I.S. EN 12405:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
GAS METERS - GAS-VOLUME ELECTRONIC CONVERSION DEVICES
Hardcopy , PDF
15-07-2005
English
01-01-2002
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
1 Scope
2 Normative references
3 Terms, definitions and symbols
3.1 Terms and definitions
3.2 Symbols
4 Principle of measurement
4.1 Conversion as a function of temperature
4.2 Conversion as a function of pressure and
temperature
4.3 Conversion as a function of pressure, temperature
and deviation from the ideal gas law
4.4 Correction of the volume at measurement
conditions
5 Rated operating conditions
5.1 Specified field of measurement
5.1.1 Specified measurement range for gas
pressure
5.1.2 Specified measurement range for gas
temperature
5.1.3 Gas characteristics
5.2 Environmental class
5.2.1 Ambient temperature range
5.2.2 Humidity range
5.3 Power supply
6 Construction requirements
6.1 General
6.2 Casings
6.3 Indications
6.3.1 General
6.3.2 Electronic indicating device
6.4 Inputs for volume conversion
6.5 Battery powered conversion device
6.6 Security devices and alarms
7 Installation requirements
7.1 General
7.2 Temperature transducer
7.3 Pressure transducer
8 Performance
8.1 Reference conditions
8.2 Rated operating condition
8.3 Maximum permissible errors
8.3.1 Error of conversion
8.3.2 Specific errors for a gas-volume conversion
device, type 2
8.4 Influence factors
8.5 Disturbances
8.6 Durability
9 Tests of conformity
9.1 Test conditions
9.2 Tests and their classification
9.3 Sample of gas volume conversion device required
for testing
9.4 Test report
10 Marking
Annex A (normative) Type test
A.1 General conditions
A.2 Accuracy tests under reference conditions
A.3 Effect of ambient temperature
A.4 Effect of damp heat, steady state test
A.5 Effect of damp heat, cyclic test
A.6 Electrical power variation
A.7 Short time power interruption
A.8 Electrical bursts
A.9 Electromagnetic immunity
A.10 Electrostatic discharges
A.11 Effect of an overload of pressure
A.12 Mechanical resistance to overload of pressure
A.13 Effect of vibrations
A.14 Effect of shocks
A.15 Durability
Annex B (informative) Model type test report
B.1 General
B.2 Accuracy tests under reference conditions
B.3 Ambient temperature
B.4 Effect of damp heat, steady state test
B.5 Effect of damp heat, cyclic test
B.6 Electrical power variation
B.7 Short time power interruption
B.8 Electrical bursts
B.9 Electromagnetic immunity
B.10 Electrostatic discharges
B.11 Effect of an overload of static pressure
B.12 Mechanical resistance to overload of pressure
B.13 Effect of vibrations
B.14 Effect of shocks
B.15 Durability
Bibliography
Defines the requirements and tests for the construction, performance, safety and conformity of gas-volume electronic conversion devices associated to gas meters, used to measure volumes of fuel gases of the 1st and 2nd families according to EN 437.
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 12405 : 2002 | Identical |
NF EN 12405 : 2002 | Identical |
NBN EN 12405 : 2002 | Identical |
UNE-EN 12405:2004 | Identical |
SN EN 12405 : 2003 | Identical |
DIN EN 12405:2003-10 | Identical |
NS EN 12405 : 1ED 2002 | Identical |
NEN EN 12405 : 2002 | Identical |
BS EN 12405:2002 | Identical |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
EN 50039:1980 | Electrical apparatus for potentially explosive atmospheres - Intrinsically safe electrical systems 'i' |
ISO 5168:2005 | Measurement of fluid flow — Procedures for the evaluation of uncertainties |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60950:2000/corrigendum:2002 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
EN 24006:1993 | Measurement of fluid flow in closed conduits - Vocabulary and symbols (ISO 4006:1991) |
ISO 12213-3:2006 | Natural gas Calculation of compression factor Part 3: Calculation using physical properties |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 50017:1998 | Electrical apparatus for potentially explosive atmospheres - Powder filling "q" |
EN 50019:2000/corrigendum Apr. 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
EN 50018 : 2000 AMD 1 2002 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D" |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
ISO 2768:1973 | Permissible machining variations in dimensions without tolerance indication |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
EN 437:2003+A1:2009 | Test gases - Test pressures - Appliance categories |
EN 1359:2017 | Gas meters - Diaphragm gas meters |
ISO 12213-1:2006 | Natural gas Calculation of compression factor Part 1: Introduction and guidelines |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 50015:1998 | Electrical apparatus for potentially explosive atmospheres - Oil immersion "o" |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 50016:2002 | Electrical apparatus for potentially explosive atmospheres - Pressurized apparatus "p" |
ISO 12213-2:2006 | Natural gas Calculation of compression factor Part 2: Calculation using molar-composition analysis |
EN 50014:1997/A2:1999 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
EN 1776:2015 | Gas infrastructure - Gas measuring systems - Functional requirements |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.