• Shopping Cart
    There are no items in your cart

IEC 62067:2011 RLV

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 500 kV (Um = 550 kV) - Test methods and requirements

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

21-04-2022

Language(s)

English

Published date

24-11-2011

€358.68
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Voltage designations and materials
5 Precautions against water penetration in cables
6 Cable characteristics
7 Accessory characteristics
8 Test conditions
9 Routine tests on cables and on the main insulation of
   prefabricated accessories
10 Sample tests on cables
11 Sample tests on accessories
12 Type tests on cable systems
13 Prequalification test of the cable system
14 Type test on cables
15 Type test on accessories
16 Electrical test after installation
Annex A (informative) - Determination of the cable conductor
        temperature
Annex B (normative) - Rounding of numbers
Annex C (informative) - List of type and prequalification and
        extension of prequalification tests of cable systems
Annex D (normative) - Method of measuring resistivity of
        semi-conducting screens
Annex E (normative) - Water penetration test
Annex F (normative) - Tests on components of cables with a
        longitudinally applied metal tape or foil, bonded to
        the oversheath
Annex G (normative) - Tests of outer protection for joints
Bibliography

IEC 62067:2011 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 62067:2011 specifies test methods and requirements for power cable systems, cables with extruded insulation and their accessories for fixed installations, for rated voltages above 150 kV (Um = 170 kV) up to and including 500 kV (Um = 550 kV). The requirements apply to single-core cables and to their accessories for usual conditions of installation and operation, but not to special cables and their accessories, such as submarine cables, for which modifications to the standard tests may be necessary or special test conditions may need to be devised. This standard does not cover transition joints between cables with extruded insulation and paper insulated cables. The significant technical changes with respect to the previous edition are as follows:
- addition of the extension of prequalification test, requiring significant less time to be completed compared with the full prequalification test;
- during the routine tests on the main insulation of prefabricated accessories the required sensitivity level for the partial discharge test is reduced from 10 pC to 5 pC.
NOTE: For a more detailed history of events leading up to this second edition, see the introduction.

Committee
TC 20
DevelopmentNote
Stability Date: 2018. (11/2017)
DocumentType
Redline
Pages
188
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
DIN IEC 62067 : 2013 Identical
NEN IEC 62067 : 2011 Identical
VDE 0276-2067 : 2013 Identical
SAC GB/Z 18890-1 : 2002 Identical
GOST R IEC 62067 : 2011 Identical
UNE 211004:2003 Identical

UNE-EN 50299-1:2015 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 1: Fluid-filled cable terminations
EN 62271-209:2007 High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations
EN 50299-1:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 1: Fluid-filled cable terminations
UNE-EN 50299-2:2015 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations
CSA C22.3 No. 7 : 2015 UNDERGROUND SYSTEMS
EN 50299-2:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations
IEEE 1727-2013 IEEE Guide for Working Procedures on Underground Transmission Circuits with Induced Voltage
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
NF EN 62271-209 : 2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY TYPE CABLE-TERMINATIONS
BS EN 62271-203:2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC TR 61901:2016 Tests recommended on cables with a longitudinally applied metal foil for rated voltages above 30 kV (U<sub>m</sub> = 36 kV) up to and including 500 kV (U<sub>m</sub> = 550 kV)
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
IEC 61443:1999+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV)
IEEE 400-2012 REDLINE IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above
BS EN 62271-209:2007 High-voltage switchgear and controlgear Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. Fluid-filled and extruded insulation cables. Fluid-filled and dry-type cable-terminations
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
BS EN 50299-2:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Dry-type cable terminations
UNE-EN 62271-203:2013 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
BS EN 50299-1:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Fluid-filled cable terminations
IEC 62271-209:2007 High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations
BS IEC 62895:2017 High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements
BIS IS/IEC 62271-203 : 2003 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
IEEE 1793:2012 GUIDE FOR PLANNING AND DESIGNING TRANSITION FACILITIES BETWEEN OVERHEAD AND UNDERGROUND TRANSMISSION LINES
I.S. EN 62271-203:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV))
IEEE 400.4-2015 IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage

IEC 60811-3-1:1985 Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking
IEC 60228:2004 Conductors of insulated cables
IEC 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
IEC 60885-3:2015 RLV Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
IEC 60230:1966 Impulse tests on cables and their accessories
IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
IEC 60853-2:1989 Calculation of the cyclic and emergency current rating of cables. Part 2: Cyclic rating of cables greater than 18/30 (36) kV and emergency ratings for cables of all voltages
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
IEC 60229:2007 Electric cables - Tests on extruded oversheaths with a special protective function
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
IEC 60811-3-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 3: Methods specific to PVC compounds - Section Two: Loss of mass test - Thermal stability test
IEC 60287-1-1:2006+AMD1:2014 CSV Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.