I.S. HD 632:2016
Current
The latest, up-to-date edition.
POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
Hardcopy , PDF
English
01-01-2016
PART 1 Test methods and requirements
PART 2 Additional test methods
PART 3 Test requirements for cables with XLPE insulation and
metallic screen and their accessories
3-D Cables with XLPE insulation and copper screen
and their accessories (Test list 3D)
3-K Cables with XLPE insulation and copper screen
and their accessories (Test list 3K)
3-L Cables with XLPE insulation and metallic screen
and their accessories (Test list 3L)
3-M Cables with XLPE insulation, copper screen and
their accessories (Test list 3M)
3-N Cables with XLPE insulation and copper screen and
their accessories (Test list 3N)
PART 4 Test requirements for cables with XLPE insulation,
metallic screen and metal-laminated sheath and their
accessories
4-A Cables with XLPE insulation and polyolefine compound
sheath (Types 1, 2 and 3)(Test list 4A)
4-C Cables with XLPE insulation, copper or aluminium
wires screen and aluminium or copper laminated
sheath and their accessories (Test list 4C)
4-D Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4D)
4-F Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4F)
4-G Cables with XLPE insulation and metal- laminated
screen and their accessories (Test list 4G)
4-K Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4K)
4-L Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4L)
4-M Cables with XLPE insulation, copper screen and
aluminium-laminated sheath and their accessories
(Test list 4M)
4-O Cables with XLPE insulation, copper or aluminium
screen and copper or aluminium laminated sheath
and their accessories (Test list 4O)
4-P Cables with XLPE insulation, copper screen and
metal-laminated sheath and their accessories (Test list 4P)
PART 5 Test requirements for cables with XLPE insulation and
metallic sheath and their accessories
5-C Cables with XLPE insulation and lead or lead alloy
sheath, or aluminium or copper sheath and their
accessories (Test list 5C)
5-D Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5D)
5-F Cables with XLPE insulation and lead or lead alloy
sheath and their accessories (Test list 5F)
5-G Cables with XLPE insulation and lead sheath and their
accessories (Test list 5G)
5-H Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5H)
5-K Cables with XLPE insulation and lead sheath and their
accessories (Test list 5K)
5-L Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5L)
5-M Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5M)
5-O Cables with XLPE insulation and metallic sheath and
their accessories (Test list 5O)
5-P Cables with XLPE insulation and lead alloy sheath and
their accessories (Test list 5P)
PART 6 Test requirements for cables with EPR insulation and
metallic screen and their accessories
6-A Cables with HEPR insulation and polyolefine compound
sheath (Types 1, 2 and 3) (Test list 6A)
6-J Cables with HEPR insulation and copper screen and their
accessories (Test list 6J)
6-O Cables with EPR insulation and copper or aluminium screen
and their accessories (Test list 6O)
PART 7 Test requirements for cables with EPR insulation,
metallic screen and metal-laminated sheath and their
accessories
7-O Cables with EPR insulation, copper or aluminium screen
and copper or aluminium-laminated sheath and their
accessories (Test list 7O)
PART 8 Test requirements for cables with EPR insulation and
metallic sheath and their accessories
8-J Cables with HEPR insulation and metallic sheath and
their accessories (Test list 8J)
8-O Cables with EPR insulation and metallic sheath and their
accessories (Test list 8O)
PART 9 (Spare)
PART 10 Test requirements for cables with PE or HDPE insulation,
metallic screen and metal-laminated sheath and their
accessories
10-G Cables with PE or HDPE insulation and metal-laminated
screen and their accessories (Test list 10G)
PART 11 Test requirements for cables with PE or HDPE insulation
and metallic sheath and their accessories
11-G Cables with PE or HDPE insulation and lead sheath
and their accessories (Test list 11G)
Describes test requirements for power cables with extruded insulation, of the types listed in Table 1, and their accessories, of rated voltage, U, above 36 kV (U[m] = 42 kV) up to and including 150 kV (U[m] = 170 kV), for fixed installations intended for transmission and distribution systems, and for use in power generating plants and sub-stations.
DocumentType |
Standard
|
Pages |
644
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
HD 632 : 1998 | Identical |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
EN 60229:2008 | Electric cables - Tests on extruded oversheaths with a special protective function |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
HD 632 : 1998 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
HD 323.2.11 : 200S1 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST KA: SALT MIST |
IEC 61443:1999+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEC 60228:2004 | Conductors of insulated cables |
EN 50307:2002 | Lead and lead alloys - Lead and lead alloy sheaths and sleeves of electric cables |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
IEC 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
ISO 606:2015 | Short-pitch transmission precision roller and bush chains, attachments and associated chain sprockets |
EN 50266-1:2001 | Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Part 1: Apparatus |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
EN 60507:2014 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
HD 626 S1:1996/A2:2002 | OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 62230:2006+AMD1:2013 CSV | Electric cables - Spark-test method |
IEC 60853-2:1989 | Calculation of the cyclic and emergency current rating of cables. Part 2: Cyclic rating of cables greater than 18/30 (36) kV and emergency ratings for cables of all voltages |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
EN 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
IEC 60229:2007 | Electric cables - Tests on extruded oversheaths with a special protective function |
EN 50062:1991 | Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
EN 60230:2002 | Impulse tests on cables and their accessories |
EN 62230:2007/A1:2014 | ELECTRIC CABLES - SPARK-TEST METHOD |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
ISO 48:2010 | Rubber, vulcanized or thermoplastic Determination of hardness (hardness between 10 IRHD and 100 IRHD) |
HD 329 : 200S1 | TESTS ON HOLLOW INSULATORS FOR USE IN ELECTRICAL EQUIPMENT |
EN 50267-2-2:1998 | Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity |
IEC 60287-1-1:2006+AMD1:2014 CSV | Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General |