1 Scope
2 Normative references
3 Terms and definitions
4 Design principles
4.1 Basic requirements related to functions
4.2 Measurement range
4.3 Energy response
4.4 Minimum detectable activity (or detection limit)
4.5 Precision (or repeatability)
4.6 Accuracy (or relative error)
4.7 Measurement time
4.8 Response time
4.9 Overload performance
4.10 Ambient background shielding or compensation devices
4.11 Requirements related to incident conditions
4.12 Reliability
4.13 User interface
4.13.1 General
4.13.2 Display of measured value
4.13.3 Alarms
4.13.4 Status indication
4.13.5 Local indications
4.14 System testing, maintenance facilities and ease of
decontamination
4.14.1 System testing
4.14.2 Maintenance facilities
4.14.3 Ease of decontamination
4.15 Electromagnetic interference
4.16 Power supplies
4.17 Interfaces
4.18 In-line detectors mechanical features
4.18.1 General requirements
4.18.2 Pressure-containing parts
4.18.3 Materials
4.18.4 Verification of material processing
4.19 Quality
4.20 Type test report and certificate
5 Functional testing
5.1 General
5.2 General test procedures
5.2.1 General
5.2.2 Tests performed under standard test conditions
5.2.3 Tests performed with variation of influence
quantities
5.2.4 Calculations and/or numerical simulations
5.2.5 Reference sources
5.2.6 Statistical fluctuations
5.3 Performance characteristics
5.3.1 Reference response
5.3.2 Accuracy (relative error)
5.3.3 Response to other artificial radionuclides
5.3.4 Response to background radiation
5.3.5 Precision (or repeatability)
5.3.6 Stability of the indication
5.3.7 Response time
5.3.8 Overload test
5.4 Electrical performance tests
5.4.1 Alarm trip range
5.4.2 Alarm trip stability
5.4.3 Fault alarm
5.4.4 Status indication and fault alarm tests
5.4.5 Warm-up time - Detection and measuring assembly
5.4.6 Influence of supply variations
5.4.7 Short circuit withstand tests
5.5 Environmental performance test
5.5.1 Stability of performance after storage
5.5.2 Mechanical tests
5.5.3 Stability of performance with variation of
ambient and stream conditions
5.5.4 Electromagnetic compatibility
Bibliography
IEC 60768:2009 provides criteria for the design, selection, testing, calibration and functional location of equipment for the monitoring of radioactive substances within plant-process streams during normal operation conditions and anticipated operational occurrences. Is only applicable to continuous in-line or on-line measurement. This new edition includes the following significant technical changes with respect to the previous edition:
- it clarifies the definitions;
- up-dates the reference to new standards published since the first issue;
- updates the units of radiation.
This publication is to be read in conjunction with IEC 60951-1:2009, IEC 60951-2:2009, IEC 60951-3:2009 and IEC 60951-4:2009.
Committee |
TC 45/SC 45A
|
DevelopmentNote |
To be read in conjunction with IEC 60951. (04/2009) Stability Date: 2019. (09/2017)
|
DocumentType |
Standard
|
Pages |
79
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
BS IEC 60768:2009 | Identical |
HD 462 : 200S1 | Identical |
NEN 10768 : 1988 | Identical |
UNE 21768:1996 | Identical |
16/30324061 DC : 0 | BS IEC 61504 ED2.0 - NUCLEAR FACILITIES INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - CENTRALIZED SYSTEMS FOR CONTINUOUS MONITORING OF RADIATION AND/OR LEVELS OF RADIOACTIVITY |
BS IEC 62705:2014 | Nuclear power plants. Instrumentation and control important to safety. Radiation monitoring systems (RMS): Characteristics and lifecycle |
13/30249610 DC : 0 | BS EN 62705 ED 1.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - RADIATION MONITORING SYSTEMS (RMS) CHARACTERISTICS AND TEST METHODS |
IEC 61504:2017 | Nuclear facilities - Instrumentation and control systems important to safety - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
IEC 60951-1:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 1: General requirements |
BS IEC 60951-1:2009 | Nuclear power plants. Instrumentation important to safety. Radiation monitoring for accident and post-accident conditions General requirements |
07/30172925 DC : 0 | BS IEC 60951-1 - NUCLEAR POWER PLANTS - INSTRUMENTATION IMPORTANT TO SAFETY - RADIATION MONITORING SYSTEM FOR ACCIDENT AND POST ACCIDENT CONDITIONS - PART 1: GENERAL REQUIREMENTS |
IEC 60532:2010 | Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV |
BS IEC 61559-1:2009 | Radiation protection instrumentation in nuclear facilities. Centralized systems for continuous monitoring of radiation and/or levels of radioactivity General requirements |
BS IEC 61504:2017 | Nuclear facilities. Instrumentation and control systems important to safety. Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
BS IEC 60532:2010 | Radiation protection instrumentation. Installed dose rate meters, warning assemblies and monitors. X and gamma radiation of energy between 50 keV and 7 MeV |
IEC 62705:2014 | Nuclear power plants - Instrumentation and control important to safety - Radiation monitoring systems (RMS): Characteristics and lifecycle |
IEEE 1819-2016 | IEEE Standard for Risk-Informed Categorization and Treatment of Electrical and Electronic Equipment at Nuclear Power Generating Stations and Other Nuclear Facilities |
IEC 61559-1:2009 | Radiation protection instrumentation in nuclear facilities - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity - Part 1: General requirements |
IEEE 338-2012 | IEEE Standard for Criteria for the Periodic Surveillance Testing of Nuclear Power Generating Station Safety |
IEC 60038:2009 | IEC standard voltages |
IEC 61226:2009 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
IEC 62138:2004 | Nuclear power plants - Instrumentation and control important for safety - Software aspects for computer-based systems performing category B or C functions |
IEC 61069-1:2016 | Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 1: Terminology and basic concepts |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60980:1989 | Recommended practices for seismic qualification of electrical equipment of the safety system for nuclear generating stations |
IEC 60987:2007+AMD1:2013 CSV | Nuclear power plants - Instrumentation and control important to safety - Hardware design requirements for computer-based systems |
IEC 60951-1:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 1: General requirements |
IEC 61559:1996 | Radiation in nuclear facilities - Centralized system for continuousmonitoring of radiation and/or levels of radiactivity |
IEC 61504:2017 | Nuclear facilities - Instrumentation and control systems important to safety - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 62302:2007 | Radiation protection instrumentation - Equipment for sampling and monitoring radioactive noble gases |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60861:2006 | Equipment for monitoring of radionuclides in liquid effluents and surface waters |
ISO 2889:2010 | Sampling airborne radioactive materials from the stacks and ducts of nuclear facilities |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60880:2006 | Nuclear power plants - Instrumentation and control systems important to safety - Software aspects for computer-based systems performing category A functions |
IEC 60780:1998 | Nuclear power plants - Electrical equipment of the safety system - Qualification |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
IEC 61513:2011 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 61000-4-18:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.