INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Ratings
4.1 Rated voltages
4.2 Insulation levels
4.3 Rated currents
4.4 Minimum nominal creepage distance
5 Operating conditions
5.1 General
5.2 Factors affecting the design, testing and application
6 General requirements
6.1 List of variables
6.2 Nameplate markings
7 Test requirements
7.1 General requirements
7.2 Test classification
8 Type tests
8.1 Dry power-frequency voltage withstand test with
partial discharge measurement
8.2 Dry lightning impulse voltage withstand test (BIL)
8.3 Dry or wet switching impulse voltage withstand
8.4 Temperature rise test
8.5 Cantilever load withstand test
8.6 Tightness test on liquid-filled, compound-filled
and liquid-insulated bushings
8.7 Internal pressure test on gas-filled, gas-insulated
and gas-impregnated bushings
8.8 Verification of dimensions
9 Routine tests
9.1 Measurement of dielectric dissipation factor
(tan delta) and capacitances
9.2 Dry lightning impulse voltage withstand test (BIL)
9.3 Dry power-frequency voltage withstand test with
partial discharge measurement
9.4 DC applied voltage withstand test with partial
discharge measurement
9.5 Polarity reversal test with partial discharge
measurement
9.6 Test of tap insulation
9.7 Internal pressure test on gas-filled, gas-insulated
and gas-impregnated bushings
9.8 Tightness test on liquid-filled, compound-filled
and liquid-insulted bushings
9.9 Tightness test on gas-filled, gas-insulated and
gas-impregnated bushings
9.10 Tightness test at the flange or other fixing device
9.11 Visual inspection and dimensional check
10 Special tests
10.1 Artificial pollution test
10.2 Even wetting d.c. voltage test
10.3 Uneven wetting d.c. voltage test
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Applicable to outdoor and indoor bushings of any voltage used on d.c. systems, of capacitance graded or gas insulated types for use as components of oil-filled converter transformers and smoothing reactors, as well as air-to-air d.c. bushings.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
63
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
BS EN 62199:2004 | Identical |
EN 62199:2004 | Identical |
IEC 62199:2004 | Identical |
DIN EN 62199 : 2005 | Identical |
NF EN 62199 : 2004 | Identical |
NBN EN 62199 : 2005 | Identical |
UNE-EN 62199:2005 | Identical |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
IEC TS 61462:1998 | Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
EN 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEC TS 61245:2015 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC TS 61463:2016 | Bushings - Seismic qualification |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.