IEC 61400-25-4:2016
Current
The latest, up-to-date edition.
Wind energy generation systems - Part 25-4: Communications for monitoring and control of wind power plants - Mapping to communication profile
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
30-11-2016
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 General overview
Annex A (normative) - Specific communication
service mapping - Definition and mapping
to Web Services
Annex B (normative) - Specific communication
service mapping - Mapping to OPC XML-DA
Annex C (normative) - Specific communication
service mapping - Mapping to ISO 9506
specified in IEC 61850-8-1
Annex D (normative) - Specific communication
service mapping - Mapping to IEC 60870-5-104
specified in IEC TS 61850-80-1
Annex E (normative) - Specific communication
service mapping - Mapping to DNP3
Annex F (normative) - Time synchronization
Annex G (informative) - Interfaces - Implementation
considerations
Bibliography
IEC 61400-25-4:2016 specifies the specific mappings to protocol stacks encoding the messages required for the information exchange between a client and a remote server for: data access and retrieval, device control, event reporting and logging, publisher/subscriber, self-description of devices (device data dictionary), data typing and discovery of data types. The mappings specified in this part of IEC 61400-25 comprise:
- a mapping to SOAP-based web services,
- a mapping to OPC/XML-DA,
- a mapping to IEC 61850-8-1 MMS,
- a mapping to IEC 60870-5-104,
- a mapping to DNP3.
The main technical changes with regard to the previous edition are as follows:
- general harmonization with information models in IEC 61400-25-2 and information exchange services in IEC 61400-25-3;
- reduction of overlap between standards and simplification by increased referencing.
Committee |
TC 88
|
DevelopmentNote |
PDF along with software file available in ZIP format. Stability Date: 2018. (12/2016)
|
DocumentType |
Standard
|
Pages |
488
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN 61400-25-4 : 2017 | Identical |
IS/IEC 61400 : Part 25 : Sec 4 : 2016 | Identical |
PN EN 61400-25-4 : 2017 | Identical |
SN EN 61400-25-4 : 2017 | Identical |
DIN EN 61400-25-4 : 2009 | Identical |
VDE 0127-25-4 : 2017 | Identical |
CEI EN 61400-25-4 : 2009 | Identical |
EN 61400-25-4:2017 | Identical |
NF EN 61400-25-4 : 2017 | Identical |
UNE-EN 61400-25-4:2017 | Identical |
UNE-EN 61400-25-4:2009 | Identical |
BS EN 61400-25-4:2017 | Identical |
BS EN 61400-25-4:2008 | Identical |
BS EN 60891:2010 | Identical |
PNE-FprEN 61400-25-4 | Identical |
NEN EN IEC 61400-25-4 : 2017 | Identical |
SAC GB/T 30966-4 : 2014 | Identical |
16/30340907 DC : 0 | BS EN 61400-25-6 ED 2.0 - WIND TURBINES - PART 25-6: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - LOGICAL NODE CLASSES AND DATA CLASSES FOR CONDITION MONITORING |
NF EN 61400-25-3 : 2016 | WIND TURBINES - PART 25-3: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - INFORMATION EXCHANGE MODELS |
BS EN 61400-25-1:2017 | Wind energy generation systems Communications for monitoring and control of wind power plants. Overall description of principles and models |
CEI EN 61400-25-6 : 2011 | WIND ENERGY GENERATION SYSTEMS - PART 25-6: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - LOGICAL NODE CLASSES AND DATA CLASSES FOR CONDITION MONITORING |
EN 61400-25-5:2017 | Wind energy generation systems - Part 25-5: Communications for monitoring and control of wind power plants - Compliance testing |
I.S. EN 61400-25-6:2017 | WIND ENERGY GENERATION SYSTEMS - PART 25-6: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - LOGICAL NODE CLASSES AND DATA CLASSES FOR CONDITION MONITORING |
CLC/TS 61400-26-3:2017 | Wind energy generation systems - Part 26-3: Availability for wind power stations |
EN 61400-25-1:2017 | Wind energy generation systems - Part 25-1: Communications for monitoring and control of wind power plants - Overall description of principles and models |
IEC 61400-25-3:2015 RLV | Wind turbines - Part 25-3: Communications for monitoring and control of wind power plants - Information exchange models |
EN 61400-25-6:2017 | Wind energy generation systems - Part 25-6: Communications for monitoring and control of wind power plants - Logical node classes and data classes for condition monitoring |
UFC 3-540-08 : 2017 | UNIFIED FACILITIES CRITERIA - UTILITY-SCALE RENEWABLE ENERGY SYSTEMS |
