ISO 5356-1:2015
Current
The latest, up-to-date edition.
Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, French
13-03-2015
ISO 5356-1:2015 specifies dimensional and gauging requirements for cones and sockets intended for connecting anaesthetic and respiratory equipment, e.g. in breathing systems, anaesthetic gas scavenging systems, and vaporizers. The cones and sockets are therefore not regarded as devices in their own right.
It gives requirements for the following cones and sockets: 8,5 mm and 11,5 mm sizes intended for use in neonatal and paediatric breathing systems; 15 mm and 22 mm sizes intended for general use in breathing systems; 22 mm latching sockets (including performance requirements); 23 mm size intended for use with vaporizers, but not for use in breathing systems; 30 mm size intended for the connection of a breathing system to an anaesthetic gas scavenging system.
It does not specify the medical devices and accessories on which these cones and sockets are to be provided.
Requirements for the application of cones and sockets are not included, but are or will be given in the relevant International Standards for specific medical devices and accessories. Requirements for screw-threaded weight-bearing connectors are specified in ISO 5356 2.
DevelopmentNote |
Supersedes ASTM F 1054 (01/2006) Supersedes ISO/DIS 5356-1. (03/2015)
|
DocumentType |
Standard
|
Pages |
17
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
JIS T 7201-2-1:2017 | Identical |
CSA ISO 5356-1:15 (R2020) | Identical |
NF EN ISO 5356-1 : 2015 | Identical |
NBN EN ISO 5356-1 : 2015 | Identical |
NEN EN ISO 5356-1 : 2015 | Identical |
UNE-EN ISO 5356-1:2015 | Identical |
NS EN ISO 5356-1 : 2015 | Identical |
I.S. EN ISO 5356-1:2015 | Identical |
PN EN ISO 5356-1 : 2015 | Identical |
SN EN ISO 5356-1 : 2016 | Identical |
UNI EN ISO 5356-1 : 2004 | Identical |
SS-EN ISO 5356-1:2015 | Identical |
UNI EN ISO 5356-1:2015 | Identical |
BS EN ISO 5356-1:2015 | Identical |
EN ISO 5356-1:2015 | Identical |
CSA ISO 5356-1 : 2015 | Identical |
DIN EN ISO 5356-1:2015-06 | Identical |
BIS IS/ISO 5356-1 : 2004(R2017) | Identical |
AAMI ISO 5356-1 : 2004 | Identical |
BS ISO 16571:2014 | Systems for evacuation of plume generated by medical devices |
I.S. EN ISO 80369-1:2010 | SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 1: GENERAL REQUIREMENTS |
CSA Z8835.3 : 2008 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 3: TRANSFER AND RECEIVING SYSTEMS OF ACTIVE ANAESTHETIC GAS SCAVENGING SYSTEMS |
DD ISO/TS 18835:2004 | Inhalational anaesthesia systems. Draw-over vaporizers and associated equipment |
I.S. EN ISO 8835-4:2009 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 4: ANAESTHETIC VAPOUR DELIVERY DEVICES |
AAMI ISO 80369-1 : 2010 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 1: GENERAL REQUIREMENTS |
BS EN ISO 23328-2:2009 | Breathing system filters for anaesthetic and respiratory use Non-filtration aspects |
UNE-EN ISO 80369-7:2017 | Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications (ISO 80369-7:2016, Corrected version 2016-12-01) |
CSA Z8185 : 2008 | RESPIRATORY TRACT HUMIDIFIERS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR RESPIRATORY HUMIDIFICATION SYSTEMS |
01/560793 DC : DRAFT FEB 2001 | IEC/DIS 60601-2-13 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-13: PARTICULAR REQUIREMENTS FOR THE SAFETY OF ANAESTHETIC SYSTEMS |
13/30268585 DC : 0 | BS EN ISO 10079-1 - MEDICAL SUCTION EQUIPMENT - PART 1: ELECTRICALLY POWERED SUCTION EQUIPMENT |
09/30203808 DC : 0 | BS EN ISO 80601-2-12 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
ONORM EN ISO 5356-2 : 2013 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - CONICAL CONNECTORS - PART 2: SCREW-THREADED WEIGHT-BEARING CONNECTORS (ISO 5356-2:2012) |
DIN EN ISO 8835-3:2011-02 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 3: TRANSFER AND RECEIVING SYSTEMS OF ACTIVE ANAESTHETIC GAS SCAVENGING SYSTEMS |
13/30242951 DC : 0 | BS ISO 16571 - MEDICAL GAS SYSTEMS - SYSTEMS FOR EVACUATION OF PLUME GENERATED BY MEDICAL DEVICES |
UNI EN 13976-2 : 2011 | RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS |
03/103294 DC : DRAFT JAN 2003 | BS EN ISO 10651-6 - LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 6: HOME CARE VENTILATORY SUPPORT DEVICES |
BS EN 60601-2-13:2006 | Medical electrical equipment Particular requirements for the safety and essential performance of anaesthetic systems |
I.S. EN 60601-2-12:2006 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR THE SAFETY OF LUNG VENTILATORS - CRITICAL CARE VENTILATORS |
BS 7259-1(1993) : AMD 9350 | NON ELECTRICAL MEDICAL SUCTION EQUIPMENT - SPECIFICATION FOR MANUALLY POWERED SUCTION EQUIPMENT |
BS 5724-2.30(1993) : 1993 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR CAPNOMETERS FOR USE WITH HUMANS |
CSA Z10651.6 : 2006 : R2015 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 6: HOME-CARE VENTILATORY SUPPORT DEVICES |
CAN/CSA-C22.2 NO. 80601-2-72:17 | Medical electrical equipment — Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients (Adopted ISO 80601-2-72:2015, first edition, 2015-09-01, with Canadian deviations) |
BIS IS/ISO 10079-3 : 1999 | MEDICAL SUCTION EQUIPMENT - PART 3: SUCTION EQUIPMENT POWERED FROM A VACUUM OR PRESSURE SOURCE |
CSA Z8185 : 2008(R2013) | RESPIRATORY TRACT HUMIDIFIERS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR RESPIRATORY HUMIDIFICATION SYSTEMS |
BS EN ISO 10079-1:2015 | Medical suction equipment Electrically powered suction equipment |
04/30088362 DC : DRAFT NOV 2004 | ISO 10651-5 - LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 5: GAS-POWERED EMERGENCY VENTILATORS |
CSA Z10079.1 : 2003 : R2013 | MEDICAL SUCTION EQUIPMENT - PART 1: ELECTRICALLY POWERED SUCTION EQUIPMENT - SAFETY REQUIREMENTS |
CSA Z17510.1 : 2010 | SLEEP APNOEA BREATHING THERAPY - PART 1: SLEEP APNOEA BREATHING THERAPY EQUIPMENT |
ISO 7228:1993 | Tracheal tube connectors |
BS EN ISO 80601-2-12:2011 | Medical electrical equipment Particular requirements for basic safety and essential performance of critical care ventilators |
AMEDP-1.15 : 2016 | COMPATIBILITY OF MEDICAL TUBING AND CONNECTORS IN THE FIELD |
UNI CEI EN ISO 80369-1 : 2011 | SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 1: GENERAL REQUIREMENTS |
ISO 80601-2-70:2015 | Medical electrical equipment Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipment |
I.S. EN ISO 10079-1:2015 | MEDICAL SUCTION EQUIPMENT - PART 1: ELECTRICALLY POWERED SUCTION EQUIPMENT (ISO 10079-1:2015) |
CSA ISO 5362 : 2014 | ANAESTHETIC RESERVOIR BAGS |
ISO 80601-2-74:2017 | Medical electrical equipment Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipment |
AAMI CN6 : 2015 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 6: CONNECTORS FOR NEURAXIAL APPLICATIONS |
UNE-EN ISO 80369-6:2016 | Small bore connectors for liquids and gases in healthcare applications - Part 6: Connectors for neuraxial applications (ISO 80369-6:2016, Corrected version 2016-11-15) |
ASTM F 920 : 1993 : R1999 | Standard Specification for Minimum Performance and Safety Requirements for Resuscitators Intended for Use With Humans (Withdrawn 2007) |
BS EN ISO 80601-2-13:2012+A2:2019 | Medical electrical equipment Particular requirements for basic safety and essential performance of an anaesthetic workstation |
EN 13718-2:2015 | Medical vehicles and their equipment - Air ambulances - Part 2: Operational and technical requirements for air ambulances |
ISO 8835-5:2004 | Inhalational anaesthesia systems Part 5: Anaesthetic ventilators |
ISO 80369-3:2016 | Small-bore connectors for liquids and gases in healthcare applications — Part 3: Connectors for enteral applications |
DIN EN ISO 23328-2:2009-07 | BREATHING SYSTEM FILTERS FOR ANAESTHETIC AND RESPIRATORY USE - PART 2: NON-FILTRATION ASPECTS |
EN ISO 23328-2:2009 | Breathing system filters for anaesthetic and respiratory use - Part 2: Non-filtration aspects (ISO 23328-2:2002) |
EN 1282-2:2005+A1:2009 | Tracheostomy tubes - Part 2: Paediatric tubes (ISO 5366-3:2001, modified) |
EN ISO 5366:2016 | Anaesthetic and respiratory equipment - Tracheostomy tubes and connectors (ISO 5366:2016) |
EN 1281-2 : 1995 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - CONICAL CONNECTORS - SCREW-THREADED WEIGHT-BEARING CONNECTORS |
BS 6149-2:1993 | Tracheostomy tubes Basic requirements for tubes for adults |
EN ISO 80601-2-13:2012 | Medical electrical equipment - Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation (ISO 80601-2-13:2011) |
BS 6149-1:1987 | Tracheostomy tubes Specification for connectors |
EN ISO 5366-1:2009 | Anaesthetic and respiratory equipment - Tracheostomy tubes - Part 1: Tubes and connectors for use in adults (ISO 5366-1:2000) |
EN 13544-1:2007+A1:2009 | Respiratory therapy equipment - Part 1: Nebulizing systems and their components |
CAN/CSA-ISO 16571:16 | SYSTEMS FOR EVACUATION OF PLUME GENERATED BY MEDICAL DEVICES |
BS EN ISO 80601-2-13:2012 | Medical electrical equipment Particular requirements for basic safety and essential performance of an anaesthetic workstation |
CSA Z168.5.1 : 1997 | ANAESTHESIA VENTILATORS |
UNE-EN ISO 80369-1:2011 | Small bore connectors for liquids and gases in healthcare applications - Part 1: General requirements (ISO 80369-1:2010) |
17/30338753 DC : 0 | BS ISO 80601-2-79 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-79: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF VENTILATORY SUPPORT EQUIPMENT FOR VENTILATORY IMPAIRMENT |
09/30173644 DC : 0 | BS EN ISO 80369-1 - SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 1: GENERAL REQUIREMENTS |
BS EN ISO 80601-2-72:2015 | Medical electrical equipment Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients |
BS EN ISO 8836:2014 | Suction catheters for use in the respiratory tract |
BS ISO 8600-2:2015 | Endoscopes. Medical endoscopes and endotherapy devices Particular requirements for rigid bronchoscopes |
UNI EN ISO 5367 : 2015 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - BREATHING SETS AND CONNECTORS |
I.S. EN ISO 80369-6:2016 | SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 6: CONNECTORS FOR NEURAXIAL APPLICATIONS (ISO/IEC/DIS 80369-6:2014) |
ISO 80369-6:2016 | Small bore connectors for liquids and gases in healthcare applications — Part 6: Connectors for neuraxial applications |
BS ISO 10651-5:2006 | Lung ventilators for medical use. Particular requirements for basic safety and essential performance Gas-powered emergency resuscitators |
AAMI ISO 5361 : 2012 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEAL TUBES AND CONNECTORS |
DIN EN ISO 80601-2-72:2016-04 | Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients (ISO 80601-2-72:2015) |
EN ISO 80369-6 : 2016 COR 2016 | SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 6: CONNECTORS FOR NEURAXIAL APPLICATIONS (ISO 80369-6:2016, CORRECTED VERSION 2016-11-15) |
BS EN 60601-2-12:2006 | Medical electrical equipment Particular requirements for the safety of lung ventilators. Critical care ventilators |
15/30288418 DC : 0 | BS EN ISO 80369-2 - SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 2: CONNECTORS FOR BREATHING SYSTEMS AND DRIVING GASES APPLICATIONS |
BS EN ISO 80369-1:2010 | Small bore connectors for liquids and gases in healthcare applications General requirements |
UNI EN ISO 80601-2-12 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
12/30266576 DC : 0 | BS EN 13718-2 - MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS OF AIR AMBULANCES |
CSA Z7228 : 0 | TRACHEAL TUBE CONNECTORS |
CSA ISO 11712 : 2014 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - SUPRALARYNGEAL AIRWAYS AND CONNECTORS |
CEI EN 80369-5 : 1ED 2017 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS |
DIN EN ISO 8836:2015-02 | Suction catheters for use in the respiratory tract (ISO 8836:2014); German version EN ISO 8836:2014 |
BS EN ISO 80369-3:2016 | Small-bore connectors for liquids and gases in healthcare applications Connectors for enteral applications |
CSA Z8836 :2011 | SUCTION CATHETERS FOR USE IN THE RESPIRATORY TRACT |
CSA Z8836 : 2011 : R2015 | SUCTION CATHETERS FOR USE IN THE RESPIRATORY TRACT |
ISO 8600-2:2015 | Endoscopes - Medical endoscopes and endotherapy devices Part 2: Particular requirements for rigid bronchoscopes |
I.S. EN ISO 5361:2016 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEAL TUBES AND CONNECTORS (ISO/DIS 5361:2014) |
ISO 11712:2009 | Anaesthetic and respiratory equipment — Supralaryngeal airways and connectors |
UNE-EN 13976-2:2011 | Rescue systems - Transportation of incubators - Part 2: System requirements |
