I.S. EN 60076-16:2011
Current
The latest, up-to-date edition.
POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS (IEC 60076-16:2011)
Hardcopy , PDF
English
01-01-2011
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Electrical characteristics
6 Rating plate
7 Tests
Annex A (informative) - Calculation method and tables
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Pertains to dry-type and liquid-immersed transformers for rated power 100 kVA up to 10000 kVA for wind turbine applications having a winding with highest voltage for equipment up to and including 36 kV and at least one winding operating at a voltage greater than 1,1 kV.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
IEC 60076-16:2011 | Identical |
EN 60076-16:2011 | Identical |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
IEC 62271-202:2014 | High-voltage switchgear and controlgear - Part 202: High-voltage/ low-voltage prefabricated substation |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
EN 60076-13 : 2006 | POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
EN 61100:1992 | Classification of insulating liquids according to fire point and net calorific value |
IEC 61100:1992 | Classification of insulating liquids according to fire-point and net calorific value |
EN 61400-1:2005/A1:2010 | WIND TURBINES - PART 1: DESIGN REQUIREMENTS |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60076-1:2011 | Power transformers - Part 1: General |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
IEC 61378-3:2015 | Converter transformers - Part 3: Application guide |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 60076-13:2006 | Power transformers - Part 13: Self-protected liquid-filled transformers |
EN 61378-1:2011 | Convertor transformers - Part 1: Transformers for industrial applications |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
IEC 61400-1:2005+AMD1:2010 CSV | Wind turbines - Part 1: Design requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.