IEEE C57.18.10 : 1998
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
PRACTICES AND REQUIREMENTS FOR SEMICONDUCTOR POWER RECTIFIER TRANSFORMERS
Hardcopy , PDF
01-01-1998
16-03-2026
1 Overview
1.1 Scope
1.2 Mandatory requirements
2 References
3 Definitions
4 Symbols
5 Service conditions
5.1 Usual service conditions
5.2 Unusual service conditions
6 Rating data
6.1 Taps of rectifier transformers
6.2 Cooling classes of transformers
6.3 Frequency
6.4 Phase
6.5 Rated kVA
6.6 Compensation on rectifier transformers
6.7 Rated current
6.8 Connections
6.9 Polarity, angular displacement, and lead markings
6.10 Impedance
6.11 Losses
6.12 Temperature rise and insulation system capability
6.13 Nameplates
7 Construction
7.1 Mounting and location
7.2 Tanks
7.3 Methods of coolant preservation
7.4 Grounding
7.5 Connections for shipping
7.6 Accessories
8 Testing and calculations
8.1 Routine tests
8.2 Symbols used in tests
8.3 Resistance measurement
8.4 Dielectric tests
8.5 Excitation losses
8.6 Load losses
8.7 Losses in interphase transformers
8.8 Impedance tests
8.9 Ratio tests
8.10 Temperature rise test
8.11 Short-circuit tests
8.12 Polarity and phase relation
9 Tolerances
9.1 Tolerances for ratio
9.2 Tolerances for impedance
9.3 Tolerances for losses
Annex A (informative) Harmonic loss calculation examples
Annex B (informative) Bibliography
Develops a standard for transformers serving semi-conductor power rectifiers employing monocrystal-line semiconductor diodes or thyristors.
| DevelopmentNote |
Supersedes IEEE DRAFT C57.18.10. (11/1999) Amendment 1 to IEEE C57.18.10 is available separately, see IEEE C57.18.10A. (08/2008)
|
| DocumentType |
Standard
|
| Pages |
71
|
| ProductNote |
New child AMD 1 2008 added
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| IEEE 1653.2-2009 | IEEE Standard for Uncontrolled Traction Power Rectifiers for Substation Applications Up to 1500 V DC Nominal Output |
| IEC/IEEE 60076-57-129:2017 | Power transformers - Part 57-129: Transformers for HVDC applications |
| IEEE 421.4-2014 | IEEE Guide for the Preparation of Excitation System Specifications |
| IEEE 1566-2015 REDLINE | IEEE Standard for Performance of Adjustable-Speed AC Drives Rated 375 kW and Larger |
| IEEE C57.110-2008 REDLINE | IEEE Recommended Practice for Establishing Liquid-Filled and Dry-Type Power and Distribution Transformer Capability When Supplying Nonsinusoidal Load Currents |
| 16/30336914 DC : 0 | BS EN 60076-57-129 ED 1.0 - CONVERTOR TRANSFORMERS - PART 57-129: TRANSFORMERS FOR HVDC APPLICATIONS |
| I.S. EN ISO 14224:2016 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT (ISO 14224:2016) |
| IEEE C57.12.70-2011 | IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers |
| IEEE C57.17-2012 | IEEE Standard Requirements for Arc Furnace Transformers |
| IEEE 1709-2010 | IEEE Recommended Practice for 1 kV to 35 kV Medium-Voltage DC Power Systems on Ships |
| IEEE 1662-2008 | IEEE Guide for the Design and Application of Power Electronics in Electrical Power Systems on Ships |
| ISO 14224:2016 | Petroleum, petrochemical and natural gas industries — Collection and exchange of reliability and maintenance data for equipment |
| IEEE C57.159-2016 | IEEE Guide on Transformers for Application in Distributed Photovoltaic (DPV) Power Generation Systems |
| IEEE 1653.1-2016 | IEEE Standard for Traction Power Rectifier Transformers for Substation Applications up to 1500 V DC Nominal Output |
| IEEE C57.129-2007 REDLINE | IEEE Standard for General Requirements and Test Code for Oil-Immersed HVDC Converter Transformers |
| BS EN ISO 14224:2016 | Petroleum, petrochemical and natural gas industries. Collection and exchange of reliability and maintenance data for equipment |
| IEEE 519-2014 REDLINE | IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems |
| IEEE C57.12.51-2008 | REQUIREMENTS FOR SEALED DRY-TYPE POWER TRANSFORMERS, 501 KVA AND LARGER, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 208Y/120 TO 4160 VOLTS |
| IEEE C57.12.10-2010 | TRANSFORMERS - 230 KV AND BELOW 833/958 THROUGH 8333/10 417 KVA, SINGLE-PHASE, AND 750/862 THROUGH 60 000/80 000/100 000 KVA, THREE-PHASE WITHOUT LOAD TAP CHANGING; AND 3750/4687 THROUGH 60 000/80 000/100 000 KVA WITH LOAD TAP CHANGING - SAFETY REQUIREMENT |
| IEEE C57.12.01-2015 REDLINE | IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers |
| IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
| IEEE C57.91-2011 REDLINE | IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators |
| IEEE C57.96-2013 | IEEE Guide for Loading Dry-Type Distribution and Power Transformers |
| IEEE C57.12.90-2010 | IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers |
| IEEE C57.12.70-2011 | IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers |
| IEEE C57.12.91-2011 | IEEE Standard Test Code for Dry-Type Distribution and Power Transformers |
| IEEE C57.110-2008 REDLINE | IEEE Recommended Practice for Establishing Liquid-Filled and Dry-Type Power and Distribution Transformer Capability When Supplying Nonsinusoidal Load Currents |