT FOR PROTECTION, ISOLATION, SWITCHING AND CONTROL |
S.R. HD 60364-7-722:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-722: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SUPPLIES FOR ELECTRIC VEHICLES |
UNE-HD 60364-7-712:2017 | Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems |
UNE-HD 60364-5-53:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Switchgear and controlgear |
CEI EN 62606 : 2014 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
S.R. HD 60364-5-53:2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
HD 60364-5-537:2016/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING |
BS EN 62606:2013 | General requirements for arc fault detection devices |
HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
UNE-EN 62752:2017 | In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD) |
EN 62477-1:2012/A1:2017 | SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL (IEC 62477-1:2012/A1:2016) |
HD 60364-5-53:2015/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
HD 60364-7-712:2016 | Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems |
UNE-HD 60364-5-537:2017 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection, isolation, switching, control and monitoring - Clause 537: Isolation and switching |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
EN 61543:1995/A2:2006 | RESIDUAL CURRENT-OPERATED PROTECTIVE DEVICES (RCDS) FOR HOUSEHOLD AND SIMILAR USE - ELECTROMAGNETIC COMPATIBILITY |
IEC 61009-2-1:1991 | Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage |
IEC 61543:1995 | Residual current-operated protective devices (RCDs) for household and similar use - Electromagnetic compatibility |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
IEC 61009-2-2:1991 | Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-2: Applicability of the general rules to RCBO's functionally dependent on line voltage |
IEC 61008-2-2:1990 | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's). Part 2-2: Applicability of the general rules to RCCB's functionally dependent on line voltage |
IEC 61008-2-1:1990 | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's). Part 2-1: Applicability of the general rules to RCCB's functionally independent of line voltage |
IEC TS 60479-2:2007 | Effects of current on human beings and livestock - Part 2: Special aspects |
EN 55014-1:2017 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.