EN ISO 16283-2:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Acoustics - Field measurement of sound insulation in buildings and of building elements - Part 2: Impact sound insulation (ISO 16283-2:2015)
12-07-2019
09-12-2015
European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Instrumentation
5 Frequency range
6 General
7 Default procedure for sound pressure level
measurement
8 Low-frequency procedure for sound pressure level
measurement for the tapping machine as impact source
9 Background noise (default and low-frequency procedure)
10 Reverberation time in the receiving room (default
and low-frequency procedure)
11 Conversion to octave bands
12 Expression of results
13 Uncertainty
14 Test report
Annex A (normative) - Impact sources
Annex B (normative) - Requirements for loudspeakers
used for reverberation time measurements
Annex C (informative) - Forms for the expression of results
Annex D (informative) - Additional guidance
Annex E (informative) - Horizontal measurements - Examples
of suitable impact source and microphone positions
Annex F (informative) - Vertical measurements - Examples
of suitable impact source and microphone positions
Bibliography
ISO 16283-2:20015 specifies procedures to determine the impact sound insulation using sound pressure measurements with an impact source operating on a floor or stairs in a building. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess and compare the impact sound insulation in unfurnished or furnished rooms where the sound field might, or might not approximate to a diffuse field.Two impact sources are described: the tapping machine and the rubber ball. These impact sources do not exactly replicate all possible types of real impacts on floors or stairs in buildings.The tapping machine can be used to assess a variety of light, hard impacts such as footsteps from walkers wearing hard-heeled footwear or dropped objects. A single number quantity can be calculated using the rating procedures in ISO 717‑2. This single number quantity links the measured impact sound insulation using the tapping machine to subjective assessment of general impacts in dwellings that occur on floors or stairs in a building. The tapping machine is also well-suited to the prediction of impact sound insulation using ISO 15712‑2. These two aspects facilitate the specification of impact sound insulation in national building requirements using only measurements with the tapping machine as an impact source.The rubber ball can be used to assess heavy, soft impacts such as from walkers in bare feet or children jumping, as well as quantifying absolute values that can be related to human disturbance in terms of a Fast time-weighted maximum sound pressure level. At present, calculation procedures for a single number quantity do not currently exist in an ISO Standard.
Committee |
CEN/TC 126
|
DevelopmentNote |
Supersedes EN ISO 140-7 & EN ISO 140-14. (01/2016)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
DS EN ISO 16283-2 : 2018 | Identical |
DS EN ISO 16283-2 : 2015 | Identical |
NEN EN ISO 16283-2 : 2015 | Identical |
BS EN ISO 16283-2:2015 | Identical |
NEN-EN-ISO 16283-2:2018 en | Identical |
PN EN ISO 16283-2 : 2016 | Identical |
NF EN ISO 16283-2 : 2016 | Identical |
SN EN ISO 16283-2 : 2015 | Identical |
DIN EN ISO 16283-2:2018-11 | Identical |
UNI EN ISO 16283-2 : 2016 COR 2 2017 | Identical |
SS EN ISO 16283-2 : 2018 | Identical |
UNI EN ISO 16283-2:2018 | Identical |
BS EN ISO 16283-2:2018 | Identical |
ÖNORM EN ISO 16283-2: 2019 01 01 | Identical |
NBN EN ISO 16283-2 : 2016 | Identical |
I.S. EN ISO 16283-2:2018 | Identical |
ISO 16283-2:2015 | Identical |
ONORM EN ISO 16283-2 : 2016 | Identical |
DIN EN ISO 16283-2:2016-05 | Identical |
UNE-EN ISO 16283-2:2016 | Identical |
I.S. EN ISO 16283-2:2015 | Identical |
NS EN ISO 16283-2 : 2015 | Identical |
IEC 61672-2:2013+AMD1:2017 CSV | Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests |
IEC 61183:1994 | Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters |
ISO 717-2:2013 | Acoustics Rating of sound insulation in buildings and of building elements Part 2: Impact sound insulation |
ISO 3382-2:2008 | Acoustics Measurement of room acoustic parameters Part 2: Reverberation time in ordinary rooms |
IEC 60942:2003 | Electroacoustics - Sound calibrators |
OIML R 58 : 1998 | SOUND LEVEL METERS |
OIML R 88 : 1998 | INTEGRATING-AVERAGING SOUND LEVEL METERS |
ISO 18233:2006 | Acoustics Application of new measurement methods in building and room acoustics |
ISO 10140-3:2010 | Acoustics Laboratory measurement of sound insulation of building elements Part 3: Measurement of impact sound insulation |
ISO 10140-5:2010 | Acoustics Laboratory measurement of sound insulation of building elements Part 5: Requirements for test facilities and equipment |
IEC 61672-3:2013 | Electroacoustics - Sound level meters - Part 3: Periodic tests |
IEC 61260:1995 | Electroacoustics - Octave-band and fractional-octave-band filters |
ISO 12999-1:2014 | Acoustics Determination and application of measurement uncertainties in building acoustics Part 1: Sound insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.