ISO 21138-1:2007
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Part 1: Material specifications and performance criteria for pipes, fittings and system
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
22-01-2020
English, French
22-10-2007
ISO 21138-1:2007 specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems in the field of non-pressure underground systems for underground drainage and sewerage.
ISO 21138-1:2007 specifically refers to PVC, PP and PE materials.
ISO 21138-1:2007 covers a range of pipe and fitting sizes, materials, pipe constructions, nominal ring stiffnesses, and gives recommendations concerning colours.
In conjunction with ISO 21138-2 and ISO 21138-3, it is applicable to PVC-U, PP and PE structured-wall pipes and fittings, to their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for the transport of drainage and sewerage.
ISO 21138-1:2007 is applicable to PVC-U, PP and PE structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
For dimensions larger than DN/OD 1200 or DN/ID 1200, ISO 21138-1:2007 can serve as a general guide regarding appearance, colour, physical and mechanical characteristics as well as performance requirements.
DevelopmentNote |
Supersedes ISO/DIS 21138-1. (10/2007)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
NEN ISO 21138-1 : 2008 | Identical |
DIN EN ISO 11296-3:2011-07 | PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 3: LINING WITH CLOSE-FIT PIPES |
ISO 21138-3:2007 | Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Part 3: Pipes and fittings with non-smooth external surface, Type B |
UNI EN ISO 11296-3 : 2011 | PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 3: LINING WITH CLOSE-FIT PIPES |
ISO 15398:2012 | Specifications for thermoplastics covers and frames for manholes and inspection chambers used in non-traffic areas |
EN ISO 11296-3:2011 | Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 3: Lining with close-fit pipes (ISO 11296-3:2009+Cor 1:2011) |
14/30275072 DC : 0 | BS ISO 17902 - WRAPPED ELECTROFOAMING JOINTS FOR PE PIPING SYSTEMS WITH SMOOTH OUTER WALL FOR GRAVITY DRAINS AND SEWERS |
I.S. EN ISO 11296-3:2011 | PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 3: LINING WITH CLOSE-FIT PIPES |
BS EN ISO 11296-3:2011 | Plastics piping systems for renovation of under ground non-pressure drainage and sewerage networks Lining with close-fit pipes |
ISO/TS 17902:2016 | Wrapped electrofoaming joints for polyethylene (PE) piping systems with smooth outer wall for gravity drains and sewers |
UNE-EN ISO 11296-3:2011 | Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 3: Lining with close-fit pipes (ISO 11296-3:2009+Cor 1:2011) |
ISO 11296-3:2009 | Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks Part 3: Lining with close-fit pipes |
08/30174001 DC : DRAFT JUNE 2008 | BS ISO 11296-3 - PLASTICS PIPING SYSTEMS FOR RENOVATION OF UNDERGROUND NON-PRESSURE DRAINAGE AND SEWERAGE NETWORKS - PART 3: LINING WITH CLOSE-FIT PIPES |
BS ISO 15398:2012 | Specifications for thermoplastics covers and frames for manholes and inspection chambers used in non-traffic areas |
ISO 21138-2:2007 | Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Part 2: Pipes and fittings with smooth external surface, Type A |
ISO 13272:2011 | Plastics piping systems for non-pressure underground drainage and sewerage — Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifiers (PP-MD) and polyethylene (PE) — Specifications for manholes and inspection chambers in traffic areas and underground installations |
11/30245512 DC : 0 | BS ISO 15398 - SPECIFICATIONS FOR THERMOPLASTICS COVERS AND FRAMES FOR MANHOLES AND INSPECTION CHAMBERS USED IN NON-TRAFFIC AREAS |
06/30136263 DC : DRAFT MAR 2006 | ISO 21138-2 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYLCHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2 - PIPES AND FITTINGS WITH SMOOTH EXTERNAL SURFACE - TYPE A |
EN 1277:2003 | Plastics piping systems - Thermoplastics piping systems for buried non-pressure applications - Test methods for leaktightness of elastomeric sealing ring type joints |
EN 295-3:2012 | Vitrified clay pipe systems for drains and sewers - Part 3: Test methods |
ISO 580:2005 | Plastics piping and ducting systems — Injection-moulded thermoplastics fittings — Methods for visually assessing the effects of heating |
ISO/TR 10358:1993 | Plastics pipes and fittings Combined chemical-resistance classification table |
ISO 2507-2:1995 | Thermoplastics pipes and fittings — Vicat softening temperature — Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes |
EN 1295-1:1997 | Structural design of buried pipelines under various conditions of loading - Part 1: General requirements |
ISO 12091:1995 | Structured-wall thermoplastics pipes Oven test |
ISO 8773:2006 | Plastics piping systems for non-pressure underground drainage and sewerage Polypropylene (PP) |
ISO 1167-2:2006 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 2: Preparation of pipe test pieces |
ISO 265-1:1988 | Pipes and fittings of plastics materials Fittings for domestic and industrial waste pipes Basic dimensions: Metric series Part 1: Unplasticized poly(vinyl chloride) (PVC-U) |
ISO 8772:2006 | Plastics piping systems for non-pressure underground drainage and sewerage Polyethylene (PE) |
ISO 11173:1994 | Thermoplastics pipes — Determination of resistance to external blows — Staircase method |
ISO 2507-1:1995 | Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method |
ISO 21138-3:2007 | Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Part 3: Pipes and fittings with non-smooth external surface, Type B |
ISO 3127:1994 | Thermoplastics pipes — Determination of resistance to external blows — Round-the-clock method |
ISO/TR 7620:2005 | Rubber materials — Chemical resistance |
ISO 11359-2:1999 | Plastics Thermomechanical analysis (TMA) Part 2: Determination of coefficient of linear thermal expansion and glass transition temperature |
EN 12061:1999 | Plastics piping systems - Thermoplastics fittings - Test method for impact resistance |
ISO 3126:2005 | Plastics piping systems Plastics components Determination of dimensions |
ISO 11922-1:1997 | Thermoplastics pipes for the conveyance of fluids — Dimensions and tolerances — Part 1: Metric series |
ISO 21138-2:2007 | Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Part 2: Pipes and fittings with smooth external surface, Type A |
EN 1979:1999 | Plastics piping and ducting systems - Thermoplastics spirally-formed structured-wall pipes - Determination of the tensile strength of a seam |
ISO 472:2013 | Plastics — Vocabulary |
ISO 1183-1:2012 | Plastics Methods for determining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method and titration method |
EN 14741:2006 | Thermoplastics piping and ducting systems - Joints for buried non-pressure applications - Test method for the long-term sealing performance of joints with elastomeric seals by estimating the sealing pressure |
ISO 11357-6:2008 | Plastics Differential scanning calorimetry (DSC) Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) |
ISO 4435:2003 | Plastics piping systems for non-pressure underground drainage and sewerage Unplasticized poly(vinyl chloride) (PVC-U) |
EN 1610:2015 | Construction and testing of drains and sewers |
ISO 9967:2016 | Thermoplastics pipes Determination of creep ratio |
EN 1053:1995 | Plastics piping systems - Thermoplastics piping systems for non-pressure applications - Test method for watertightness |
ISO 13967:2009 | Thermoplastics fittings Determination of ring stiffness |
ISO 178:2010 | Plastics Determination of flexural properties |
ISO 1043-1:2011 | Plastics — Symbols and abbreviated terms — Part 1: Basic polymers and their special characteristics |
ISO 9969:2016 | Thermoplastics pipes Determination of ring stiffness |
EN 12256:1998 | Plastics piping systems - Thermoplastics fittings - Test method for mechanical strength or flexibility of fabricated fittings |
ISO 1133:2005 | Plastics Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastics |
ISO 9852:2007 | Unplasticized poly(vinyl chloride) (PVC-U) pipes — Dichloromethane resistance at specified temperature (DCMT) — Test method |
ISO 1167-1:2006 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pressure Part 1: General method |
ISO 2505:2005 | Thermoplastics pipes — Longitudinal reversion — Test method and parameters |
EN 1446 : 1996 | PLASTICS PIPING AND DUCTING SYSTEMS - THERMOPLASTICS PIPES - DETERMINATION OF RING FLEXIBILITY |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.