IEC 61000-4-33:2005
Current
The latest, up-to-date edition.
Electromagnetic compatibility (EMC) - Part 4-33: Testing and measurement techniques - Measurement methods for high-power transient parameters
Hardcopy , PDF
English
27-09-2005
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Measurement of high-power transient responses
4.1 Overall measurement concepts and requirements
4.2 Representation of a measured response
4.3 Measurement equipment
4.4 Measurement procedures
5 Measurement of low frequency responses
6 Calibration procedures
6.1 Calibration of the entire measurement channel
6.2 Calibration of individual measurement channel components
6.3 Approximate calibration techniques
Annex A (normative) Methods of characterizing measured responses
Annex B (informative) Characteristics of measurement sensors
Annex C (normative) HPEM measurement procedures
Annex D (informative) Two-port representations of measurement
chain components
Bibliography
Provides a basic description of the methods and means (e.g., instrumentation) for measuring responses arising from high-power transient electromagnetic parameters. These responses can include: - the electric (E) and/or magnetic (H) fields (e.g., incident fields or incident plus scattered fields within a system under test); - the current I (e.g., induced by a transient field or within a system under test); - the voltage V (e.g., induced by a transient field or within a system under test); - the charge Q induced on a cable or other conductor. These measured quantities are generally complicated time-dependent waveforms, which can be described approximately by several scalar parameters, or "observables". These parameters include: - the peak amplitude of the response, - the waveform rise-time, - the pulse width, and - mathematically defined norms obtained from the waveform. This International Standard provides information on the measurement of these waveforms and on the mathematical determination of the characterizing parameters. It does not provide information on specific level requirements for testing. It has the status of a basic EMC publication in accordance with IEC Guide 107.
| Committee |
TC 77/SC 77C
|
| DevelopmentNote |
Stability Date: 2018. (11/2017)
|
| DocumentType |
Standard
|
| Pages |
69
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Current
|
| Standards | Relationship |
| IS 14700 : Part 4 : Sec 33 : 2018 | Identical |
| IEEE DRAFT 1309 : D2.0 2005 | CALIBRATION OF ELECTROMAGNETIC FIELD SENSORS AND PROBES, EXCLUDING ANTENNAS, FROM 9 KHZ TO 40 GHZ |
| 13/30286075 DC : 0 | BS EN 61000-4-36 ED 1.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-36: TESTING AND MEASUREMENT TECHNIQUES - IEMI IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS |
| DEFSTAN 59-188(PT2)/1(2010) : 2010 | HIGH ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND BASED COMMUNICATION FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS - PART 2: TRANSPORTABLE AND MOBILE SYSTEMS |
| DEFSTAN 59-188(PT2)/2(2017) : 2017 | HIGH ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND BASED COMMUNICATION FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS - PART 2: TRANSPORTABLE AND MOBILE SYSTEMS |
| I.S. EN 61000-4-25:2002 | ELECTROMAGNETIC COMPATIBILITY (EMC) - TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS (IEC 61000-4-25:2001 (EQV)) |
| IEC TS 61000-5-8:2009 | Electromagnetic compatibility (EMC) - Part 5-8: Installation and mitigation guidelines - HEMP protection methods for the distributed infrastructure |
| PD IEC/TS 61000-5-10:2017 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI |
| 03/107918 DC : DRAFT MAY 2003 | IEC 61000-4-1 ED.2 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-1: TESTING AND MEASUREMENT TECHNIQUES - OVERVIEW OF IEC 61000-4 SERIES |
| IEC TS 61000-5-9:2009 | Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM |
| IEC 61000-4-24:2015 | Electromagnetic compatibility (EMC) - Part 4-24: Testing and measurement techniques - Test methods for protective devices for HEMP conducted disturbance |
| IEC 61000-4-36:2014 | Electromagnetic compatibility (EMC) - Part 4-36: Testing and measurement techniques - IEMI immunity test methods for equipment and systems |
| 08/30181498 DC : DRAFT APR 2008 | BS EN 61000-5-8 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5-8: INSTALLATION AND MITIGATION GUIDELINES - HEMP PROTECTION METHODS FOR THE DISTRIBUTED INFRASTRUCTURE |
| BS EN 61000-4-25 : 2002 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-25: TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS |
| IEEE 1309-2013 REDLINE | IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHz |
| DD IEC/TS 61000-5-9:2009 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines. System-level susceptibility assessments for HEMP and HPEM |
| BS EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Overview of IEC 61000-4 series |
| DD IEC/TS 61000-5-8:2009 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines. HEMP protection methods for the distributed infrastructure |
| NF EN 61000-4-1 : 2007 | |
| 13/30285924 DC : 0 | BS EN 61000-4-24 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-24: TESTING AND MEASUREMENT TECHNIQUES - TEST METHODS FOR PROTECTIVE DEVICES FOR HEMP CONDUCTED DISTURBANCE |
| BS IEC 61000-4-36:2014 | Electromagnetic compatibility (EMC) Testing and measurement techniques. IEMI immunity test methods for equipment and systems |
| IEC TR 61000-4-1:2016 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
| I.S. EN 61000-4-1:2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-1: TESTING AND MEASUREMENT TECHNIQUES - OVERVIEW OF IEC 61000-4 SERIES |
| IEC 61000-4-25:2001+AMD1:2012 CSV | Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems |
| IEC TS 61000-5-10:2017 | Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI |
| EN 61000-4-25 : 2002 AMD 1 2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-25: TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS (IEC 61000-4-25:2001/A1:2012) |
| 11/30244471 DC : 0 | BS EN 61000-4-25 AMD. ED - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-25: TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS |
| IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
| EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
| AS IEC 62040.2:2019 | Uninterruptible power systems (UPS) Electromagnetic compatibility (EMC) requirements |
| IEC 61000-2-10:1998 | Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance |
| IEC 61000-2-11:1999 | Electromagnetic compatibility (EMC) - Part 2-11: Environment - Classification of HEMP environments |
| SA TR IEC 61000.2.5:2019 | Electromagnetic compatibility (EMC) Environment - Description and classification of electromagnetic environments |
| IEC 61000-4-25:2001+AMD1:2012 CSV | Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems |
| IEC 61000-4-20:2010 | Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides |
| IEC 61000-2-9:1996 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance. Basic EMC publication |
| IEC 61000-4-23:2016 | Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.