IEC 60079-11:2011 RLV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
13-01-2023
English - French
29-07-2011
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Grouping and classification of intrinsically safe
apparatus and associated apparatus
5 Levels of protection and ignition compliance
requirements of electrical apparatus
6 Apparatus construction
7 Components on which intrinsic safety depends
8 Infallible components, infallible assemblies of
components and infallible connections on which
intrinsic safety depends
9 Supplementary requirements for specific apparatus
10 Type verifications and type tests
11 Routine verifications and tests
12 Marking
13 Documentation
Annex A (normative) - Assessment of intrinsically safe
circuits
Annex B (normative) - Spark test apparatus for intrinsically
safe circuits
Annex C (informative) - Measurement of creepage distances,
clearances and separation distances through casting
compound and through solid insulation
Annex D (normative) - Encapsulation
Annex E (informative) - Transient energy test
Annex F (normative) - Alternative separation distances for
assembled printed circuit boards and separation
of components
Annex G (normative) - Fieldbus intrinsically safe concept
(FISCO) - Apparatus requirements
Annex H (informative) - Ignition testing of semiconductor
limiting power supply circuits
Bibliography
IEC 60079-11:2011 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60079-11:2011 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere and for associated apparatus, which is intended for connection to intrinsically safe circuits which enter such atmospheres. This type of protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing an explosion in the surrounding explosive atmospheres. This standard is also applicable to electrical equipment or parts of electrical equipment located outside the explosive atmosphere or protected by another Type of Protection listed in IEC 60079-0, where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits exposed to the explosive atmosphere are evaluated for use in such an atmosphere by applying this standard. The requirements for intrinsically safe systems are provided in IEC 60079-25. This standard supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirements of this standard shall take precedence. This sixth edition cancels and replaces the fifth edition of IEC 60079-11 published in 2006, the first edition of IEC 61241-11 published in 2005, and partially replaces the second edition of IEC 60079-27 published in 2008 and constitutes a full technical revision. The significant changes with respect to the previous edition are listed below:
- Inclusion of non-edition specific references to IEC 60079-0.
- The merging of the apparatus requirements for FISCO from IEC 60079-27.
- The merging of the requirements for combustible dust atmospheres from IEC 61241-11.
- Clarification of the requirements for accessories connected to intrinsically safe apparatus; such as chargers and data loggers.
- Addition of new test requirements for opto-isolators.
- Introduction of Annex H about ignition testing of semiconductor limiting power supply circuits.
The contents of the corrigendum 1 (January 2012), the interpretation sheets 1 (October 2014), 2 (July 2016), 3 (July 2016), 4 (April 2019), 5 (August 2019), 6 (December 2019) and 7 (May 2024) have been included in this copy.
Committee |
TC 31/SC 31G
|
DevelopmentNote |
Stability date: 2018. (09/2017)
|
DocumentType |
Redline
|
Pages |
437
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
IEC 60317-3:2004+AMD1:2010 CSV | Specifications for particular types of winding wires - Part 3: Polyester enamelled round copper wire, class 155 |
IEC 60317-7:1990+AMD1:1997+AMD2:1997 CSV | Specifications for particular types of winding wires - Part 7: Polyimide enamelled round copper wire, class 220 |
IPC 2152 : 0 | STANDARD FOR DETERMINING CURRENT CARRYING CAPACITY IN PRINTED BOARD DESIGN |
IEC 60317-8:2010 | Specifications for particular types of winding wires - Part 8: Polyesterimide enamelled round copper wire, class 180 |
IEC 62013-1:2005 | Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60317-13:2010 | Specifications for particular types of winding wires - Part 13: Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, class 200 |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60079-25:2010 | Explosive atmospheres - Part 25: Intrinsically safe electrical systems |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 61086-1:2004 | Coatings for loaded printed wire boards (conformal coatings) - Part 1: Definitions, classification and general requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.