AAMI ISO 10079-1 : 1999 | MEDICAL SUCTION EQUIPMENT - PART 1: ELECTRICALLY POWERED SUCTION EQUIPMENT - SAFETY REQUIREMENTS |
CSA Z15883-5:2009 | WASHER-DISINFECTORS - PART 5: TEST SOILS AND METHODS FOR DEMONSTRATING CLEANING EFFICACY |
I.S. EN 60601-2-13:2006 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-13: PARTICULAR REQUIREMENTS FOR THE SAFETY AND ESSENTIAL PERFORMANCE OF ANAESTHETIC SYSTEMS |
AAMI ISO 5367 : 2015 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - BREATHING SETS AND CONNECTORS |
CSA ISO 10079-3:14 (R2019) | Medical suction equipment - Part 3: Suction equipment powered from a vacuum or positive pressure gas source (Adopted ISO 10079-3:2014, third edition, 2014-05-01) |
I.S. ISO 5369:1987 | BREATHING MACHINES FOR MEDICAL USE - LUNG VENTILATORS |
AAMI ISO 8836 : 2015 | SUCTION CATHETERS FOR USE IN THE RESPIRATORY TRACT |
I.S. EN ISO 80369-3:2016 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 3: CONNECTORS FOR ENTERAL APPLICATIONS (ISO/IEC/DIS 80369-3:2014) |
ISO 17510:2015 | Medical devices — Sleep apnoea breathing therapy — Masks and application accessories |
UNI EN ISO 23328-2 : 2009 | BREATHING SYSTEM FILTERS FOR ANAESTHETIC AND RESPIRATORY USE - PART 2: NON-FILTRATION ASPECTS |
CEI UNI EN ISO 80369-1 : 2011 | SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 1: GENERAL REQUIREMENTS |
CSA ISO 11712:14 (R2019) | Anaesthetic and respiratory equipment - Supralaryngeal airways and connectors (Adopted ISO 11712:2009, first edition, 2009-05-15) |
NF EN 60601 2-13 : 2007 AMD 1 2007 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-13: PARTICULAR REQUIREMENTS FOR THE SAFETY AND ESSENTIAL PERFORMANCE OF ANAESTHETIC SYSTEMS |
CSA ISO 10079-2 : 2014 | MEDICAL SUCTION EQUIPMENT - PART 2: MANUALLY POWERED SUCTION EQUIPMENT |
CSA Z17510.2 : 2009 | SLEEP APNOEA BREATHING THERAPY - PART 2: MASKS AND APPLICATION ACCESSORIES |
BS EN ISO 5367:2014 | Anaesthetic and respiratory equipment. Breathing sets and connectors |
UNE-EN ISO 5367:2015 | Anaesthetic and respiratory equipment - Breathing sets and connectors (ISO 5367:2014) |
BS EN ISO 80369-6:2016 | Small bore connectors for liquids and gases in healthcare applications Connectors for neuraxial applications |
EN ISO 5356-2:2012 | Anaesthetic and respiratory equipment - Conical connectors - Part 2: Screw-threaded weight-bearing connectors (ISO 5356-2:2012) |
ISO 8836:2014 | Suction catheters for use in the respiratory tract |
ISO 5367:2014 | Anaesthetic and respiratory equipment — Breathing sets and connectors |
DIN EN ISO 8835-4:2009-07 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 4: ANAESTHETIC VAPOUR DELIVERY DEVICES |
DIN EN ISO 17510-2:2009-07 | SLEEP APNOEA BREATHING THERAPY - PART 2: MASKS AND APPLICATION ACCESSORIES |
DIN EN ISO 8835-2:2009-08 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 2: ANAESTHETIC BREATHING SYSTEMS |
DIN EN ISO 5356-2:2013-03 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - CONICAL CONNECTORS - PART 2: SCREW-THREADED WEIGHT-BEARING CONNECTORS (ISO 5356-2:2012) |
DIN EN ISO 17510-1:2009-07 | Sleep apnoea breathing therapy - Part 1: Sleep apnoea breathing therapy equipment (ISO 17510-1:2007) |
UNE-EN ISO 80601-2-13:2013 | Medical electrical equipment - Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation (ISO 80601-2-13:2011) |
BS EN ISO 10079-2:2014 | Medical suction equipment Manually powered suction equipment |
BS EN ISO 8835-2:2009 | Inhalational anaesthesia systems Anaesthetic breathing systems (ISO 8835-2:2007) |
BS EN ISO 9360-1:2009 | Anaesthetic and respiratory equipment. Heat and moisture exchangers (HMEs) for humidifying respired gases in humans HMEs for use with minimal tidal volumes of 250 ml |
I.S. EN ISO 1119:2011 | GEOMETRICAL PRODUCT SPECIFICATIONS (GPS) - SERIES OF CONICAL TAPERS AND TAPER ANGLES (ISO 1119:2011) |
I.S. EN ISO 5366-1:2009 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEOSTOMY TUBES - PART 1: TUBES AND CONNECTORS FOR USE IN ADULTS |
I.S. EN ISO 17510-1:2009 | SLEEP APNOEA BREATHING THERAPY - PART 1: SLEEP APNOEA BREATHING THERAPY EQUIPMENT |
EN ISO 17510-1:2009 | Sleep apnoea breathing therapy - Part 1: Sleep apnoea breathing therapy equipment (ISO 17510-1:2007) |
ONORM EN ISO 8836 : 2015 | SUCTION CATHETERS FOR USE IN THE RESPIRATORY TRACT (ISO 8836:2014) |
I.S. EN ISO 10079-2:2014 | MEDICAL SUCTION EQUIPMENT - PART 2: MANUALLY POWERED SUCTION EQUIPMENT (ISO 10079-2:2014) |
I.S. EN ISO 17510-2:2009 | SLEEP APNOEA BREATHING THERAPY - PART 2: MASKS AND APPLICATION ACCESSORIES |
DIN EN 1820:2009-12 | ANAESTHETIC RESERVOIR BAGS |
I.S. EN ISO 8185:2009 | RESPIRATORY TRACT HUMIDIFIERS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR RESPIRATORY HUMIDIFICATION SYSTEMS |
DIN EN ISO 5366:2017-04 | Anaesthetic and respiratory equipment - Tracheostomy tubes and connectors (ISO 5366:2016); German version EN ISO 5366:2016 |
I.S. EN ISO 9360-1:2009 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - HEAT AND MOISTURE EXCHANGERS (HMES) FOR HUMIDIFYING RESPIRED GASES IN HUMANS - PART 1: HMES FOR USE WITH MINIMUM TIDAL VOLUMES OF 250 ML |
I.S. EN ISO 9360-2:2009 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - HEAT AND MOISTURE EXCHANGERS (HMES) FOR HUMIDIFYING RESPIRED GASES IN HUMANS - PART 2: HMES FOR USE WITH TRACHEOSTOMIZED PATIENTS HAVING MINIMUM TIDAL VOLUMES OF 250 ML |
DIN EN ISO 10651-2:2011-06 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 2: HOME CARE VENTILATORS FOR VENTILATOR-DEPENDENT PATIENTS |
I.S. EN 1282-2:2005 | TRACHEOSTOMY TUBES - PART 2: PAEDIATRIC TUBES |
I.S. EN ISO 10079-3:2014 | MEDICAL SUCTION EQUIPMENT - PART 3: SUCTION EQUIPMENT POWERED FROM A VACUUM OR POSITIVE PRESSURE GAS SOURCE (ISO 10079-3:2014) |
DIN EN ISO 5366-1:2009-07 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEOSTOMY TUBES - PART 1: TUBES AND CONNECTORS FOR USE IN ADULTS |
BS 3353:1987 | Specification for anaesthetic reservoir bags |
BS 6546:1994 | Specification for tracheal tube connectors |
DIN EN ISO 5366:2015-10 (Draft) | ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEOSTOMY TUBES AND CONNECTORS (ISO 5366:2016) |
NF EN ISO 8835-3 : 2009 AMD 1 2011 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 3: TRANSFER AND RECEIVING SYSTEMS OF ACTIVE ANAESTHETIC GAS SCAVENGING SYSTEMS |
