• Shopping Cart
    There are no items in your cart

IEC 60317-7:1990+AMD1:1997+AMD2:1997 CSV

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Specifications for particular types of winding wires - Part 7: Polyimide enamelled round copper wire, class 220

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

19-01-2009

Language(s)

English - French

Published date

19-12-1997

€41.59
Excluding VAT

Foreword
Introduction
1. Scope
2. Normative references
3. Definitions and general notes on methods of test
4. Dimensions
5. Electrical resistance
6. Elongation
7. Springiness
8. Flexibility and adherence
9. Heat shock
10. Cut-through
11. Resistance to abrasion
12. Resistance to solvents
13. Breakdown voltage
14. Continuity of insulation
15. Temperature index
16. Resistance to refrigerants
17. Solderability
18. Heat or solvent bonding
19. Dielectric dissipation factor
20. Resistance to transformer oil
21. Loss of mass
22. High temperature failure
30. Packaging

This consolidated version consists of the third edition (1990),its amendment 1 (1997) and its amendment 2 (1997). Therefore, no need to order amendments in addition to this publication.

Committee
TC 55
DevelopmentNote
Also numbered as BS EN 60317-7. (10/2005)
DocumentType
Standard
Pages
15
PublisherName
International Electrotechnical Committee
Status
Withdrawn
Supersedes

I.S. EN 61858:2008 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
04/30113660 DC : DRAFT MAY 2004 IEC 60079-7 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY 'E'
BS EN 50019:2000 Electrical apparatus for potentially explosive atmospheres. Increased safety \'e\'
I.S. EN 60079-11:2012 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
ISA 60079-7 : 2008 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E"
BIS IS/IEC 60079-11 : 2006 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
NF EN 61858 : 2009 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
BS 6811-3.0(1993) : 1993 AMD 8984 WINDING WIRES - SPECIFICATIONS FOR PARTICULAR TYPES OF ROUND COPPER WINDING WIRES - GENERAL REQUIREMENTS
BS EN 61858:2008 Electrical insulation systems. Thermal evaluation of modifications to an established wire-wound EIS
NF EN 50020 : 2004 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INTRINSIC SAFETY 'I'
IEC 60034-18-22:2000 Rotating electrical machines - Part 18-22: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Classification of changes and insulation component substitutions
IEC 60079-11:2011 RLV Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
UNE-EN 60079-11:2013 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
EN 50020:2002 Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i'
BS EN 50020:2002 Electrical apparatus for potentially explosive atmospheres. Intrinsic safety \'i\'
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
BS EN 60079-11:2012 Explosive atmospheres Equipment protection by intrinsic safety \'i\'
08/30175787 DC : DRAFT JAN 2008 BS EN 60079-11 - EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY "I"
CSA E60079.7 : 2003 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY "E"
BIS IS/IEC 60079-7 : 2006 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
I.S. EN 50019:2001 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
IEC 61858:2008 Electrical insulation systems - Thermal evaluation of modifications to an established wire-wound EIS
EN 60079-11:2012 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
EN 50019:2000/corrigendum Apr. 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
EN 61858:2008 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
ISA 12.16.01 : 2002 ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - INCREASED SAFETY
CSA C22.2 No. 60079-11 : 2014 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'

IEC 60317-0-1:2013 Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.