I.S. EN ISO 11135:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
STERILIZATION OF HEALTH-CARE PRODUCTS - ETHYLENE OXIDE - REQUIREMENTS FOR THE DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES (ISO 11135:2014)
Hardcopy , PDF
17-12-2019
English
01-01-2014
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Quality management systems
5 Sterilizing agent characterization
6 Process and equipment characterization
7 Product definition
8 Process definition
9 Validation
10 Routine monitoring and control
11 Product release from sterilization
12 Maintaining process effectiveness
Annex A (normative) - Determination of lethal
rate of the sterilization process - Biological
indicator/bioburden approach
Annex B (normative) - Conservative determination
of lethal rate of the sterilization process -
Overkill approach
Annex C (informative) - Temperature sensors, RH
sensors and biological indicator numbers
Annex D (informative) - Guidance on the application
of the normative requirements
Annex E (normative) - Single Lot Release
Bibliography
Annex ZA (informative) - Relationship between this
European Standard and the Essential
Requirements of EU Directive 90/385/EEC
Annex ZB (informative) - Relationship between this
European Standard and the Essential
Requirements of Directive 93/42/EEC
Defines requirements for the development, validation and routine control of an ethylene oxide sterilization process for medical devices in both the industrial and health care facility settings, and it acknowledges the similarities and differences between the two applications.
DevelopmentNote |
Supersedes SR CEN ISO/TS 11135-2 and I.S. EN ISO 11135-1. (08/2014)
|
DocumentType |
Standard
|
Pages |
100
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN ISO 11135:2014 | Identical |
ISO 11135:2014 | Identical |
IEC 61010-2-040:2015 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
AS/NZS 4187:2014 | Reprocessing of reusable medical devices in health service organisations |
AAMI ST41 : 2008 | ETHYLENE OXIDE STERILIZATION IN HEALTH CARE FACILITIES: SAFETY AND EFFECTIVENESS |
ISO 11607-2:2006 | Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes |
ISO 11737-2:2009 | Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process |
ISO 11737-1:2006 | Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO/TS 16775:2014 | Packaging for terminally sterilized medical devices Guidance on the application of ISO 11607-1 and ISO 11607-2 |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
ISO 22442-1:2015 | Medical devices utilizing animal tissues and their derivatives Part 1: Application of risk management |
AAMI TIR28 : 2016 | PRODUCT ADOPTION AND PROCESS EQUIVALENCE FOR ETHYLENE OXIDE STERILIZATION |
ISO 11138-2:2017 | Sterilization of health care products — Biological indicators — Part 2: Biological indicators for ethylene oxide sterilization processes |
AAMI TIR15 : 2016 | PHYSICAL ASPECTS OF ETHYLENE OXIDE STERILIZATION |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
ISO 11140-1:2014 | Sterilization of health care products Chemical indicators Part 1: General requirements |
ISO/TS 11139:2006 | Sterilization of health care products Vocabulary |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 22442-2:2015 | Medical devices utilizing animal tissues and their derivatives Part 2: Controls on sourcing, collection and handling |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
ISO 11138-1:2017 | Sterilization of health care products — Biological indicators — Part 1: General requirements |
ISO 22442-3:2007 | Medical devices utilizing animal tissues and their derivatives — Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
ISO/IEC 90003:2014 | Software engineering Guidelines for the application of ISO 9001:2008 to computer software |
ISO 14161:2009 | Sterilization of health care products Biological indicators Guidance for the selection, use and interpretation of results |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
ISO 14040:2006 | Environmental management Life cycle assessment Principles and framework |
ISO 17664:2017 | Processing of health care products Information to be provided by the medical device manufacturer for the processing of medical devices |
1994/9/EC : 1994 | DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.