15/30300279 DC : 0 | BS ISO 80601-2-74 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-74: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY HUMIDIFYING EQUIPMENT |
16/30333925 DC : 0 | BS EN 13976-2 - RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS |
I.S. EN ISO 8835-2:2009 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 2: ANAESTHETIC BREATHING SYSTEMS |
BS EN ISO 80369-7:2017 | Small-bore connectors for liquids and gases in healthcare applications Connectors for intravascular or hypodermic applications |
14/30297400 DC : 0 | BS ISO 8600-2 - OPTICS AND OPTICAL INSTRUMENTS - MEDICAL ENDOSCOPES AND ENDOSCOPIC ACCESSORIES - PART 2: PARTICULAR REQUIREMENTS FOR RIGID BRONCHOSCOPES |
ISO 5356-2:2012 | Anaesthetic and respiratory equipment — Conical connectors — Part 2: Screw-threaded weight-bearing connectors |
AAMI ISO 10651-5 : 2006 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 5: GAS-POWERED EMERGENCY RESUSCITATORS |
ISO 16571:2014 | Systems for evacuation of plume generated by medical devices |
UNE-EN ISO 10079-1:2016 | Medical suction equipment - Part 1: Electrically powered suction equipment (ISO 10079-1:2015) |
04/30088533 DC : DRAFT MARCH 2004 | BS EN ISO 8185 - RESPIRATORY TRACT HUMIDIFIERS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR RESPIRATORY HUMIDIFICATION SYSTEMS |
ISO 9918:1993 | Capnometers for use with humans Requirements |
AAMI ISO 10079-3 : 1999 | MEDICAL SUCTION EQUIPMENT - PART 3: SUCTION EQUIPMENT POWERED FROM A VACUUM OR PRESSURE SOURCE |
16/30346835 DC : 0 | BS ISO 20789 - ANAESTHETIC AND RESPIRATORY EQUIPMENT - PASSIVE HUMIDIFIERS |
CSA Z10079.3 : 2003 : R2013 | MEDICAL SUCTION EQUIPMENT - PART 3: SUCTION EQUIPMENT POWERED FROM A VACUUM OR PRESSURE SOURCE |
04/30099768 DC : DRAFT DEC 2004 | PREN ISO 8835-3 - INHALATIONAL ANAESTHESIA SYSTEMS - PART 3: ANAESTHETIC GAS SCAVENGING SYSTEMS - TRANSFER AND RECEIVING SYSTEMS |
CSA Z8836 : 2011 : FR | SUCTION CATHETERS FOR USE IN THE RESPIRATORY TRACT |
UNI EN ISO 8836 : 2015 | A SUCTION CATHETERS FOR USE IN THE RESPIRATORY TRACT |
ISO 5366-2:1993 | Tracheostomy tubes — Part 2: Basic requirements for tubes for adults |
UNE-EN ISO 8836:2015 | Suction catheters for use in the respiratory tract (ISO 8836:2014) |
CSA Z10651.6 : 2006 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 6: HOME-CARE VENTILATORY SUPPORT DEVICES |
UNE-EN 80369-5:2017 | Small-bore connectors for liquids and gases in healthcare applications - Part 5: Connectors for limb cuff inflation applications |
I.S. EN ISO 80601-2-12:2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS (ISO 80601-2-12:2011/COR 1:2011) |
I.S. EN 80369-5:2016 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS |
CEI EN 60601-2-12 : 2007 | MEDICAL ELECTRICAL EQUIPMENT - PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY OF LUNG VENTILATORS - CRITICAL CARE VENTILATORS |
I.S. CEN ISO TS 15883-5:2006 | WASHER-DISINFECTORS - PART 5: TEST SOILS AND METHODS FOR DEMONSTRATING CLEANING EFFICACY |
ANSI/AAMI/ISO 80369-7:2016 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 7: CONNECTORS FOR INTRAVASCULAR OR HYPODERMIC APPLICATIONS |
CSA Z8382 : 1994 | RESUSCITATORS INTENDED FOR USE WITH HUMANS |
UNI EN ISO 5361 : 2013 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEAL TUBES AND CONNECTORS |
I.S. EN ISO 23328-2:2009 | BREATHING SYSTEM FILTERS FOR ANAESTHETIC AND RESPIRATORY USE - PART 2: NON-FILTRATION ASPECTS |
DIN EN 13976-2:2016-03 (Draft) | RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS |
CSA Z7396.2 : 2002 | MEDICAL GAS PIPELINE SYSTEMS - PART 2: ANAESTHETIC GAS SCAVENGING DISPOSAL SYSTEMS |
CSA ISO 10079-3 : 2014 | MEDICAL SUCTION EQUIPMENT - PART 3: SUCTION EQUIPMENT POWERED FROM A VACUUM OR POSITIVE PRESSURE GAS SOURCE |
CEN ISO/TS 15883-5:2005 | Washer-disinfectors - Part 5: Test soils and methods for demonstrating cleaning efficacy (ISO/TS 15883-5:2005) |
I.S. EN ISO 80601-2-13:2012 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-13: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AN ANAESTHETIC WORKSTATION (ISO 80601-2-13:2011) |
AAMI ISO 5362 : 2006 | ANAESTHETIC RESERVOIR BAGS |
CSA Z8835.2 : 2008 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 2: ANAESTHETIC BREATHING SYSTEMS FOR ADULTS |
EN ISO 80369-1:2010 | Small bore connectors for liquids and gases in healthcare applications - Part 1: General requirements (ISO 80369-1:2010) |
I.S. EN ISO 8836:2014 | SUCTION CATHETERS FOR USE IN THE RESPIRATORY TRACT (ISO 8836:2014) |
DIN EN ISO 10651-6:2011-06 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 6: HOME-CARE VENTILATORY SUPPORT DEVICES |
DIN EN 13544-1:2009-12 | RESPIRATORY THERAPY EQUIPMENT - PART 1: NEBULIZING SYSTEMS AND THEIR COMPONENTS |
DIN EN 13718-2:2015-05 | MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS FOR AIR AMBULANCES |
DIN EN ISO 10079-3:2014-09 | Medical suction equipment - Part 3: Suction equipment powered from a vacuum or positive pressure gas source (ISO 10079-3:2014) |
ISO 8835-2:2007 | Inhalational anaesthesia systems Part 2: Anaesthetic breathing systems |
ISO 8835-3:2007 | Inhalational anaesthesia systems Part 3: Transfer and receiving systems of active anaesthetic gas scavenging systems |
ISO 9360-2:2001 | Anaesthetic and respiratory equipment — Heat and moisture exchangers (HMEs) for humidifying respired gases in humans — Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250 ml |
BS EN ISO 11196:1997 | Anaesthetic gas monitors |
UNE-EN 13718-2:2015 | Medical vehicles and their equipment - Air ambulances - Part 2: Operational and technical requirements for air ambulances |
BS EN 13976-2:2011 | Rescue systems. Transportation of incubators System requirements |
ISO 10651-2:2004 | Lung ventilators for medical use Particular requirements for basic safety and essential performance Part 2: Home care ventilators for ventilator-dependent patients |
UNE-EN 1282-2:2006 | Tracheostomy tubes - Part 2: Paediatric tubes (ISO 5366-3:2001, modified) |
I.S. EN 13544-1:2007 | RESPIRATORY THERAPY EQUIPMENT - PART 1: NEBULIZING SYSTEMS AND THEIR COMPONENTS |
EN ISO 8836:2014 | Suction catheters for use in the respiratory tract (ISO 8836:2014) |
I.S. EN 1820:2005 | ANAESTHETIC RESERVOIR BAGS |
ONORM EN 13718-2 : 2015 | MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS FOR AIR AMBULANCES |
