I.S. EN IEC 62485-2:2018
Current
The latest, up-to-date edition.
SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 2: STATIONARY BATTERIES
Hardcopy , PDF
English
22-05-2018
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Protection against electric shock
5 Disconnection and separation
6 Prevention of short circuits and protection from
other effects of electric current
7 Provisions against explosion hazards
8 Provision against electrolyte hazard
9 Accommodation, housing
10 Charge current requirements
11 Identification labels, warning notices and instructions
for use, installation and maintenance
12 Transportation, storage, disposal and environmental
aspects
13 Inspection and monitoring
Annex A (informative) - Charging methods and modes of
operation
Annex B (informative) - Calculation of safety distance d to
protect against explosion hazards
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Pertains to stationary secondary batteries and battery installations with a maximum voltage of DC 1500 V (nominal) and describes the principal measures for protections against hazards generated from: - electricity, - gas emission, - electrolyte.
Committee |
TC 21
|
DevelopmentNote |
Supersedes I.S. EN 50272-2. For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (06/2018)
|
DocumentType |
Standard
|
ISBN |
978-2-88910-996-8
|
Pages |
90
|
ProductNote |
The date of any NSAI previous adoption may not match the date of its original CEN/CENELEC document.
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 62485-2:2010 | Identical |
EN IEC 62485-2:2018 | Identical |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 62259:2003 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination |
HD 60364-4-43:2010 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 60896-11:2002 | Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
IEC TR 61438:1996 | Possible safety and health hazards in the use of alkaline secondary cells and batteries - Guide to equipment manufacturers and users |
IEC TS 61201:2007 | Use of conventional touch voltage limits - Application guide |
EN 61660-2:1997 | Short-circuit currents in d.c. auxiliary installations in power plants and substations - Part 2: Calculation of effects |
IEC 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
IEC 61660-2:1997 | Short-circuit currents in d.c. auxiliary installations in power plants and substations - Part 2: Calculation of effects |
EN 62259:2004 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination |
IEC 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
IEC 60050-482:2004 | International Electrotechnical Vocabulary (IEV) - Part 482: Primary and secondary cells and batteries |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC TR 62060:2001 | Secondary cells and batteries - Monitoring of lead acid stationary batteries - User guide |
EN 61660-1:1997 | Short-circuit currents in d.c. auxiliary installations in power plants and substations - Part 1: Calculation of short-circuit currents |
IEC TR 60755:2008 | General requirements for residual current operated protective devices |
IEC 61340-4-1:2003+AMD1:2015 CSV | Electrostatics - Part 4-1: Standard test methods for specific applications - Electrical resistance of floor coverings and installed floors |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61660-1:1997 | Short-circuit currents in d.c. auxiliary installations in power plants and substations - Part 1: Calculation of short-circuit currents |
IEC 60896-22:2004 | Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements |
EN 60896-11:2003 | Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60900:2012 | Live working - Hand tools for use up to 1 000 V a.c. and 1 500 V d.c. |
EN 61340-4-1:2004/A1:2015 | ELECTROSTATICS - PART 4-1: STANDARD TEST METHODS FOR SPECIFIC APPLICATIONS - ELECTRICAL RESISTANCE OF FLOOR COVERINGS AND INSTALLED FLOORS (IEC 61340-4-1:2003/A1:2015) |
IEC 60364-7-706:2005 | Low-voltage electrical installations - Part 7-706: Requirements for special installations or locations - Conducting locations with restricted movement |
EN 60900:2012 | LIVE WORKING - HAND TOOLS FOR USE UP TO 1000 V A.C. AND 1500 V D.C. (IEC 60900:2012) |
EN 60622:2003 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60896-22:2004 | Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
IEC 60622:2002 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.