05/30137801 DC : DRAFT AUG 2005 | IEC 61400-25-2 ED 1 - WIND TURBINES - PART 25-2: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - INFORMATION MODELS |
PD IEC/TR 62351-10:2012 | Power systems management and associated information exchange. Data and communications security Security architecture guidelines |
I.S. EN 61400-25-2:2015 | WIND TURBINES - PART 25-2: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - INFORMATION MODELS |
BS EN 61400-25-2:2015 | Wind turbines Communications for monitoring and control of wind power plants - Information models |
08/30184178 DC : DRAFT JUNE 2008 | BS EN 61400-25-6 - WIND TURBINES - PART 25-6: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - LOGICAL NODE CLASSES AND DATA CLASSES FOR CONDITION MONITORING |
CLC/TS 61400-26-1:2017 | Wind turbines - Part 26-1: Time-based availability for wind turbine generating systems |
PD CLC/TS 61400-26-2:2017 | Wind turbines Production-based availability for wind turbines |
IEC 61400-25-1:2017 | Wind energy generation systems - Part 25-1: Communications for monitoring and control of wind power plants - Overall description of principles and models |
IEC TR 62351-10:2012 | Power systems management and associated information exchange - Data and communications security - Part 10: Security architecture guidelines |
IEC TS 61400-26-2:2014 | Wind turbines - Part 26-2: Production-based availability for wind turbines |
CLC/TS 61400-26-2:2017 | Wind turbines - Part 26-2: Production-based availability for wind turbines |
PD CLC/TS 61400-26-1:2017 | Wind turbines Time-based availability for wind turbine generating systems |
BS EN 61400-25-6:2017 | Wind energy generation systems Communications for monitoring and control of wind power plants. Logical node classes and data classes for condition monitoring |
BS PD IEC TS 61400-26-2 : 2014 | WIND TURBINES - PART 26-2: PRODUCTION-BASED AVAILABILITY FOR WIND TURBINES |
IEC TS 61400-26-1:2011 | Wind turbines - Part 26-1: Time-based availability for wind turbine generating systems |
I.S. EN 61400-25-5:2017 | WIND ENERGY GENERATION SYSTEMS - PART 25-5: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - COMPLIANCE TESTING |
I.S. EN 61400-25-3:2015 | WIND TURBINES - PART 25-3: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - INFORMATION EXCHANGE MODELS |
S.R. CLC/TS 61400-26-1:2017 | WIND TURBINES - PART 26-1: TIME-BASED AVAILABILITY FOR WIND TURBINE GENERATING SYSTEMS |
IEC 61400-25-2:2015 | Wind turbines - Part 25-2: Communications for monitoring and control of wind power plants - Information models |
IEC 61400-25-3:2015 | Wind turbines - Part 25-3: Communications for monitoring and control of wind power plants - Information exchange models |
IEC TS 61400-26-3:2016 | Wind energy generation systems - Part 26-3: Availability for wind power stations |
EN 61400-25-3:2015 | Wind turbines - Part 25-3: Communications for monitoring and control of wind power plants - Information exchange models |
PD CLC/TS 61400-26-3:2017 | Wind energy generation systems Availability for wind power stations |
05/30137813 DC : DRAFT AUG 2005 | IEC 61400-25-5 ED 1 - WIND TURBINES - PART 25-5: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - CONFORMANCE TESTING |
BS EN 61400-25-3:2015 | Wind turbines Communications for monitoring and control of wind power plants. Information exchange models |
DD IEC TS 61400-26-1 : 2011 | WIND TURBINES - PART 26-1: TIME-BASED AVAILABILITY FOR WIND TURBINE GENERATING SYSTEMS |
PD IEC/TS 61400-26-3:2016 | Wind energy generation systems Availability for wind power stations |
S.R. CLC/TS 61400-26-2:2017 | WIND TURBINES - PART 26-2: PRODUCTION-BASED AVAILABILITY FOR WIND TURBINES |
BS EN 61400-25-5:2017 | Wind energy generation systems Communications for monitoring and control of wind power plants. Compliance testing |
I.S. EN 61400-25-1:2017 | WIND ENERGY GENERATION SYSTEMS - PART 25-1: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - OVERALL DESCRIPTION OF PRINCIPLES AND MODELS |
S.R. CLC/TS 61400-26-3:2017 | WIND ENERGY GENERATION SYSTEMS - PART 26-3: AVAILABILITY FOR WIND POWER STATIONS |
IEC 61400-25-5:2017 | Wind energy generation systems - Part 25-5: Communications for monitoring and control of wind power plants - Compliance testing |
IEC 61400-25-6:2016 | Wind energy generation systems - Part 25-6: Communications for monitoring and control of wind power plants - Logical node classes and data classes for condition monitoring |