UNE-EN ISO 5356-2:2013 | Anaesthetic and respiratory equipment - Conical connectors - Part 2: Screw-threaded weight-bearing connectors (ISO 5356-2:2012) |
EN ISO 9360-2:2009 | Anaesthetic and respiratory equipment - Heat and moisture exchangers (HMEs) for humidifying respired gases in humans - Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250 ml (ISO 9360-2:2001) |
EN ISO 8185:2009 | Respiratory tract humidifiers for medical use - Particular requirements for respiratory humidification systems (ISO 8185:2007) |
UNI EN ISO 1119 : 2012 | GEOMETRICAL PRODUCT SPECIFICATIONS (GPS) - SERIES OF CONICAL TAPERS AND TAPERS ANGLES |
CSA Z8835.4 : 2006 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 4: ANAESTHETIC VAPOUR DELIVERY DEVICES |
UNI EN ISO 10651-2 : 2009 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 2: HOME CARE VENTILATORS FOR VENTILATOR- DEPENDENT PATIENTS |
UNI EN ISO 8835-5 : 2009 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 5: ANAESTHETIC VENTILATORS |
UNI EN ISO 17510-2 : 2009 | SLEEP APNOEA BREATHING THERAPY - PART 2: MASKS AND APPLICATION ACCESSORIES |
UNI EN ISO 10079-3 : 2014 | MEDICAL SUCTION EQUIPMENT - PART 3: SUCTION EQUIPMENT POWERED FROM A VACUUM OR POSITIVE PRESSURE GAS SOURCE |
UNI EN ISO 5366-1 : 2009 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEOSTOMY TUBES - PART 1: TUBES AND CONNECTORS FOR USE IN ADULTS |
UNI EN ISO 9360-1 : 2009 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - HEAT AND MOISTURE EXCHANGERS (HMES) FOR HUMIDIFYING RESPIRED GASES IN HUMANS - PART 1: HMES FOR USE WITH MINIMUM TIDAL VOLUMES OF 250 ML |
ONORM EN ISO 10079-2 : 2014 | MEDICAL SUCTION EQUIPMENT - PART 2: MANUALLY POWERED SUCTION EQUIPMENT (ISO 10079-2:2014) |
UNI EN 1282-2 : 2009 | TRACHEOSTOMY TUBES - PART 2: PAEDIATRIC TUBES |
UNI EN ISO 10079-2 : 2014 | MEDICAL SUCTION EQUIPMENT - PART 2: MANUALLY POWERED SUCTION EQUIPMENT |
UNI EN 13544-1 : 2009 | RESPIRATORY THERAPY EQUIPMENT - PART 1: NEBULIZING SYSTEMS AND THEIR COMPONENTS |
UNI EN ISO 10651-6 : 2009 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 6: HOME-CARE VENTILATORY SUPPORT DEVICES |
ONORM EN ISO 10079-3 : 2014 | MEDICAL SUCTION EQUIPMENT - PART 3: SUCTION EQUIPMENT POWERED FROM A VACUUM OR POSITIVE PRESSURE GAS SOURCE (ISO 10079-3:2014) |
UNI EN ISO 9360-2 : 2009 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - HEAT AND MOISTURE EXCHANGERS (HMES) FOR HUMIDIFYING RESPIRED GASES IN HUMANS - PART 2: HMES FOR USE WITH TRACHEOSTOMIZED PATIENTS HAVING MINIMUM TIDAL VOLUMES OF 250 ML |
UNI EN 1820 : 2009 | ANAESTHETIC RESERVOIR BAGS |
UNI EN ISO 8185 : 2009 | RESPIRATORY TRACT HUMIDIFIERS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR RESPIRATORY HUMIDIFICATION SYSTEMS |
UNI EN ISO 8835-4 : 2009 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 4: ANAESTHETIC VAPOUR DELIVERY DEVICES |
UNE-EN ISO 5361:2017 | Anaesthetic and respiratory equipment - Tracheal tubes and connectors (ISO 5361:2016) |
ISO 7767:1997 | Oxygen monitors for monitoring patient breathing mixtures — Safety requirements |
17/30338756 DC : 0 | BS ISO 80601-2-80 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-80: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF VENTILATORY SUPPORT EQUIPMENT FOR VENTILATORY INSUFFICIENCY |
PREN 13976-2 : DRAFT 2016 | RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS |
BS ISO 18835:2015 | Inhalational anaesthesia systems. Draw-over anaesthetic systems |
UNI EN ISO 8835-2 : 2009 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 2: ANAESTHETIC BREATHING SYSTEMS |
ANSI/AAMI/ISO 80369-3:2016 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 3: CONNECTORS FOR ENTERAL APPLICATIONS |
13/30264413 DC : 0 | BS EN ISO 80601-2-72 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-72: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HOME HEALTHCARE ENVIRONMENT VENTILATORS FOR VENTILATOR-DEPENDENT PATIENTS |
CSA Z15883-5:09 (R2019) | Washer-disinfectors - Part 5: Test soils and methods for demonstrating cleaning efficacy (Adopted ISO/TS 15883-5:2005, first edition, 2005-11-15) |
BS 6151:1992 | Specification for breathing tubes for use with anaesthetic apparatus and ventilators |
BS 7259-2(1993) : AMD 9349 | NON-ELECTRICAL MEDICAL SUCTION EQUIPMENT - SPECIFICATION FOR SUCTION EQUIPMENT POWERED FROM VACUUM OR PRESSURE SOURCE |
14/30281859 DC : 0 | BS ISO 5361 - ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEAL TUBES AND CONNECTORS |
15/30273269 DC : 0 | BS EN ISO 5366 - ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEOSTOMY TUBES - PART: TUBES AND CONNECTORS FOR USE IN ADULTS |
DIN 254:2003-04 | GEOMETRICAL PRODUCT SPECIFICATIONS (GPS) - SERIES OF CONICAL TAPERS AND TAPER ANGLES - VALUES FOR SETTING TAPER ANGLES AND SETTING HEIGHTS |
ONORM EN ISO 17510-1 : 2009 | SLEEP APNOEA BREATHING THERAPY - PART 1: SLEEP APNOEA BREATHING THERAPY EQUIPMENT |
BS ISO 8835-2:1999 | Inhalational anaesthesia systems Anaesthetic breathing systems for adults |
BS EN ISO 5361:2016 | Anaesthetic and respiratory equipment. Tracheal tubes and connectors |
UNE-EN ISO 80369-3:2017 | Small-bore connectors for liquids and gases in healthcare applications - Part 3: Connectors for enteral applications (ISO 80369-3:2016) |
CSA Z10079.3 : 2003 | MEDICAL SUCTION EQUIPMENT - PART 3: SUCTION EQUIPMENT POWERED FROM A VACUUM OR PRESSURE SOURCE |
13/30272807 DC : 0 | BS ISO 18835 - INHALATIONAL ANAESTHESIA SYSTEMS - DRAW-OVER VAPORIZERS AND ASSOCIATED EQUIPMENT |
12/30244415 DC : DRAFT APR 2012 | BS ISO 27427 - ANAESTHETIC AND RESPIRATORY EQUIPMENT - NEBULIZING SYSTEMS AND COMPONENTS |
UNI EN ISO 8835-3 : 2010 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 3: TRANSFER AND RECEIVING SYSTEMS OF ACTIVE ANAESTHETIC GAS SCAVENGING SYSTEMS |
03/103293 DC : DRAFT JAN 2003 | BS EN ISO 10651-2 - LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 2: HOME CARE VENTILATORS FOR VENTILATOR-DEPENDENT PATIENTS |
01/561640 DC : DRAFT APR 2001 | BS EN ISO 8835-4 - INHALATIONAL ANAESTHESIA SYSTEMS - PART 4: ANAESTHETIC VAPOUR DELIVERY DEVICES |
NF EN ISO 80601-2-12 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
BS EN ISO 5366:2016 | Anaesthetic and respiratory equipment. Tracheostomy tubes and connectors |
