• There are no items in your cart

IEC 60931-3:1996

Current

Current

The latest, up-to-date edition.

Shunt capacitors of the non-self-healing type for AC power systems having a rated voltage up to and including 1000 V - Part 3: Internal fuses

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

19-08-1996

€41.59
Excluding VAT

Foreword
1 Scope and object
2 NOrmative reference
3 Definitions
4 Performance requirements
  4.1 General
  4.2 Disconnecting requirements
  4.3 Withstand requirements
5 Tests
  5.1 Routine tests
  5.2 Type tests
  5.3 Disconnecting test on fuses
Annexes
  A Test procedures for the disconnecting test
     on internal fuses
  B Guide for coordination of fuse protection

Applies to internal fuses which are designed to isolate faulty capacitor elements or capacitor unit, in order to allow operation of the remaining parts of that capacitor unit and the bank. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for external protection of the capacitor bank. This publication, together with IEC 60871-4 (1996) cancels and replaces IEC 60593 (1977).

DevelopmentNote
Supersedes IEC 60593 (03/2001) Also numbered as BS EN 60931-3. (12/2005) Stability Date: 2020. (09/2017)
DocumentType
Standard
Pages
19
PublisherName
International Electrotechnical Committee
Status
Current

NF EN 60931-1 : 97 AMD 1 2003 SHUNT POWER CAPACITORS OF THE NON-SELF HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
BS EN 60143-3:2015 Series capacitors for power systems Internal fuses
IEC 61921:2017 Power capacitors - Low-voltage power factor correction banks
11/30243422 DC : DRAFT FEB 2011 BS EN 60831-1 - SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
BS EN 60110-1:1998 Power capacitors for induction heating installations General
CEI EN 61921 : 2004 POWER CAPACITORS - LOW VOLTAGE POWER FACTOR CORRECTION BANKS
I.S. EN 60931-1:1997 SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AN INCLUDING 1 KV - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS GUIDE FOR INSTALLATION AND OPERATION
IEC TR 62001:2009 High-voltage direct current (HVDC) systems - Guidebook to the specification and design evaluation of A.C. filters
DD IEC/PAS 62001:2004 Guide to the specification and design evaluation of a.c. filters for HVDC systems
PD IEC/TR 62001:2009 High-voltage direct current (HVDC) systems. Guidebook to the specification and design evaluation of A.C. filters
I.S. EN 61921:2003 POWER CAPACITORS - LOW VOLTAGE POWER FACTOR CORRECTION BANKS
CEI EN 60871-1 : 2015 SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 1000 V - PART 1: GENERAL
IEC PAS 62001:2004 Guide to the specification and design evaluation of a.c. filters for HVDC systems
IEC 61921:2017 RLV Power capacitors - Low-voltage power factor correction banks
14/30300750 DC : 0 BS EN 60143-3 ED 2.0 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 3: INTERNAL FUSES
BS EN 61921:2003 Power capacitors. Low-voltage power factor correction banks
BS EN 60931-1:1998 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV General. Performance, testing and rating. Safety requirements. Guide for installation and operation
IEC TR 62001-4:2016 High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 4: Equipment
BS 7578:1992 Coupling capacitors and capacitor dividers
PD IEC/TR 62001-4:2016 High-voltage direct current (HVDC) systems. Guidance to the specification and design evaluation of AC filters Equipment
I.S. EN 60143-3:2015 SERIES CAPACITORS FOR POWER SYSTEMS - PART 3: INTERNAL FUSES
IEC 60143-3:2015 Series capacitors for power systems - Part 3: Internal fuses
EN 60931-1:1996/A1:2003 SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1 KV - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
EN 61921:2003 Power capacitors - Low-voltage power factor correction banks
EN 60143-3:2015 Series capacitors for power systems - Part 3: Internal fuses
CSA C60871.1 : 2014 SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 1000 V - PART 1: GENERAL

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.