IEEE DRAFT 1215 : D13 2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
DRAFT GUIDE FOR THE APPLICATION OF SEPARABLE INSULATED CONNECTORS
22-03-2002
12-01-2013
1 Overview
1.1 Scope
2 References
3 Definitions
4 Design Considerations
4.1 Systems
4.1.1 Underground distribution systems
4.1.2 Single-phase versus three-phase rating
4.1.3 200 A loadbreak versus deadbreak
4.1.4 600 A versus 200 A
4.1.5 Grounding of component shields
4.1.6 Overload rating
4.1.6.1 200 A loadbreak systems
4.1.6.2 200 and 600 A deadbreak
(i.e. non-loadbreak) systems
4.1.7 Interchangeability
4.2 Environmental
4.2.1 Environment
4.2.2 Ultraviolet exposure
4.2.3 Exposure to hydrocarbons
5 Construction/installation
5.1 Use of loadbreak versus deadbreak
5.2 Grounding of components and shields
5.3 Lubrication
5.3.1 Reasons to lubricate
5.3.2 How to lubricate
5.4 Tightening requirements
5.4.1 200 A connectors
5.4.1.1 Bushing insert to bushing
well stud
5.4.1.2 Elbow probe to compression
lug
5.4.2 600 A connectors
5.5 Elbow/bushing assembly
5.6 Compression lugs
5.7 Solvents
5.8 Cleanliness (avoiding contamination)
5.9 Cable training
5.10 Clearance for live-line tool operation
5.11 Operator/bushing location
5.12 Stacking 600 A T's
6 Operation
6.1 Use of loadbreak versus deadbreak
6.2 Deadbreak operating practices
6.2.1 200 A or 600 A deadbreak connector
with a capacitive test point
6.2.2 200 A or 600 A deadbreak connector
without a capacitive test point
6.3 Loadbreak operating practices
6.3.1 Proper operation using live-line tools
6.3.2 Loadbreak switching practices
6.3.3 Loadbreak grounding practices
6.4 Capacitive test point
6.5 Switching
6.5.1 Cable switching
6.5.2 Capacitor switching
6.5.3 Radial and loop switching
6.5.4 Ferroresonance
6.6 Fault duty
6.6.1 Through-faults
6.6.2 Fault close
6.6.3 Use of current limiting fuses
6.6.4 Fault chasing
6.7 Use of accessories
6.7.1 General
6.7.2 Multi-way junctions and feed-thrus
6.7.3 Insulated parking bushings
6.7.4 Deadfront arresters
6.7.4.1 General
6.7.4.2 Elbow arresters
6.7.4.3 Parking bushing arrester
6.7.4.4 Bushing insert arrester
6.7.5 Insulated protective cap
6.7.6 Bushing shipping cap
6.8 Grounding accessories
6.8.1 Test rod
6.8.2 Grounding elbow
6.8.3 Grounded parking bushing
6.9 Inspection of separable connectors
6.9.1 Condition after switching
6.9.2 Elbows
6.9.3 Bushings
Gives general information on the applicaiton and operation of separable connectors. It is meant to be basic and to supplement the manufacturers specific recommendations and established utility practices.
DocumentType |
Draft
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy |
IEEE 386-2016 | IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV |
IEEE 1299/C62.22.1 : 1996 | GUIDE FOR THE CONNECTION OF SURGE ARRESTERS TO PROTECT INSULATED, SHIELDED ELECTRIC POWER CABLE SYSTEMS |
IEEE C2-2017 | NATIONAL ELECTRICAL SAFETY CODE (NESC)(R) |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
IEEE 400-2012 REDLINE | IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.