IEC 60143-2:2012 covers protective equipment for series capacitor banks, with a size larger than 10 Mvar per phase. Protective equipment is defined as the main circuit apparatus and ancillary equipment, which are part of a series capacitor installation, but which are external to the capacitor part itself. The recommendations for the capacitor part are given in IEC 60143-1:2004. The protective equipment is mentioned in Clause 3 and 10.6 of IEC 60143-1:2004. This second edition cancels and replaces the first edition published in 1994. It constitutes a technical revision. The main changes with respect to the previous edition are:
- updated with respect to new and revised component standards;
- updates with respect to technology changes. Outdated technologies have been removed, i.e. series capacitors with dual self-triggered gaps. New technologies have been added, i.e. current sensors instead of current transformers;
- the testing of spark gaps has been updated to more clearly specify requirements and testing procedures. A new bypass making current test replaces the old discharge current test;
- Clause 5, Guide, has been expanded with more information about different damping circuits and series capacitor protections. Keywords: protective equipment for series capacitor banks
Committee |
TC 33
|
DevelopmentNote |
Stability Date: 2020. (12/2012)
|
DocumentType |
Standard
|
Pages |
120
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IS 9835 : Part 2 : 2021 | Identical |
SN EN 60143-2:2013 | Identical |
NF EN 60143-2 : 2013 | Identical |
GOST IEC 60143-2 : 2013 | Identical |
NEN EN IEC 60143-2 : 2013 | Identical |
PN EN 60143-2 : 2013 | Identical |
VDE 0560-43 : 2014-01 | Identical |
DIN EN 60143-2 : 2014-01 | Identical |
UNE-EN 60143-2:1998 | Identical |
BS EN 60143-2:2013 | Identical |
CEI EN 60143-2 : 2014 | Identical |
EN 60143-2:2013 | Identical |
PNE-FprEN 60143-2 | Identical |
UNE-EN 60143-2:2013 | Identical |
SN EN 60143-2 : 1994 | Identical |
I.S. EN 60143-2:2013 | Identical |
NEN 10143-2 : 1995 | Identical |
BS EN 60143-4:2010 | Series capacitors for power systems Thyristors controlled series capacitors |
BS EN 60143-3:2015 | Series capacitors for power systems Internal fuses |
I.S. EN 60143-4:2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
NF EN 60143-4 : 2011 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
IEC PAS 62271-109:2002 | High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches |
IEC 60143-1:2015 | Series capacitors for power systems - Part 1: General |
EN 62271-109:2009/A1:2013 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008/A1:2013) |
EN 60831-1:2014/AC:2014 | SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION |
EN 60143-1:2015/AC:2017-05 | Series capacitors for power systems - Part 1: General |
01/203455 DC : DRAFT MAY 2001 | IEC 60143-1 ED.4.0 - SERIES CAPACITORS FOR POWER SYSTEMS |
08/30179134 DC : DRAFT MAR 2008 | BS EN 60143-4 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
CEI EN 60143-4 : 2012 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
14/30310457 DC : 0 | BS EN 60143-1 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 1: GENERAL |
BS EN 62271-100 : 2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008) |
I.S. EN 60831-1:2014-2015-10 | SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION |
IEC 60143-4:2010 | Series capacitors for power systems - Part 4: Thyristor controlled series capacitors |
UNE-EN 62271-100:2011 | High-voltage switchgear and controlgear -- Part 100: Alternating-current circuit-breakers |
14/30300750 DC : 0 | BS EN 60143-3 ED 2.0 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 3: INTERNAL FUSES |
BS EN 60099-9:2014 | Surge arresters Metal-oxide surge arresters without gaps for HVDC converter stations |
BIS IS/IEC 62271-109 : 2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES |
EN 62271-100 : 2009 AMD 2/COR 18 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008/A2:2017/COR1:2018) |
IEC TR 62271-306:2012 | High-voltage switchgear and controlgear - Part 306: Guide to IEC 62271-100, IEC 62271-1 and other IEC standards related to alternating current circuit-breakers |
IEC 60831-1:2014 RLV | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation |
IEC 60099-9:2014 | Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations |
IEC 62271-109:2008+AMD1:2013 CSV | High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches |
BS EN 60831-1:2014 | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V General. Performance, testing and rating. Safety requirements. Guide for installation and operation |
BS EN 62271-109 : 2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES |
BS EN 60143-1:2015 | Series capacitors for power systems General |
17/30368308 DC : 0 | BS EN 62271-109 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES |
07/30174621 DC : DRAFT DEC 2007 | BS EN 62271-109 AMD1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING CURRENT SERIES CAPACITOR BYPASS SWITCHES |
I.S. EN 60143-1:2015 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 1: GENERAL |
I.S. EN 60099-9:2014 | SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS |
CEI EN 60099-9 : 2015 | SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS |
I.S. EN 60143-3:2015 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 3: INTERNAL FUSES |
I.S. EN 62271-100:2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS |
I.S. EN 62271-109:2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008 (EQV)) |
IEC 60143-3:2015 | Series capacitors for power systems - Part 3: Internal fuses |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
EN 60143-3:2015 | Series capacitors for power systems - Part 3: Internal fuses |
EN 60099-9:2014 | Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations |
EN 60143-4 : 2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60654-4:1987 | Operating conditions for industrial-process measurement and control equipment. Part 4: Corrosive and erosive influences |
IEC 60143-1:2015 | Series capacitors for power systems - Part 1: General |
IEC 61869-3:2011 | Instrument transformers - Part 3: Additional requirements for inductive voltage transformers |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 62217:2012 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC TS 60815-2:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems |
IEC 60358-2:2013 | Coupling capacitors and capacitor dividers - Part 2: AC or DC single-phase coupling capacitor connected between line and ground for power line carrier-frequency (PLC) application |
IEC 60383-1:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria |
IEC 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 60794-1-1:2015 | Optical fibre cables - Part 1-1: Generic specification - General |
IEC 60549:2013 | High-voltage fuses for the external protection of shunt capacitors |
IEC 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General |
IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 1: Current transformers |
IEC 60273:1990 | Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
IEC 60358-1:2012 | Coupling capacitors and capacitor dividers - Part 1: General rules |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
IEC 60255-5:2000 | Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
IEC 60255-1:1967 | Electrical relays - Part 1: Instantaneous all-or-nothing relays |
IEC 60255-21-1:1988 | Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section One: Vibration tests (sinusoidal) |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 61869-5:2011 | Instrument transformers - Part 5: Additional requirements for capacitor voltage transformers |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60794-2:2017 | Optical fibre cables - Part 2: Indoor cables - Sectional specification |
IEC 60654-1:1993 | Industrial-process measurement and control equipment - Operating conditions - Part 1: Climatic conditions |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
IEC 62223:2009 | Insulators - Glossary of terms and definitions |
IEC 60143-3:2015 | Series capacitors for power systems - Part 3: Internal fuses |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
IEC 60383-2:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
IEC TS 60815-3:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems |
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV | High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches |
IEC 60654-3:1983 | Operating conditions for industrial-process measurement and control equipment - Part 3: Mechanical influences |
IEC 62271-109:2008+AMD1:2013 CSV | High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.