HD 632 S1:1998
Current
The latest, up-to-date edition.
POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
26-03-1998
PART 1 Test methods and requirements
PART 2 Additional test methods
PART 3 Test requirements for cables with XLPE insulation and
metallic screen and their accessories
3-D Cables with XLPE insulation and copper screen
and their accessories (Test list 3D)
3-K Cables with XLPE insulation and copper screen
and their accessories (Test list 3K)
3-L Cables with XLPE insulation and metallic screen
and their accessories (Test list 3L)
3-M Cables with XLPE insulation, copper screen and
their accessories (Test list 3M)
3-N Cables with XLPE insulation and copper screen and
their accessories (Test list 3N)
PART 4 Test requirements for cables with XLPE insulation,
metallic screen and metal-laminated sheath and their
accessories
4-A Cables with XLPE insulation and polyolefine compound
sheath (Types 1, 2 and 3)(Test list 4A)
4-C Cables with XLPE insulation, copper or aluminium
wires screen and aluminium or copper laminated
sheath and their accessories (Test list 4C)
4-D Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4D)
4-F Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4F)
4-G Cables with XLPE insulation and metal- laminated
screen and their accessories (Test list 4G)
4-K Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4K)
4-L Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4L)
4-M Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4M)
4-O Cables with XLPE insulation, copper or aluminium
screen and copper or aluminium laminated sheath
and their accessories (Test list 4O)
4-P Cables with XLPE insulation, copper screen and
metal-laminated sheath and their accessories (Test list 4P)
PART 5 Test requirements for cables with XLPE insulation and
metallic sheath and their accessories
5-C Cables with XLPE insulation and lead or lead alloy
sheath, or aluminium or copper sheath and their
accessories (Test list 5C)
5-D Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5D)
5-F Cables with XLPE insulation and lead or lead alloy
sheath and their accessories (Test list 5F)
5-G Cables with XLPE insulation and lead sheath and their
accessories (Test list 5G)
5-H Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5H)
5-K Cables with XLPE insulation and lead sheath and their
accessories (Test list 5K)
5-L Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5L)
5-M Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5M)
5-O Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5O)
5-P Cables with XLPE insulation and lead alloy sheath and
their accessories (Test list 5P)
PART 6 Test requirements for cables with EPR insulation and
metallic screen and their accessories
6-A Cables with HEPR insulation and polyolefine compound
sheath (Types 1, 2 and 3) (Test list 6A)
6-J Cables with HEPR insulation and copper screen and their
accessories (Test list 6J)
6-O Cables with EPR insulation and copper or aluminium screen
and their accessories (Test list 6O)
PART 7 Test requirements for cables with EPR insulation,
metallic screen and metal-laminated sheath and their
accessories
7-O Cables with EPR insulation, copper or aluminium screen
and copper or aluminium-laminated sheath and their
accessories (Test list 7O)
PART 8 Test requirements for cables with EPR insulation and
metallic sheath and their accessories
8-J Cables with HEPR insulation and metallic sheath and
their accessories (Test list 8J)
8-O Cables with EPR insulation and metallic sheath and their
accessories (Test list 8O)
PART 9 (Spare)
PART 10 Test requirements for cables with PE or HDPE insulation,
metallic screen and metal-laminated sheath and their
accessories
10-G Cables with PE or HDPE insulation and metal-laminated
screen and their accessories (Test list 10G)
PART 11 Test requirements for cables with PE or HDPE insulation
and metallic sheath and their accessories
11-G Cables with PE or HDPE insulation and lead sheath
and their accessories (Test list 11G)
Describes test requirements for power cables with extruded insulation, of the types listed in Table 1, and their accessories, of rated voltage, U, above 36 kV (U[m] = 42 kV) up to and including 150 kV (U[m] = 170 kV), for fixed installations intended for transmission and distribution systems, and for use in power generating plants and sub-stations.
Committee |
TC 20
|
DevelopmentNote |
Supersedes UNE HD 632-0 & UNE HD 632-1. (01/2012)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
CEI 20-66 V1 : 2007 | Identical |
NBN HD 632 : 2009 | Identical |
NFC 33 252 : 2002 | Identical |
VDE 0276-632 : 2017 | Identical |
PN HD 632 : 2017 | Identical |
SN HD 632 : 200S1 | Identical |
DIN VDE 0276-632 : 2017 | Identical |
CEI 20-66 : 2010 | Identical |
NEN HD 632 : 2018 | Identical |
UNE-HD 632-0:1999 | Identical |
UNE-HD 632-3A:1999 | Identical |
I.S. HD 632:2016 | Identical |
UNE-HD 632-5A:1999 | Identical |
UNE-HD 632-6A:1999 | Identical |
UNE-HD 632-1:2004 | Identical |
UNE-HD 632-8A:1999 | Identical |
I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
CEI EN 50299-2 : 2016 | OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS |
UNE 211632-4A:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 4A: Cables with XLPE insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath. |
UNE-EN 50299-2:2015 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations |
DIN VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
BS 7970:2012 | Electric cables. Metal foil and longitudinally welded aluminium sheath constructions of power cables having XLPE insulation for rated voltages from 66 kV (U<sub>m</sub> = 72.5 kV) to 132 kV (U<sub>m</sub> = 145 kV) |
BS 7912(2012) : 2012 | POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
12/30244367 DC : 0 | BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
12/30244364 DC : 0 | BS 7970 - ELECTRIC CABLES - METAL FOIL AND LONGITUDINALLY WELDED ALUMINIUM SHEATH CONSTRUCTIONS OF POWER CABLES HAVING XLPE INSULATION FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS EN 50299-2:2014 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Dry-type cable terminations |
CEI EN 50299-1 : 2016 | OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 1: FLUID-FILLED CABLE TERMINATIONS |
BS EN 50299-1:2014 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Fluid-filled cable terminations |
UNE-EN 50299-1:2015 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 1: Fluid-filled cable terminations |
UNE 211632-1:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 1: Requirements and test methods |
I.S. EN 50299-2:2014 | OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
UNE 211632-6A:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 6A: Cables with HEPR insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath. |
13/30281716 DC : 0 | BS EN 50299-2 - OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS |
I.S. EN 50299-1:2014 | OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 1: FLUID-FILLED CABLE TERMINATIONS |
CEI 20-56 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO |
EN 50299-1:2014 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 1: Fluid-filled cable terminations |
EN 50299-2:2014 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations |
UNE-HD 620-1:2010 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 1: General requirements. |