CSA Z10079.2 : 2003 : R2013 | MEDICAL SUCTION EQUIPMENT - PART 2: MANUALLY POWERED SUCTION EQUIPMENT |
CSA Z10651.2 : 2006 : R2015 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 2: HOME CARE VENTILATORS FOR VENTILATOR-DEPENDENT PATIENTS |
CSA Z10651.2: 2006 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 2: HOME CARE VENTILATORS FOR VENTILATOR-DEPENDENT PATIENTS |
ISO 5362:2006 | Anaesthetic reservoir bags |
PREN ISO 80369-1 : DRAFT 2009 | SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 1: GENERAL REQUIREMENTS |
BIS IS/ISO 10079-2 : 1999 | MEDICAL SUCTION EQUIPMENT - PART 2: MANUALLY POWERED SUCTION EQUIPMENT |
CSA Z10079.2:2003 | MEDICAL SUCTION EQUIPMENT - PART 2: MANUALLY POWERED SUCTION EQUIPMENT |
CSA Z10079.1 : 2003 | MEDICAL SUCTION EQUIPMENT - PART 1: ELECTRICALLY POWERED SUCTION EQUIPMENT - SAFETY REQUIREMENTS |
17/30325386 DC : 0 | BS ISO 18250-1- CONNECTORS FOR RESERVOIR DELIVERY SYSTEMS - PART 1: GENERAL REQUIREMENTS AND COMMON TEST METHODS |
AAMI ISO 10079-2 : 1999 | MEDICAL SUCTION EQUIPMENT - PART 2: MANUALLY POWERED SUCTION EQUIPMENT |
CSA Z8835.5 : 2006 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 5: ANAESTHETIC VENTILATORS |
CSA Z9918 : 0 | CAPNOMETERS FOR USE WITH HUMANS - REQUIREMENTS |
CSA ISO TS 18835 : 2014 | INHALATIONAL ANAESTHESIA SYSTEMS - DRAW-OVER VAPORIZERS AND ASSOCIATED EQUIPMENT |
I.S. EN ISO 5356-2:2012 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - CONICAL CONNECTORS - PART 2: SCREW-THREADED WEIGHT-BEARING CONNECTORS (ISO 5356-2:2012) |
AAMI ISO 10651-4 : 1999 | LUNG VENTILATORS - PART 4: PARTICULAR REQUIREMENTS FOR OPERATOR-POWERED RESUSCITATORS |
ANSI/AAMI/ISO 80369-6:2016 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 6: CONNECTORS FOR NEURAXIAL APPLICATIONS |
I.S. EN ISO 80601-2-72:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-72: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HOME HEALTHCARE ENVIRONMENT VENTILATORS FOR VENTILATOR-DEPENDENT PATIENTS (ISO 80601-2-72:2015) |
UNI EN ISO 17510-1 : 2009 | SLEEP APNOEA BREATHING THERAPY - PART 1: SLEEP APNOEA BREATHING THERAPY EQUIPMENT |
DIN EN ISO 80369-1:2015-09 (Draft) | SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 1: GENERAL REQUIREMENTS |
ISO 5366-3:2001 | Anaesthetic and respiratory equipment Tracheostomy tubes Part 3: Paediatric tracheostomy tubes |
I.S. EN 13976-2:2011 | RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS |
ISO 10651-5:2006 | Lung ventilators for medical use Particular requirements for basic safety and essential performance Part 5: Gas-powered emergency resuscitators |
ISO 80601-2-12:2011 | Medical electrical equipment Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators |
DIN EN ISO 8835-5:2009-07 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 5: ANAESTHESIA VENTILATORS |
DIN EN ISO 10079-1:2016-05 | MEDICAL SUCTION EQUIPMENT - PART 1: ELECTRICALLY POWERED SUCTION EQUIPMENT (ISO 10079-1:2015) |
DIN EN ISO 10079-2:2014-09 | Medical suction equipment - Part 2: Manually powered suction equipment (ISO 10079-2:2014); German version EN ISO 10079-2:2014 |
BS EN ISO 8185:2007 | Respiratory tract humidifiers for medical use. Particular requirements for respiratory humidification systems |
ISO 5366:2016 | Anaesthetic and respiratory equipment — Tracheostomy tubes and connectors |
BS EN ISO 17510-1:2009 | Sleep apnoea breathing therapy Sleep apnoea breathing therapy equipment |
ISO 9360-1:2000 | Anaesthetic and respiratory equipment — Heat and moisture exchangers (HMEs) for humidifying respired gases in humans — Part 1: HMEs for use with minimum tidal volumes of 250 ml |
BS EN ISO 9360-2:2009 | Anaesthetic and respiratory equipment. Heat and moisture exchangers (HMEs) for humidifying respired gases in humans HMEs for use with tracheostomized patients having minimum tidal volumes of 250 ml |
UNE-EN ISO 10079-3:2014 | Medical suction equipment - Part 3: Suction equipment powered from a vacuum or positive pressure gas source (ISO 10079-3:2014) |
ISO 1119:2011 | Geometrical product specifications (GPS) — Series of conical tapers and taper angles |
ISO 17510-2:2007 | Sleep apnoea breathing therapy Part 2: Masks and application accessories |
BS EN 1820:2005 | Anaesthetic reservoir bags |
BS EN ISO 10651-6:2009 | Lung ventilators for medical use. Particular requirements for basic safety and essential performance Home-care ventilatory support devices |
BS EN 13544-1 : 2007 | RESPIRATORY THERAPY EQUIPMENT - PART 1: NEBULIZING SYSTEMS AND THEIR COMPONENTS |
BS EN ISO 10079-3:2014 | Medical suction equipment Suction equipment powered from a vacuum or positive pressure gas source |
ISO 80601-2-72:2015 | Medical electrical equipment — Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients |
ISO 80369-7:2016 | Small-bore connectors for liquids and gases in healthcare applications Part 7: Connectors for intravascular or hypodermic applications |
BS EN 13718-2:2015 | Medical vehicles and their equipment. Air ambulances Operational and technical requirements for air ambulances |
BS EN ISO 10651-2:2004 | Lung ventilators for medical use. Particular requirements for basic safety and essential performance Home care ventilators for ventilator-dependent patients |
ISO 23328-2:2002 | Breathing system filters for anaesthetic and respiratory use — Part 2: Non-filtration aspects |
ISO 10651-6:2004 | Lung ventilators for medical use Particular requirements for basic safety and essential performance Part 6: Home-care ventilatory support devices |
ISO 5361:2016 | Anaesthetic and respiratory equipment — Tracheal tubes and connectors |
IEC 60601-2-13:2003+AMD1:2006 CSV | Medical electrical equipment - Part 2-13: Particular requirements for the safety and essential performance of anaesthetic systems |
ISO/TS 15883-5:2005 | Washer-disinfectors Part 5: Test soils and methods for demonstrating cleaning efficacy |
ISO 80601-2-13:2011 | Medical electrical equipment Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation |
I.S. EN 13718-2:2015 | MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS FOR AIR AMBULANCES |
ISO 8835-4:2004 | Inhalational anaesthesia systems Part 4: Anaesthetic vapour delivery devices |
BS EN 1282-2 : 2005 | TRACHEOSTOMY TUBES - PART 2: PAEDIATRIC TUBES |
UNE-EN ISO 10079-2:2014 | Medical suction equipment - Part 2: Manually powered suction equipment (ISO 10079-2:2014) |
