SOLVENT EXTRACTION PLANTS
Hardcopy
16-08-2021
English
01-01-2017
Chapter 1 - Administration
Chapter 2 - Referenced Publications
Chapter 3 - Definitions
Chapter 4 - General Requirements
Chapter 5 - Bulk Solvent Unloading and Storage
Chapter 6 - Preparation and Meal Finishing Processes
Chapter 7 - Extraction Process
Chapter 8 - Extraction Process Equipment
Annex A - Explanatory Material
Annex B - Description of the Solvent Extraction Process
Annex C - Operational Practices
Annex D - Informational References
Index
Gives: (1) Requirements for the design, construction, and operation of extraction processes that utilize Class I flammable hydrocarbon liquids (2) Requirements for the prevention of fire and explosion in extraction processes and in associated preparation and meal finishing areas (3) A means by which plant fire protection and supervisory personnel can evaluate the processes and operations under their control (4) Guidance to regulatory and inspection officials in determining whether a given facility is being operated in accordance with good practice (5) A workable set of standards for the use of design engineers, architects, and others in the planning and design of new installations
DocumentType |
Standard
|
Pages |
39
|
PublisherName |
National Fire Protection Association
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
NFPA 18A : 2017 | WATER ADDITIVES FOR FIRE CONTROL AND VAPOR MITIGATION |
NFPA 122 : 2015 | FIRE PREVENTION AND CONTROL IN METAL/NONMETAL MINING AND METAL MINERAL PROCESSING FACILITIES |
NFPA 5000 : 2018 | BUILDING CONSTRUCTION AND SAFETY CODE |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
NFPA FIRE PROT GUIDE ON HAZARDOUS MAT : 2010 | FIRE PROTECTION GUIDE TO HAZARDOUS MATERIALS |
NFPA 91 : 2015 | EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS |
NFPA 1 : 2021 | FIRE CODE |
VDI 2592 Blatt 1:2010-12 | Emission control - Oilmills for the production of oil and wholemeal in prepress and extraction facilities |
NFPA 499 : 2017 | CLASSIFICATION OF COMBUSTIBLE DUSTS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
NFPA 497B : 1991 | RECOMMENDED PRACTICE FOR THE CLASSIFICATION OF CLASS II HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
NFPA 497A : 1992 | CLASSIFICATION OF CLASS I HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
NFPA 61 : 2020 | PREVENTION OF FIRES AND DUST EXPLOSIONS IN AGRICULTURAL AND FOOD PROCESSING FACILITIES |
NFPA 32 : 2016 | DRYCLEANING FACILITIES |
NFPA 61 : 2017 | PREVENTION OF FIRES AND DUST EXPLOSIONS IN AGRICULTURAL AND FOOD PROCESSING FACILITIES |
NFPA 30 FRENCH : 1996 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
NFPA 1 : 2018 | FIRE CODE |
NFPA 32:2021 | Standard for Drycleaning Facilities |
NFPA 91 : 2015 | EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS |
NFPA 61 : 2017 | PREVENTION OF FIRES AND DUST EXPLOSIONS IN AGRICULTURAL AND FOOD PROCESSING FACILITIES |
NFPA 780 : 2017 | INSTALLATION OF LIGHTNING PROTECTION SYSTEMS |
NFPA 329 : 2015 | HANDLING RELEASES OF FLAMMABLE AND COMBUSTIBLE LIQUIDS AND GASES |
NFPA 214 : 2016 | WATER-COOLING TOWERS |
NFPA 69 : 2014 | EXPLOSION PREVENTION SYSTEMS |
NFPA 496 : 2017 | PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT |
NFPA 385 : 2017 | TANK VEHICLES FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS |
NFPA 24 : 2016 | INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES |
NFPA 15 : 2017 | WATER SPRAY FIXED SYSTEMS FOR FIRE PROTECTION |
NFPA 10 : 2018 | PORTABLE FIRE EXTINGUISHERS |
NFPA 68 : 2013 | EXPLOSION PROTECTION BY DEFLAGRATION VENTING |
NFPA 14 : 2016 | INSTALLATION OF STANDPIPE AND HOSE SYSTEMS |
ASTM E 136 : 2016-02 | TEST METHOD FOR BEHAVIOUR OF MATERIALS IN A VERTICAL TUBE FURNACE AT 750 DEGREES C |
NFPA 86 : 2015 | OVENS AND FURNACES |
NFPA 220 : 2018 | TYPES OF BUILDING CONSTRUCTION |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
NFPA 13 : 2016 | INSTALLATION OF SPRINKLER SYSTEMS |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
NFPA 77 : 2014 | STATIC ELECTRICITY |
ASME PV CODE 8 SET : 2013 | ASME BOILER AND PRESSURE VESSEL CODE (BPVC) - RULES FOR CONSTRUCTION OF PRESSURE VESSELS (SET) |
NFPA 16 : 2015 | INSTALLATION OF FOAM-WATER SPRINKLER AND FOAM-WATER SPRAY SYSTEMS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.