ISO 4064-4:2014 applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume.
ISO 4064-4:2014 specifies technical characteristics and pressure loss requirements for meters for cold potable water and hot water. It applies to water meters which can withstand: a) a maximum admissible working pressure (MAP) equal to at least 1 MPa [0,6 MPa for meters for use with pipe nominal diameters (DNs) ≥500 mm]; b) a maximum admissible temperature (MAT) for cold potable water meters of 30 °C; c) a MAT for hot water meters up to 180 °C, depending on class.
In addition to meters based on mechanical principles, ISO 4064-4:2014 also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to meter the volume flow of hot water and cold potable water. It also applies to electronic ancillary devices. As a rule ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter.
DevelopmentNote |
Supersedes ISO/DIS 4064-4. (05/2014)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Standards | Relationship |
NF EN ISO 4064-4 : 2014 | Identical |
NBN EN ISO 4064-4 : 2014 | Identical |
NEN EN ISO 4064-4 : 2014 | Identical |
NS EN ISO 4064-4 : 2014 | Identical |
I.S. EN ISO 4064-4:2014 | Identical |
PN EN ISO 4064-4 : 2014 | Identical |
SN EN ISO 4064-4 : 2014 | Identical |
UNI CEI EN ISO 4064-4 : 2014 | Identical |
BS EN ISO 4064-4:2014 | Identical |
CEI UNI EN ISO 4064-4 : 2ED MAR 2015 | Identical |
DIN EN ISO 4064-4:2014-11 | Identical |
UNE-EN ISO 4064-4:2015 | Identical |
EN ISO 4064-4:2014 | Identical |
I.S. EN 14154-4:2014 | WATER METERS - PART 4: ADDITIONAL FUNCTIONALITIES |
UNI CEI EN ISO 4064-1 : 2014 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
ONORM EN 14154-4 : 2015 | WATER METERS - PART 4: ADDITIONAL FUNCTIONALITIES |
BS EN 60598-2-21:2015 | Luminaires Particular requirements. Rope lights |
DIN EN 14154-4:2015-02 | Water meters - Part 4: Additional functionalities |
DIN EN ISO 4064-1:2016-09 (Draft) | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS (ISO 4064-1:2014) |
ISO 20456:2017 | Measurement of fluid flow in closed conduits — Guidance for the use of electromagnetic flowmeters for conductive liquids |
BS EN 14154-4:2014 | Water meters Additional functionalities |
11/30217192 DC : 0 | BS EN ISO 4064-2 - WATER METERS INTENDED FOR THE METERING OF COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS |
15/30317327 DC : 0 | BS EN 16941-1 - ON-SITE NON-POTABLE WATER SYSTEMS - PART 1: SYSTEMS FOR THE USE OF RAINWATER |
BS EN ISO 4064-1:2017 | Water meters for cold potable water and hot water Metrological and technical requirements |
UNE-EN ISO 4064-1:2015 | Water meters for cold potable water and hot water - Part 1: Metrological and technical requirements (ISO 4064-1:2014) |
ISO 4064-1:2014 | Water meters for cold potable water and hot water Part 1: Metrological and technical requirements |
UNE-EN 60598-2-21:2015 | Luminaires - Part 2-21: Particular requirements - Rope lights |
EN ISO 4064-1:2017 | Water meters for cold potable water and hot water - Part 1: Metrological and technical requirements (ISO 4064-1:2014) |
EN 14154-4:2014 | Water meters - Part 4: Additional functionalities |
UNE-EN 14154-4:2015 | Water meters - Part 4: Additional functionalities |
I.S. EN ISO 4064-1:2017 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS (ISO 4064-1:2014) |
UNI EN 14154-4 : 2015 | WATER METERS - PART 4: ADDITIONAL FUNCTIONALITIES |
EN 60598-2-21:2015/AC:2017-01 | LUMINAIRES - PART 2-21: PARTICULAR REQUIREMENTS - ROPE LIGHTS (IEC 60598-2-21:2014/COR1:2016) |
DIN EN ISO 4064-1:2017-10 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS (ISO 4064-1:2014) |
ISO 7005-2:1988 | Metallic flanges — Part 2: Cast iron flanges |
OIML D 11 : 2013 | GENERAL REQUIREMENTS FOR MEASURING INSTRUMENTS - ENVIRONMENTAL CONDITIONS |
ISO 7005-3:1988 | Metallic flanges Part 3: Copper alloy and composite flanges |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
OIML R 49-1 : 2013 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
ISO 4064-1:2014 | Water meters for cold potable water and hot water Part 1: Metrological and technical requirements |
OIML V 1 : 2013 | INTERNATIONAL VOCABULARY OF TERMS IN LEGAL METROLOGY (VIML) |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.