National Foreword
FOREWORD
0 Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols, abbreviated terms
and conventions
4 Overview
5 General
6 Safety communication layer services
7 Safety communication layer protocol
8 Safety communication layer management
9 System requirements
10 Assessment
11 FSCP 8/1
12 FSCP 8/2
Annex A (informative) - Additional information for
functional safety communication profiles
of CPF 8
Annex B (informative) - Information for assessment
of the functional safety communication
profiles of CPF 8
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines a safety communication layer (services and protocol) based on CPF 8 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 18 and Type 23.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
230
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
IEC 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
IEC 61326-3-2:2017 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment |
IEC 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
ISO/IEC 7498-1:1994 | Information technology — Open Systems Interconnection — Basic Reference Model: The Basic Model |
EN 61158-6-18:2012 | Industrial communication networks - Fieldbus specifications - Part 6-18: Application layer protocol specification - Type 18 elements |
IEC 62280:2014 | Railway applications - Communication, signalling and processing systems - Safety related communication in transmission systems |
IEC 61000-6-7:2014 | Electromagnetic compatibility (EMC) - Part 6-7: Generic standards - Immunity requirements for equipment intended to perform functions in a safety-related system (functional safety) in industrial locations |
EN 61784-3:2016/A1:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3: FUNCTIONAL SAFETY FIELDBUSES - GENERAL RULES AND PROFILE DEFINITIONS (IEC 61784-3:2016/A1:2017) |
IEC TR 62210:2003 | Power system control and associated communications - Data and communication security |
EN 61131-2:2007 | Programmable controllers - Part 2: Equipment requirements and tests |
ISO 10218-1:2011 | Robots and robotic devices Safety requirements for industrial robots Part 1: Robots |
NFPA 79 : 2015 | ELECTRICAL STANDARD FOR INDUSTRIAL MACHINERY |
IEC TS 61000-1-2:2008 | Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena |
IEEE 802.3-2012 | IEEE Standard for Ethernet |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
IEC 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508) |
IEC 61158-5-18:2010 | Industrial communication networks - Fieldbus specifications - Part 5-18: Application layer service definition - Type 18 elements |
EN 61158-3-18:2008 | Industrial communication networks - Fieldbus specifications - Part 3-18: Data-link layer service definition - Type 18 elements |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61131-6:2012 | Programmable controllers - Part 6: Functional safety |
EN 61158-4-18:2012 | Industrial communication networks - Fieldbus specifications - Part 4-18: Data-link layer protocol specification - Type 18 elements |
EN 61158-5-23:2014 | Industrial communication networks - Fieldbus specifications - Part 5-23: Application layer service definition - Type 23 elements |
EN 61158-5-18:2012 | Industrial communication networks - Fieldbus specifications - Part 5-18: Application layer service definition - Type 18 elements |
ISO 12100:2010 | Safety of machinery — General principles for design — Risk assessment and risk reduction |
IEC 61158-3-18:2007 | Industrial communication networks - Fieldbus specifications - Part 3-18: Data-link layer service definition - Type 18 elements |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEC 61918:2013 | Industrial communication networks - Installation of communication networks in industrial premises |
IEC 61158-6-18:2010 | Industrial communication networks - Fieldbus specifications - Part 6-18: Application layer protocol specification - Type 18 elements |
EN 62061:2005/A2:2015 | SAFETY OF MACHINERY - FUNCTIONAL SAFETY OF SAFETY-RELATED ELECTRICAL, ELECTRONIC AND PROGRAMMABLE ELECTRONIC CONTROL SYSTEMS (IEC 62061:2005/A2:2015) |
IEC TR 62685:2010 | Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs) |
ISO 13849-2:2012 | Safety of machinery — Safety-related parts of control systems — Part 2: Validation |
IEC 61158-4-18:2010 | Industrial communication networks - Fieldbus specifications - Part 4-18: Data-link layer protocol specification - Type 18 elements |
IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
EN 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
ISO/IEC 2382-14:1997 | Information technology Vocabulary Part 14: Reliability, maintainability and availability |
ISO/IEC 2382-16:1996 | Information technology Vocabulary Part 16: Information theory |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
EN 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV | Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems |
EN 61158-6-23:2014 | Industrial communication networks - Fieldbus specifications - Part 6-23: Application layer protocol specification - Type 23 elements |
IEC TR 62059-11:2002 | Electricity metering equipment - Dependability - Part 11: General concepts |
EN 61326-3-1:2017 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - General industrial applications |
ISO 13849-1:2015 | Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design |
EN 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
IEC 61800-5-2:2016 | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
IEC 61326-3-1:2017 | Electrical equipment for measurement, control and laboratory use - EMC requirements – Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) – General industrial applications |
IEC 61784-3:2016+AMD1:2017 CSV | Industrial communication networks - Profiles - Part 3: Functional safety fieldbuses - General rules and profile definitions |
IEC 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |