IEEE C37.103-2015 REDLINE
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
IEEE Guide for Differential and Polarizing Relay Circuit Testing
Hardcopy , PDF
English
17-12-2015
26-03-2026
1 Overview
2 Normative references
3 Definitions
4 Operating considerations for personnel
and equipment
5 Preparatory tests
6 Power sources for tests
7 Generator, motor, and reactor differential
relaying
8 Bus differential relaying
9 Transformer differential relaying
10 Potential-polarized phase relays
11 Potential-polarized ground relays
12 Neutral-current-polarized ground relays
13 Tertiary current-polarized ground relays
14 Transformer ground differential (restricted
earth fault) relays
15 Conclusion
Annex A (informative) - Aids to differential
relay load checks
Annex B (informative) - Bibliography
This guide covers tests to help ensure correct connections of differential relays and polarizing circuits of phase and ground relays.
| Committee |
Power System Relaying and Control
|
| DocumentType |
Standard
|
| ISBN |
978-1-5044-0090-9
|
| Pages |
143
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Withdrawn
|
| Supersedes |
| IEEE C57.13.3-2014 REDLINE | IEEE Guide for Grounding of Instrument Transformer Secondary Circuits and Cases |
| IEEE DRAFT C57.13.3 : D9 2005 | GUIDE FOR GROUNDING OF INSTRUMENT TRANSFORMER SECONDARY CIRCUITS AND CASES |
| IEEE DRAFT C37.91 : D7.0 2006 | PROTECTING POWER TRANSFORMERS |
| IEEE C37.91-2008 REDLINE | IEEE Guide for Protecting Power Transformers |
| IEEE C37.233 : 2009 | GUIDE FOR POWER SYSTEM PROTECTION TESTING |
| IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) (Color Book® Series) |
| IEEE DRAFT C37.110 : D21 OCT 94 | GUIDE FOR THE APPLICATION OF CURRENT TRANSFORMERS USED FOR PROTECTIVE RELAYING PURPOSES |
| IEEE C37.13.1-2006 | IEEE Standard for Definite Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear |
| IEEE C37.110-2007 REDLINE | IEEE Guide for the Application of Current Transformers Used for Protective Relaying Purposes |
| IEEE C57.13.3-2014 REDLINE | IEEE Guide for Grounding of Instrument Transformer Secondary Circuits and Cases |
| IEEE C37.233 : 2009 | GUIDE FOR POWER SYSTEM PROTECTION TESTING |
| IEEE C57.131-2012 | IEEE Standard Requirements for Tap Changers |