IEC 61400-25-1:2017 RLV | Wind energy generation systems - Part 25-1: Communications for monitoring and control of wind power plants - Overall description of principles and models |
EN 61400-25-2:2015 | Wind turbines - Part 25-2: Communications for monitoring and control of wind power plants - Information models |
IEC 61850-7-2:2010 | Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI) |
ISO 9506-2:2003 | Industrial automation systems Manufacturing Message Specification Part 2: Protocol specification |
ISO/IEC 10646:2014 | Information technology Universal Coded Character Set (UCS) |
ISO/IEC 8825-1:2015 | Information technology ASN.1 encoding rules: Specification of Basic Encoding Rules (BER), Canonical Encoding Rules (CER) and Distinguished Encoding Rules (DER) Part 1: |
ISO/IEC 8823-1:1994 | Information technology Open Systems Interconnection Connection-oriented presentation protocol: Protocol specification |
IEC 62439-3:2016 | Industrial communication networks - High availability automation networks - Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) |
IEC 60870-5-4:1993 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 4: Definition and coding of application information elements |
IEC 61850-6:2009 | Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs |
IEC 60870-5-104:2006+AMD1:2016 CSV | Telecontrol equipment and systems - Part 5-104: Transmission protocols - Network access for IEC 60870-5-101 using standardtransport profiles |
ISO/IEC 8327-1:1996 | Information technology Open Systems Interconnection Connection-oriented Session protocol: Protocol specification |
IEEE 802.1D-2004 | IEEE Standard for Local and metropolitan area networks: Media Access Control (MAC) Bridges |
IEC TR 61850-1:2013 | Communication networks and systems for power utility automation - Part 1: Introduction and overview |
ISO 9506-1:2003 | Industrial automation systems Manufacturing Message Specification Part 1: Service definition |
IEC 60870-5-101:2003+AMD1:2015 CSV | Telecontrol equipment and systems - Part 5-101: Transmissionprotocols - Companion standard for basic telecontrol tasks |
IEC 60870-5-5:1995 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 5: Basic application functions |
IEC 61850-7-1:2011 | Communication networks and systems for power utility automation - Part 7-1: Basic communication structure - Principles and models |
IEC 61850-8-1:2011 | Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 |
IEC 61400-25-1:2017 | Wind energy generation systems - Part 25-1: Communications for monitoring and control of wind power plants - Overall description of principles and models |
ISO 639-2:1998 | Codes for the representation of names of languages — Part 2: Alpha-3 code |
IEC 61400-25-3:2015 | Wind turbines - Part 25-3: Communications for monitoring and control of wind power plants - Information exchange models |
IEC 61850-7-3:2010 | Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes |
IEC TS 61850-80-1:2016 | Communication networks and systems for power utility automation - Part 80-1: Guideline to exchanging information from a CDC-based data model using IEC 60870-5-101 or IEC 60870-5-104 |
ISO/IEC 8824-1:2015 | Information technology Abstract Syntax Notation One (ASN.1): Specification of basic notation Part 1: |
ISO/IEC 8650-1:1996 | Information technology Open Systems Interconnection Connection-oriented protocol for the Association Control Service Element: Protocol specification |
ISO/IEC 8649:1996 | Information technology Open Systems Interconnection Service definition for the Association Control Service Element |
IEEE 754-2008 REDLINE | IEEE Standard for Floating-Point Arithmetic |
IEC 60870-5-3:1992 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 3: General structure of application data |
IEC 61400-25-2:2015 | Wind turbines - Part 25-2: Communications for monitoring and control of wind power plants - Information models |
ISO/IEC 8822:1994 | Information technology Open Systems Interconnection Presentation service definition |
IEEE 1815-2012 REDLINE | IEEE Standard for Electric Power Systems Communications-Distributed Network Protocol (DNP3) |
ISO/IEC 8326:1996 | Information technology Open Systems Interconnection Session service definition |
IEC 61400-25-5:2017 | Wind energy generation systems - Part 25-5: Communications for monitoring and control of wind power plants - Compliance testing |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.