ISO 10079-3:2014 | Medical suction equipment Part 3: Suction equipment powered from a vacuum or positive pressure gas source |
BS EN ISO 5366-1:2004 | Anaesthetic and respiratory equipment. Tracheostomy tubes Tubes and connectors for use in adults |
UNI EN ISO 80601-2-13 : 2013 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-13: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AN ANAESTHETIC WORKSTATION |
I.S. EN 13718-2:2015+A1:2020 | MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS FOR AIR AMBULANCES |
ISO 5366-1:2000 | Anaesthetic and respiratory equipment Tracheostomy tubes Part 1: Tubes and connectors for use in adults |
DIN EN 80369-5:2017-10 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS (IEC 80369-5:2016 + COR.1:2017) |
EN ISO 80601-2-72:2015 | Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients (ISO 80601-2-72:2015) |
EN ISO 5361:2016 | Anaesthetic and respiratory equipment - Tracheal tubes and connectors (ISO 5361:2016) |
EN ISO 10651-2:2009 | Lung ventilators for medical use - Particular requirements for basic safety and essential performance - Part 2: Home care ventilators for ventilator-dependent patients (ISO 10651-2:2004) |
EN 1820:2005+A1:2009 | Anaesthetic reservoir bags (ISO 5362:2000, modified) |
EN ISO 8835-4:2009 | Inhalational anaesthesia systems - Part 4: Anaesthetic vapour delivery devices (ISO 8835-4:2004) |
EN ISO 10651-6:2009 | Lung ventilators for medical use - Particular requirements for basic safety and essential performance - Part 6: Home-care ventilatory support devices (ISO 10651-6:2004) |
EN ISO 8835-5:2009 | Inhalational anaesthesia systems - Part 5: Anaesthetic ventilators (ISO 8835-5:2004) |
EN ISO 10079-2:2014 | Medical suction equipment - Part 2: Manually powered suction equipment (ISO 10079-2:2014) |
EN ISO 17510-2:2009 | Sleep apnoea breathing therapy - Part 2: Masks and application accessories (ISO 17510-2:2007) |
EN ISO 10079-3:2014 | Medical suction equipment - Part 3: Suction equipment powered from a vacuum or positive pressure gas source (ISO 10079-3:2014) |
EN ISO 80369-3:2016 | Small-bore connectors for liquids and gases in healthcare applications - Part 3: Connectors for enteral applications (ISO 80369-3:2016) |
EN ISO 9360-1:2009 | Anaesthetic and respiratory equipment - Heat and moisture exchangers (HMEs) for humidifying respired gases in humans - Part 1: HMEs for use with minimum tidal volumes of 250 ml (ISO 9360-1:2000) |
EN ISO 1119:2011 | Geometrical product specifications (GPS) - Series of conical tapers and taper angles (ISO 1119:2011) |
EN ISO 5367:2014 | Anaesthetic and respiratory equipment - Breathing sets and connectors (ISO 5367:2014) |
EN ISO 8835-2:2009 | Inhalational anaesthesia systems - Part 2: Anaesthetic breathing systems (ISO 8835-2:2007) |
12/30210881 DC : DRAFT APR 2012 | BS EN ISO 5367 - ANAESTHETIC AND RESPIRATORY EQUIPMENT - BREATHING SETS AND CONNECTORS |
CSA ISO 27427 : 2014 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - NEBULIZING SYSTEMS AND COMPONENTS |
BS ISO 11712:2009 | Anaesthetic and respiratory equipment. Supralaryngeal airways and connectors |
13/30290370 DC : 0 | BS ISO 17510 - MEDICAL DEVICES - SLEEP APNOEA BREATHING THERAPY - MASKS AND APPLICATION ACCESSORIES |
I.S. EN ISO 80369-7:2017 COR 2017 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 7: CONNECTORS FOR INTRAVASCULAR OR HYPODERMIC APPLICATIONS (ISO 80369-7:2016, CORRECTED VERSION 2016-12-01) |
NF EN ISO 80369-1 : 2011 | SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 1: GENERAL REQUIREMENTS |
BS EN ISO 8835-3 : 2009 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 3: TRANSFER AND RECEIVING SYSTEMS OF ACTIVE ANAESTHETIC GAS SCAVENGING SYSTEMS |
I.S. EN ISO 8835-5:2009 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 5: ANAESTHESIA VENTILATORS |
I.S. EN ISO 10651-2:2009 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 2: HOME CARE VENTILATORS FOR VENTILATOR-DEPENDENT PATIENTS |
BS ISO 27427:2013 | Anaesthetic and respiratory equipment. Nebulizing systems and components |
CSA ISO 11196 : 0 | ANAESTHETIC GAS MONITORS |
CSA Z10651.3 : 0 | LUNG VENTILATORS FOR MEDICAL USE - PART 3: PARTICULAR REQUIREMENTS FOR EMERGENCY AND TRANSPORT VENTILATORS |
ISO/TS 18835:2004 | Inhalational anaesthesia systems Draw-over vaporizers and associated equipment |
05/30128373 DC : DRAFT JAN 2005 | ISO 7396-2 - MEDICAL GAS PIPELINE SYSTEMS - PART 2: ANAESTHETIC GAS SCAVENGING DISPOSAL SYSTEMS - BASIC REQUIREMENTS |
CAN/CSA-C22.2 NO. 80601-2-70:17 | Medical electrical equipment — Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipment (Adopted ISO 80601-2-70:2015, first edition, 2015-01 , with Canadian deviations) |
EN ISO 80369-7:2017 | Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications (ISO 80369-7:2016, Corrected version 2016-12-01) |
ANSI/AAMI/ISO 80369-5:2016 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS |
10/30209612 DC : 0 | BS ISO 1119 - GEOMETRICAL PRODUCT SPECIFICATIONS (GPS) - SERIES OF CONICAL TAPERS AND TAPER ANGLES |
NF EN 80369-5 : 2017 | SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS |
DIN EN ISO 5367:2015-02 | Anaesthetic and respiratory equipment - Breathing sets and connectors (ISO 5367:2014) |
I.S. EN ISO 5367:2014 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - BREATHING SETS AND CONNECTORS (ISO 5367:2014) |
BS 7734:1994 | Specification for anaesthetic circle breathing systems |
BS EN ISO 5356-2:2012 | Anaesthetic and respiratory equipment. Conical connectors Screw-threaded weight-bearing connectors |
PREN ISO 1119 : DRAFT 2010 | GEOMETRICAL PRODUCT SPECIFICATIONS (GPS) - SERIES OF CONICAL TAPERS AND TAPER ANGLES |
ASTM F 2560 : 2006 | Standard Specification for Supralaryngeal Airways and Connectors |
CSA ISO 5367 : 2014 | BREATHING TUBES INTENDED FOR USE WITH ANAESTHETIC APPARATUS AND VENTILATORS |
BS 3849-2:1988 | Conical connectors for anaesthetic and respiratory equipment Specification for screw-threaded weight-bearing connectors |
I.S. EN ISO 8835-3:2009 | INHALATIONAL ANAESTHESIA SYSTEMS - PART 3: TRANSFER AND RECEIVING SYSTEMS OF ACTIVE ANAESTHETIC GAS SCAVENGING SYSTEMS |
ISO 10079-1:2015 | Medical suction equipment Part 1: Electrically powered suction equipment |
