I.S. EN ISO 16061:2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
INSTRUMENTATION FOR USE IN ASSOCIATION WITH NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS (ISO 16061:2015)
Hardcopy , PDF
30-09-2021
English
01-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Intended performance
5 Design attributes
6 Selection of materials
7 Design evaluation
8 Manufacture
9 Sterilization
10 Packaging
11 Information supplied by the manufacturer
Annex A (informative) - Examples of typical
instrument applications, together with
materials found acceptable for instrument
manufacture
Bibliography
Annex ZA (informative) - Relationship between
this European Standard and the Essential
Requirements of EU Directive 93/42/EEC on
medical devices
Defines general requirements for instruments to be used in association with non-active surgical implants.
DevelopmentNote |
Supersedes I.S. EN 12011. (02/2009)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ISO 16061:2015 | Identical |
EN ISO 16061:2015 | Identical |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 15883-1:2006 | Washer-disinfectors Part 1: General requirements, terms and definitions and tests |
ISO 5832-1:2016 | Implants for surgery — Metallic materials — Part 1: Wrought stainless steel |
ISO 11607-2:2006 | Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes |
ISO 5832-11:2014 | Implants for surgery — Metallic materials — Part 11: Wrought titanium 6-aluminium 7-niobium alloy |
ISO 11138-3:2017 | Sterilization of health care products — Biological indicators — Part 3: Biological indicators for moist heat sterilization processes |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
ISO 15882:2008 | Sterilization of health care products — Chemical indicators — Guidance for selection, use and interpretation of results |
ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
ISO 10993-13:2010 | Biological evaluation of medical devices — Part 13: Identification and quantification of degradation products from polymeric medical devices |
ISO 5832-6:1997 | Implants for surgery Metallic materials Part 6: Wrought cobalt-nickel-chromium-molybdenum alloy |
ISO 7151:1988 | Surgical instruments — Non-cutting, articulated instruments — General requirements and test methods |
ISO 11737-2:2009 | Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process |
ISO 11737-1:2006 | Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products |
ISO 5832-5:2005 | Implants for surgery Metallic materials Part 5: Wrought cobalt-chromium-tungsten-nickel alloy |
ISO 15883-3:2006 | Washer-disinfectors Part 3: Requirements and tests for washer-disinfectors employing thermal disinfection for human waste containers |
ISO 5832-3:2016 | Implants for surgery Metallic materials Part 3: Wrought titanium 6-aluminium 4-vanadium alloy |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
EN 2318:1992 | Aerospace series - Aluminium alloy AL-P2024-T3511 - Extruded bars and sections 1,2 mm < or = a or D < or = 150 mm |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
EN 2326:1992 | Aerospace series - Aluminium alloy AL-P6082-T6 - Extruded bars and sections a or D < or = 200 mm |
ISO/TR 14969:2004 | Medical devices Quality management systems Guidance on the application of ISO 13485: 2003 |
ISO 4957:1999 | Tool steels |
ISO 11140-3:2007 | Sterilization of health care products — Chemical indicators — Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test |
EN 2127:1992 | Aerospace series - Aluminium alloy AL-P7075-T73511 - Extruded bars and sections a or D < or = 100 mm |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
ISO 5832-8:1997 | Implants for surgery Metallic materials Part 8: Wrought cobalt-nickel-chromium-molybdenum- tungsten-iron alloy |
ISO 11138-2:2017 | Sterilization of health care products — Biological indicators — Part 2: Biological indicators for ethylene oxide sterilization processes |
ISO 10993-14:2001 | Biological evaluation of medical devices — Part 14: Identification and quantification of degradation products from ceramics |
ISO 11140-1:2014 | Sterilization of health care products Chemical indicators Part 1: General requirements |
ISO 5832-4:2014 | Implants for surgery — Metallic materials — Part 4: Cobalt-chromium-molybdenum casting alloy |
ISO 10993-18:2005 | Biological evaluation of medical devices Part 18: Chemical characterization of materials |
ISO/TS 10993-19:2006 | Biological evaluation of medical devices Part 19: Physico-chemical, morphological and topographical characterization of materials |
ISO 18472:2006 | Sterilization of health care products Biological and chemical indicators Test equipment |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
ISO 11140-4:2007 | Sterilization of health care products — Chemical indicators — Part 4: Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration |
ISO 8601:2004 | Data elements and interchange formats Information interchange Representation of dates and times |
ISO 13408-1:2008 | Aseptic processing of health care products — Part 1: General requirements |
ISO 11137-3:2017 | Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ISO 11137-2:2013 | Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 80000-1:2009 | Quantities and units — Part 1: General |
ISO 5832-2:1999 | Implants for surgery Metallic materials Part 2: Unalloyed titanium |
ISO 5832-7:2016 | Implants for surgery — Metallic materials — Part 7: Forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy |
ISO 7740:1985 | Instruments for surgery Scalpels with detachable blades Fitting dimensions |
EN 2100:1992 | Aerospace series - Aluminium alloy AL-P2014A T4511 - Extruded bars and sections a or D < or = 200 mm |
ISO 8319-2:1986 | Orthopaedic instruments — Drive connections — Part 2: Screwdrivers for single slot head screws, screws with cruciate slot and cross-recessed head screws |
ISO 11140-5:2007 | Sterilization of health care products — Chemical indicators — Part 5: Class 2 indicators for Bowie and Dick-type air removal tests |
ISO 14155:2011 | Clinical investigation of medical devices for human subjects Good clinical practice |
ISO 11138-1:2017 | Sterilization of health care products — Biological indicators — Part 1: General requirements |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
EN 2128:1992 | Aerospace series - Aluminium alloy AL-P7075-T7351 - Drawn bars 6 mm < or = a or D < or = 75 mm |
ISO 14161:2009 | Sterilization of health care products Biological indicators Guidance for the selection, use and interpretation of results |
ISO 15223-1:2016 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements |
EN 2384:1992 | Aerospace series - Aluminium alloy AL-P2014A T6511 - Extruded bars and sections a or D < or = 150 mm |
ISO 15883-2:2006 | Washer-disinfectors Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, bowls, dishes, receivers, utensils, glassware, etc. |
ISO 5832-12:2007 | Implants for surgery Metallic materials Part 12: Wrought cobalt-chromium-molybdenum alloy |
ISO 17664:2017 | Processing of health care products Information to be provided by the medical device manufacturer for the processing of medical devices |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
ISO 5832-9:2007 | Implants for surgery Metallic materials Part 9: Wrought high nitrogen stainless steel |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.