High-Temperature Instrumentation and Control Cables
Hardcopy , PDF
English
10-02-2011
FOREWORD
SCOPE
1. REFERENCED STANDARDS AND GENERAL INFORMATION
Referenced Standards
Introduction
Types
Instrumentation Cables
300V Control Cables
600V Control Cables
1000V Control Cables
2. CONDUCTORS
Conductor Material
Conductor Construction for Other Than Thermocouple
Stranding
Thermocouple Conductor Construction
3. INSULATION
Materials
Thickness
4. CIRCUIT IDENTIFICATION
Unpaired Cables
Paired Cables
Thermocouple or Thermocouple Extension Lead Wires
5. ASSEMBLY
Electrical Testing of Individual Conductors
Color Sequence of Conductors
Shielding of Conductors, Component Groups or Cable Core
6. JACKETS
Introduction
Materials
Thickness
7. TEST PROCEDURES
Introduction
Physical Requirements
Test Temperature
Type of Testing Machine
Tensile Strength Tests
Alternative Tensile Strength Test
Elongation Test
Alternative Elongation Test Method
Aging Test
Air Oven Test
Oil Immersion Test
Heat Shock Test
Heat Distortion Test
Test Specimen
Test Specimen for Insulation
Test Specimen for Jackets 50 Mil or Greater in Thickness
Test Specimen for Jackets Less than 50 Mil Thickness
Test Procedure
Cold Bend Test
Thickness Determination
Flame Propagation Test
Electrical Tests
Voltage Tests
General
Alternating Current Voltage Test
Direct-Current Voltage Test
Direct-Current Spark Test
Impulse Dielectric Voltage Test
Test Requirements for Cables Without Metallic Shield
Test Requirements for Cables With Metallic Shield
Insulation Resistance Test
Test Apparatus
Test Procedure
Dielectric Constant (SIC) Test Procedure
TABLES
4.1 Colour Sequence for Instrumentation and Control Cables
5.1 Test Voltages, Completed Cables
7.1 Test Voltages, Insulated Conductors
7.2 Temperature Correction Factors for Insulation
Resistance to 15.6 deg C (60 deg F)
7.3 Stranding Factor
Covers requirements and test procedures for a series of multiple-conductor, high-temperature instrumentation and control cables for use in ducts, conduit and trays. Contains general requirements and test procedures. Addresses high-temperature instrumentation and control cables insulated and jacketed with FEP fluorocarbons, with ETFE fluoropolymers, crosslinked (thermoset) polyolefin (XLPO), and with ECTFE fluoropolymers.
DevelopmentNote |
Available along with NEMA HP 100.1, NEMA HP 100.2, NEMA HP 100.3 & NEMA HP 100.4 as a SET. (10/2002)
|
DocumentType |
Standard
|
Pages |
83
|
PublisherName |
National Electrical Manufacturers Association
|
Status |
Current
|
IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
NEMA HP 100.4 : 1991(R2010) | HIGH TEMPERATURE INSTRUMENTATION AND CONTROL CABLES INSULATED AND JACKETED WITH ECTFE FLUOROPOLYMERS |
NEMA HP 100.1 : 1991(R2010) | HIGH TEMPERATURE INSTRUMENTATION AND CONTROL CABLES INSULATED AND JACKETED WITH FEP FLUOROCARBONS |
NEMA HP 100.3 : 1991(R2010) | HIGH TEMPERATURE INSTRUMENTATION AND CONTROL CABLES INSULATED AND JACKETED WITH CROSS-LINKED (THERMOSET) POLYOLEFIN (XLPO) |
NEMA HP 100.2 : 1991(R2010) | HIGH TEMPERATURE INSTRUMENTATION AND CONTROL CABLES INSULATED AND JACKETED WITH ETFE FLUOROPOLYMERS |
IEEE 3001.5-2013 | IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems |
NEMA HP 100.4 : 1991(R2010) | HIGH TEMPERATURE INSTRUMENTATION AND CONTROL CABLES INSULATED AND JACKETED WITH ECTFE FLUOROPOLYMERS |
IEEE 383-2015 | IEEE Standard for Qualifying Electric Cables and Splices for Nuclear Facilities |
ASTM D 3032 : 2016 : REDLINE | Standard Test Methods for Hookup Wire Insulation |
NEMA HP 100.2 : 1991(R2010) | HIGH TEMPERATURE INSTRUMENTATION AND CONTROL CABLES INSULATED AND JACKETED WITH ETFE FLUOROPOLYMERS |
UL 83:16ED 2017-07-28 | Standard for Thermoplastic-Insulated Wires and Cables |
WC 5-1992 | THERMOPLASTIC-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
ANSI MC96.1 : 1982 | TEMPERATURE MEASUREMENT THERMOCOUPLES |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
WC 3-1992 | RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
NEMA HP 100.1 : 1991(R2010) | HIGH TEMPERATURE INSTRUMENTATION AND CONTROL CABLES INSULATED AND JACKETED WITH FEP FLUOROCARBONS |
ASTM D 257 : 2014 : REDLINE | Standard Test Methods for DC Resistance or Conductance of Insulating Materials |
NEMA HP1 : LATEST | HIGH TEMPERATURE INSULATED WIRE-IMPULSE DIELECTRIC TESTING |
ASTM D 471 : 2016-02 | TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS |
ASTM D 638 : 2014 : REDLINE | Standard Test Method for Tensile Properties of Plastics |
WC 7-1988 | CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
NEMA WC1 : 1982 | ASBESTOS, ASBESTOS VARNISHED CLOTH, AND ASBESTOS THERMOPLASTIC INSULATED WIRES AND CABLES, REQUIREMENTS FOR, |