I.S. EN 62271-100:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS
Hardcopy , PDF
23-09-2021
English
01-01-2009
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guidance to the selection of circuit-breakers
for service
9 Information to be given with enquiries, tenders
and orders
10 Rules for transport, storage, installation,
operation and maintenance
11 Safety
12 Influence of the product on the environment
Annex A (normative) - Calculation of transient recovery
voltages for short-line faults from rated
characteristics
Annex B (normative) - Tolerances on test quantities during
type tests
Annex C (normative) - Records and reports of type tests
Annex D (normative) - Determination of short-circuit power
factor
Annex E (normative) - Method of drawing the envelope of the
prospective transient recovery voltage of a circuit
and determining the representative parameters
Annex F (normative) - Methods of determining prospective
transient recovery voltage waves
Annex G (normative) - Rationale behind introduction of
circuit-breakers class E2
Annex H (informative) - Inrush currents of single and
back-to-back capacitor banks
Annex I (informative) - Explanatory notes
Annex J (informative) - Test current and line length
tolerances for short-line fault testing
Annex K (informative) - List of symbols and abbreviations
used in this standard
Annex L (informative) - Explanatory notes on the revision
of TRVs for circuit-breakers of rated voltages higher
than 1 kV and less than 100 kV
Annex M (normative) - Requirements for breaking of
transformer-limited faults by circuit-breakers with
rated voltage higher than 1 kV
Annex N (normative) - Use of mechanical characteristics and
and related requirements
Annex O (informative) - Guidance for short-circuit and switching
test procedures for metal-enclosed and dead tank
circuit-breakers
Annex P (normative) - Calculation of the TRV parameters during
asymmetrical fault condition (T100a)
Annex Q (informative) - Examples for the application of the
asymmetry criteria during asymmetrical test-duty T100a
Annex R (normative) - Requirements for circuit-breakers with
opening resistors
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to a.c. circuit-breakers designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1000 V.
DevelopmentNote |
Supersedes I.S. HD 348 (01/2003) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
1046
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.