CSA Z5361 : 2003 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEAL TUBES AND CONNECTORS |
ISO 80369-1:2010 | Small-bore connectors for liquids and gases in healthcare applications Part 1: General requirements |
UNE-EN ISO 5366:2017 | Anaesthetic and respiratory equipment - Tracheostomy tubes and connectors (ISO 5366:2016) |
CSA Z15883-5 : 2009 : R2014 | WASHER-DISINFECTORS - PART 5: TEST SOILS AND METHODS FOR DEMONSTRATING CLEANING EFFICACY |
UNI EN ISO 5356-2 : 2013 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - CONICAL CONNECTORS - PART 2: SCREW-THREADED WEIGHT-BEARING CONNECTORS |
CEI EN 60601-2-13 : 2007 | MEDICAL ELECTRICAL EQUIPMENT - PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY AND ESSENTIAL PERFORMANCE OF ANAESTHETIC SYSTEMS |
EN 13976-2:2011 | Rescue systems - Transportation of incubators - Part 2: System requirements |
ISO 18835:2015 | Inhalational anaesthesia systems Draw-over anaesthetic systems |
ISO 27427:2013 | Anaesthetic and respiratory equipment — Nebulizing systems and components |
DIN EN ISO 1119:2012-04 | Geometrical product specifications (GPS) - Series of conical tapers and taper angles (ISO 1119:2011) |
BS EN ISO 17510-2:2009 | Sleep apnoea breathing therapy Masks and application accessories |
ISO 8185:2007 | Respiratory tract humidifiers for medical use Particular requirements for respiratory humidification systems |
UNE-EN ISO 1119:2012 | Geometrical product specifications (GPS) - Series of conical tapers and taper angles (ISO 1119:2011) |
ISO 17510-1:2007 | Sleep apnoea breathing therapy Part 1: Sleep apnoea breathing therapy equipment |
BS EN ISO 1119:2011 | Geometrical product specifications (GPS). Series of conical tapers and taper angles |
BS EN ISO 8835-5:2009 | Inhalational anaesthesia systems Anaesthesia ventilators |
BS EN ISO 8835-4:2009 | Inhalational anaesthesia systems Anaesthetic vapour delivery devices |
ISO 10079-2:2014 | Medical suction equipment Part 2: Manually powered suction equipment |
DIN EN ISO 80369-7:2017-10 | Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications (ISO 80369-7:2016, Corrected version 2016-12-01) |
DIN EN ISO 10079-2:2000-03 | MEDICAL SUCTION EQUIPMENT - PART 2: MANUALLY POWERED SUCTION EQUIPMENT (ISO 10079-2:2014) |
EN ISO 11196 : 1997 | ANAESTHETIC GAS MONITORS |
DIN EN ISO 9360-1:2009-09 | Anaesthetic and respiratory equipment - Heat and moisture exchangers (HMEs) for humidifying respired gases in humans - Part 1: HMEs for use with minimum tidal volumes of 250 ml (ISO 9360-1:2000) |
DIN EN ISO 8185:2009-07 | RESPIRATORY TRACT HUMIDIFIERS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR RESPIRATORY HUMIDIFICATION SYSTEMS |
DIN EN 13976-2:2011-08 | RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS |
EN 60601-2-13 : 2006 AMD 1 2007 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-13: PARTICULAR REQUIREMENTS FOR THE SAFETY AND ESSENTIAL PERFORMANCE OF ANAESTHETIC SYSTEMS |
DIN EN ISO 9360-2:2009-09 | Anaesthetic and respiratory equipment - Heat and moisture exchangers (HMEs) for humidifying respired gases in humans - Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250 ml (ISO 9360-2:2001) |
DIN EN 1282-2:2009-12 | TRACHEOSTOMY TUBES - PART 2: PAEDIATRIC TUBES |
EN 60601-2-12:2006 | Medical electrical equipment - Part 2-12: Particular requirements for the safety of lung ventilators - Critical care ventilators |
DIN EN ISO 10079-3:2000-03 | MEDICAL SUCTION EQUIPMENT - PART 3: SUCTION EQUIPMENT POWERED FROM A VACUUM OR POSITIVE PRESSURE GAS SOURCE (ISO 10079-3:2014) |
ONORM EN 794-3 : 2010 | LUNG VENTILATORS - PART 3: PARTICULAR REQUIREMENTS FOR EMERGENCY AND TRANSPORT VENTILATORS |
CSA Z9360.1 : 2007 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - HEAT AND MOISTURE EXCHANGERS (HMES) FOR HUMIDIFYING RESPIRED GASES IN HUMANS - PART 1: HMES FOR USE WITH MINIMUM TIDAL VOLUMES OF 250 ML |
CSA Z10651-5 : 2008 : R2018 | Lung Ventilators for Medical Use - Particular Requirements for Basic Safety and Essential Performance - Part 5: Gas-Powered Emergency Resuscitators |
CSA Z9360.2:2007 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - HEAT AND MOISTURE EXCHANGERS (HMES) FOR HUMIDIFYING RESPIRED GASES IN HUMANS - PART 2: HMES FOR USE WITH TRACHEOSTOMIZED PATIENTS HAVING MINIMUM TIDAL VOLUMES OF 250 ML |
CAN/CSA-ISO 5356-2:18 | CAN/CSA-ISO 5356-2:18 - Anaesthetic and respiratory equipment — Conical connectors — Part 2: Screw-threaded weight-bearing connectors (Adopted ISO 5356-2:2012, third edition, 2012-11-15) |
CSA Z10651-5 : 2008 : R2013 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 5: GAS-POWERED EMERGENCY RESUSCITATORS |
CSA Z10651-5 : 2008 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 5: GAS-POWERED EMERGENCY RESUSCITATORS |
CSA ISO 5361 : 2014 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - TRACHEAL TUBES AND CONNECTORS |
CSA Z9360.1 : 2007 : R2012 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - HEAT AND MOISTURE EXCHANGERS (HMES) FOR HUMIDIFYING RESPIRED GASES IN HUMANS - PART 1: HMES FOR USE WITH MINIMUM TIDAL VOLUMES OF 250 ML |
CSA Z9360.2 : 2007:R2012 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - HEAT AND MOISTURE EXCHANGERS (HMES) FOR HUMIDIFYING RESPIRED GASES IN HUMANS - PART 2: HMES FOR USE WITH TRACHEOSTOMIZED PATIENTS HAVING MINIMUM TIDAL VOLUMES OF 250 ML |
CAN/CSA-ISO 10079-1:16 | Medical suction equipment - Part 1: Electrically powered suction equipment (Adopted ISO 10079-1:2015, third edition, 2015-11-01) |
CSA Z10651-5 : 2008 : INC : UPD 1 : 2011 | LUNG VENTILATORS FOR MEDICAL USE - PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - PART 5: GAS-POWERED EMERGENCY RESUSCITATORS |
UNE-EN 13544-1:2007 | Respiratory therapy equipment - Part 1: Nebulizing systems and their components |
ONORM EN ISO 5367 : 2015 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - BREATHING SETS AND CONNECTORS (ISO 5367:2014) |
ISO 3040:2016 | Geometrical product specifications (GPS) Dimensioning and tolerancing Cones |
ISO 5356-2:2012 | Anaesthetic and respiratory equipment — Conical connectors — Part 2: Screw-threaded weight-bearing connectors |
ISO 5367:2014 | Anaesthetic and respiratory equipment — Breathing sets and connectors |
ISO 4135:2001 | Anaesthetic and respiratory equipment Vocabulary |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.