I.S. EN ISO 21649:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS
Hardcopy , PDF
02-09-2023
English
01-01-2009
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Requirements
6 Test methods
7 Test report
8 Information supplied by the manufacturer
Annex A (informative) Two-sided tolerance limit factors (k)
Annex B (informative) Examples of accuracy limit calculations
and random settings
Annex C (informative) Correspondence between ISO/IEC
standards and EN standards
Annex ZA (informative) Relationship between this
European Standard and the Essential Requirements
of EU Directive 93/42/EEC on medical devices
Bibliography
Applicable to safety and performance and testing requirements for single-use and multiple-use needle-free injection systems intended for human use in clinics and other medical settings and for personal use by patients.
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ONORM EN ISO 21649 : 2010 | Identical |
UNE-EN ISO 21649:2010 | Identical |
NEN EN ISO 21649 : 2009 | Identical |
SN EN ISO 21649 : 2010 | Identical |
NF EN ISO 21649 : 2009 | Identical |
EN ISO 21649:2009 | Identical |
ISO 21649:2006 | Identical |
NS EN ISO 21649 : 2009 | Identical |
NBN EN ISO 21649 : 2009 | Identical |
BS EN ISO 21649:2009 | Identical |
DIN EN ISO 21649:2010-01 | Identical |
ISO 11202:2010 | Acoustics Noise emitted by machinery and equipment Determination of emission sound pressure levels at a work station and at other specified positions applying approximate environmental corrections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
ISO 14155-2:2003 | Clinical investigation of medical devices for human subjects Part 2: Clinical investigation plans |
ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
ISO/IEC Guide 98:1993 | Guide to the expression of uncertainty in measurement (GUM) |
ISO 14253-1:2017 | Geometrical product specifications (GPS) — Inspection by measurement of workpieces and measuring equipment — Part 1: Decision rules for verifying conformity or nonconformity with specifications |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
IEC 60721-3-7:1995+AMD1:1996 CSV | Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use |
ISO 14155-1:2003 | Clinical investigation of medical devices for human subjects Part 1: General requirements |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
ISO 7886-1:2017 | Sterile hypodermic syringes for single use — Part 1: Syringes for manual use |
ISO 3746:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Survey method using an enveloping measurement surface over a reflecting plane |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
ISO 11134:1994 | Sterilization of health care products — Requirements for validation and routine control — Industrial moist heat sterilization |
ISO 11137:1995 | Sterilization of health care products Requirements for validation and routine control Radiation sterilization |
IEC 60601-1-1:2000 | Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems |
ISO 11201:2010 | Acoustics Noise emitted by machinery and equipment Determination of emission sound pressure levels at a work station and at other specified positions in an essentially free field over a reflecting plane with negligible environmental corrections |
ISO 11204:2010 | Acoustics Noise emitted by machinery and equipment Determination of emission sound pressure levels at a work station and at other specified positions applying accurate environmental corrections |
ISO 15223:2000 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.