ISA 12.10.05 : 2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - CLASSIFICATION OF ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS
Hardcopy , PDF
English
31-08-2004
03-12-2013
Foreword
1 Scope
2 References
3 Definitions
4 Area classification for combustible dusts
4.1 General
4.2 Area classification objectives for explosive dust
atmospheres
4.3 Area classification procedure for explosive dust
atmospheres
5 Sources of release for explosive dust atmospheres
5.1 General
5.2 Identification of sources of release
6 Zones for explosive dust atmospheres
6.1 General
6.2 Zones for Dusts
6.3 Examples of zones for explosive dust atmospheres
6.4 Extent of zones for explosive dust atmospheres
7 Dust layer hazard
8 Documentation
8.1 General
8.2 Drawings, data sheets and tables
Annex B (informative) - Risk of Fire from Hot Surface Ignition
of Dust Layer
Annex C (informative) - Housekeeping
Annex D (informative) - United States Major Deviations
This document is concerned with the classification of areas where explosive dust/air mixtures atmospheres and combustible dust layers are present, in order to permit the proper selection of equipment for use in such areas.
| Committee |
SP 12.10
|
| DevelopmentNote |
Renumbered as ISA 61241-10. (05/2006)
|
| DocumentType |
Standard
|
| ISBN |
1-55617-931-6
|
| Pages |
40
|
| PublisherName |
International Society of Automation
|
| Status |
Superseded
|
| SupersededBy |
| NFPA 1 : 2021 | FIRE CODE |
| API 14F : 2008 : R2013 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| API RP 14F:2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| API 14FZ : 2013 | RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS |
| API 14F REDLINE : 2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| NFPA 1 : 2018 | FIRE CODE |
| ISO 4225:1994 | Air quality — General aspects — Vocabulary |
| IEC 61241-0:2004 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
| IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
| IEC 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.