FOREWORD
1 Scope
2 Normative references
3 Symbols interpretation
4 Electromagnetic phenomena
5 The intrinsic screening parameters of short cables
6 Long cables - coupled transmission lines
7 Transfer impedance of a braided wire outer conductor
   or screen
8 Test possibilities
9 Comparison of the frequency response of different
   triaxial test set-ups to measure the transfer impedance
   of cable screens
10 Background of the shielded screening attenuation
   test method (IEC 62153-4-4)
11 Background of the shielded screening attenuation
   test method for measuring the screening effectiveness
   of feed-throughs and electromagnetic gaskets
   (IEC 62153-4-10)
12 Background of the shielded screening attenuation test
   method for measuring the screening effectiveness
   of RF connectors and assemblies (IEC 62153-4-7)
Bibliography

IEC TS 62153-4-1:2014(E) deals with screening measurements. Screening (or shielding) is one basic way of achieving electromagnetic compatibility (EMC). However, a confusingly large number of methods and concepts is available to test for the screening quality of cables and related components, and for defining their quality. This technical specification gives a brief introduction to basic concepts and terms trying to reveal the common features of apparently different test methods. It is intended to assist in correct interpretation of test data, and in the better understanding of screening (or shielding) and related specifications and standards. This technical specification cancels and replaces the second edition of the technical report IEC/TR 62153-4-1 published in 2010.

Committee
TC 46
DevelopmentNote
Supersedes IEC TR 62153-4-1. Stability date: 2017. (01/2014)
DocumentType
Technical Specification
Pages
105
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NEN NPR IEC/TS 62153-4-1 : 2014 Identical
PD IEC TS 62153-4-1:2014+A1:2020 Identical

I.S. EN 61726:2015 CABLE ASSEMBLIES, CABLES, CONNECTORS AND PASSIVE MICROWAVE COMPONENTS - SCREENING ATTENUATION MEASUREMENT BY THE REVERBERATION CHAMBER METHOD
IEC 62153-4-16:2016 Metallic communication cable test methods - Part 4-16: Electromagnetic compatibility (EMC) - Extension of the frequency range to higher frequencies for transfer impedance and to lower frequencies for screening attenuation measurements using the triaxial set-up
IEC 62153-4-9:2018 RLV Metallic communication cable test methods - Part 4 - 9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method
IEC 62153-4-6:2017 RLV Metallic cables and other passive components test methods - Part 4-6: Electromagnetic compatibility (EMC) - Surface transfer impedance - Line injection method
15/30334758 DC : 0 BS IEC 62153-4-16 ED 1.0 - I METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-16: EXTENSION OF THE FREQUENCY RANGE TO HIGHER FREQUENCIES FOR TRANSFER IMPEDANCE AND TO LOWER FREQUENCIES FOR SCREENING ATTENUATION MEASUREMENTS USING THE TRIAXIAL SET-UP
17/30348794 DC : 0 BS EN 62153-4-7+A1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE ZT AND SCREENING ATTENUATION AS OR COUPLING ATTENUATION AC OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD
IEC 61726:2015 Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method
IEC 62153-4-10:2015 Metallic communication cable test methods - Part 4-10: Electromagnetic compatibility (EMC) - Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets - Double coaxial test method
IEC 62153-4-4:2015 Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
I.S. EN 62153-4-7:2016 METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD
IEC 62153-4-15:2015 Metallic communication cable test methods - Part 4-15: Electromagnetic compatibility (EMC) - Test method for measuring transfer impedance and screening attenuation - or coupling attenuation with triaxial cell
EN 62153-4-7:2016/AC:2016-05 METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD (IEC 62153-4-7:2015/COR1:2016)
BS IEC 62153-4-10:2015 Metallic communication cable test methods Electromagnetic compatibility (EMC). Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets. Double coaxial test method
BS IEC 62153-4-15:2015 Metallic Communication Cable test methods Electromagnetic compatibility (EMC). Test method for measuring transfer impedance and screening attenuation or coupling attenuation with triaxial cell
BS EN 61726:2000 Cable assemblies, cables, connectors and passive microwave components. Screening attenuation measurement by the reverberation chamber method
IEC 62153-4-9:2008 Metallic communication cable test methods - Part 4-9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method
BS IEC 62153-4-6:2017 Metallic cables and other passive components test methods Electromagnetic compatibility (EMC). Surface transfer impedance. Line injection method
BS EN 62153-4-7 : 2016 METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD
BS IEC 62153-4-16:2016 Metallic communication cable test methods Electromagnetic compatibility (EMC). Extension of the frequency range to higher frequencies for transfer impedance and to lower frequencies for screening attenuation measurements using the triaxial set-up
UNE-EN 61726:2016 Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method
IEC 62153-4-6:2017 Metallic cables and other passive components test methods - Part 4-6: Electromagnetic compatibility (EMC) - Surface transfer impedance - Line injection method
IEC 62153-4-7:2015 Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling attenuation a<sub>C</sub> of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method
EN 61726:2015 Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method
CEI EN 62153-4-16:2022 Metallic cables and other passive components test methods Part 4-16: Electromagnetic compatibility (EMC) - Extension of the frequency range to higher frequencies for transfer impedance and to lower frequencies for screening attenuation measurements using the triaxial set-up

IEC 62153-4-3:2013 Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method
IEC 62153-4-7:2015 Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling attenuation a<sub>C</sub> of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method
EN 50289-1-6:2002 Communication cables - Specifications for test methods - Part 1-6: Electrical test methods - Electromagnetic performance
IEC 62153-4-2:2003 Metallic communication cable test methods - Part 4-2: Electromagnetic compatibility (EMC) - Screening and coupling attenuation - Injection clamp method
IEC TR 62152:2009 Transmission properties of cascaded two-ports or quadripols - Background of terms and definitions
CISPR 25:2016 Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
IEC 62153-4-4:2015 Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
IEC 60169-1-3:1988 Radio-frequency connectors - Part 1: General requirements and measuring methods - Section Three: Electrical tests and measuring procedures: Screening effectiveness
IEC 61196-1:2005 Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements
IEC 62153-4-6:2017 Metallic cables and other passive components test methods - Part 4-6: Electromagnetic compatibility (EMC) - Surface transfer impedance - Line injection method
IEC 62153-4-5:2006 Metallic communication cables test methods - Part 4-5: Electromagnetic compatibility (EMC) - Coupling or screening attenuation - Absorbing clamp method
IEC 60096-4-1:1990 Radio-frequency cables. Part 4: Specification for superscreened cables - Section One: General requirements and test methods
IEC 61726:2015 Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method
IEC 62153-4-10:2015 Metallic communication cable test methods - Part 4-10: Electromagnetic compatibility (EMC) - Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets - Double coaxial test method

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.