ISA 12.16.01 : 2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - INCREASED SAFETY
25-11-2024
01-01-2002
General Notes
Preface (ISA)
Foreword (UL)
National Differences
Foreword (ISA)
1 Scope
2 References
3 Definitions
4 Constructional requirements for all electrical apparatus
4.1 General
4.2 Terminals for external connections
4.3 Internal connections
4.4 Clearances
4.5 Creepage distances
4.6 Solid electrical insulating materials
4.7 Windings
4.8 Temperature limitations
4.9 Wiring internal to apparatus
4.10 Degrees of protection provided by enclosures
5 Supplementary requirements for specific electrical apparatus
5.1 General
5.2 Rotating electrical machines
5.3 Luminaries designed for mains supply
5.4 Portable lights with their own source of supply for
group II applications
5.5 Measuring instruments and instrument transformers
5.6 Transformers other than instrument transformers
5.7 Batteries
5.8 General purpose connection and junction boxes
5.9 Resistance heaters (other than trace heating)
5.10 Other electrical apparatus
6 Type verifications and type tests
6.1 Dielectric strength
6.2 Rotating electrical machines
6.3 Luminaries designed for mains supply
6.4 Measuring instruments and instrument transformers
6.5 Transformers other than instrument transformers
6.6 Secondary batteries
6.7 General purpose connection and junction boxes
6.8 Resistance heating devices and resistance heating units
6.9 Terminal insulating material tests
6.10 Terminal dielectric tests
7 Routine verifications and routine tests
8 Marking and instructions
8.1 General marking
8.2 Instructions for use
8.3 Installation instructions
Annex A (normative) - Cage motors - Methods of test
and of calculation
Annex B (normative) - Type tests for specific forms of
resistance heating devices or
resistance heating units
Annex C (informative) - Cage motors - Thermal protection
in service
Annex D (informative) - Resistance heating devices and units -
Additional electrical protection
Annex E (informative) - Combinations of terminals and conductors
for general purpose connection and
junction boxes
Annex F (informative) - Dimensions of copper conductors
Annex G (informative) - Bibliography
Annex H (informative) - United States major deviations
Annex I (informative) - Editorial differences between
ANSI/UL 60079-7 and ANSI/ISA-12.16.01-2002
(IEC 60079-7 Mod)
Annex J (informative) - National differences types noted in
ANSI/UL 60079-7
Gives the requirements for the design, construction, testing and marking of electrical apparatus with type of protection increased safety "e" intended for use in Class I, Zone 1, Groups IIA, IIB, and IIC hazardous (classified) locations. Applicable to electrical apparatus with a rated value of supply voltage not exceeding 11 kV r.m.s. a.c. or d.c..
Committee |
SP12
|
DevelopmentNote |
Formerly it was ISA-S12.16.01 (05/2001) Also numbered as UL 60079-7. (09/2003) Renumbered as ISA 60079-7 (09/2005)
|
DocumentType |
Standard
|
PublisherName |
International Society of Automation
|
Status |
Withdrawn
|
ISA 12.13.01 : 2003 | PERFORMANCE REQUIREMENTS FOR COMBUSTIBLE GAS DETECTORS |
ISA 12.02.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONES 0, 1 & 2 HAZARDOUS (CLASSIFIED) LOCATIONS - INTRINSIC SAFETY |
ISA 12.00.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 0, 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS |
API 540 : 1999 : R2006 | ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS |
API 540:1999 | ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS |
ISA 12.26.01 : 1998 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - OIL IMMERSION "O" |
ISA 12.22.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS TYPE OF PROTECTION - FLAMEPROOF "D" |
ISA 12.23.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - ENCAPSULATION "M" |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
ANSI C81.62 : 2017 | ELECTRIC LAMPHOLDERS |
ANSI C78.1 : 91(R1996) | 18W, 24-27W, 36-39W, 40W RAPID-START SINGLE-ENDED FLUORESCENT LAMPS WITH 2G11 BASES |
IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV | Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
IEC 60317-3:2004+AMD1:2010 CSV | Specifications for particular types of winding wires - Part 3: Polyester enamelled round copper wire, class 155 |
IEC 60317-7:1990+AMD1:1997+AMD2:1997 CSV | Specifications for particular types of winding wires - Part 7: Polyimide enamelled round copper wire, class 220 |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
IEC 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) |
IEC 60050-486:1991 | International Electrotechnical Vocabulary (IEV) - Part 486: Secondary cells and batteries |
IEC 60061-2:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders |
ANSI C81.61 : 2017 | ELECTRIC LAMP BASES - SPECIFICATIONS FOR BASES (CAPS) FOR ELECTRIC LAMPS |
IEC 60400:2017 | Lampholders for tubular fluorescent lamps and starterholders |
IEC 60317-8:2010 | Specifications for particular types of winding wires - Part 8: Polyesterimide enamelled round copper wire, class 180 |
IEC 60947-7-1:2009 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV | Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements |
IEC 60044-6:1992 | Instrument transformers - Part 6: Requirements for protective current transformers for transient performance |
IEC 60317-13:2010 | Specifications for particular types of winding wires - Part 13: Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, class 200 |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
IEC 60364-3:1993 | Electrical installations of buildings - Part 3: Assessment of general characteristics |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 62086-1:2001 | Electrical apparatus for explosive gas atmospheres - Electrical resistance trace heating - Part 1: General and testing requirements |
UL 746A:6ED 2012-09-06 | Polymeric Materials - Short Term Property Evaluations |
IEEE 515-2011 | IEEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Industrial Applications |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV | Double-capped fluorescent lamps - Safety specifications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.