• Shopping Cart
    There are no items in your cart

S.R. CEN TR 15983:2010

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

STATIONARY SOURCE EMISSIONS - GUIDANCE ON THE APPLICATION OF EN 14181:2004

Available format(s)

Hardcopy , PDF

Withdrawn date

22-03-2016

Language(s)

English

Published date

01-01-2010

€70.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Terms and definitions
3 Symbols and abbreviations
4 General guidance on quality assurance and calibration
5 Application of QAL1
6 Application of QAL2 and AST
7 Calibration and validation of the AMS
8 On-going surveillance and quality assurance of AMS (QAL3)
Annex A (informative) An example of a procedure for
        determining outliers
Annex B (informative) Alternative approaches for dealing
        with low-level clusters of emissions
Annex C (informative) k[v] values
Annex D (informative) Shewhart and EWMA control charts
Bibliography

Gives guidance only on applying the quality assurance levels QAL1, QAL2 and QAL3 as well as the Annual Surveillance Test (AST).

DocumentType
Standard
Pages
46
PublisherName
National Standards Authority of Ireland
Status
Withdrawn

Standards Relationship
CEN/TR 15983:2010 Identical

CEN/TS 15675:2007 Air quality - Measurement of stationary source emissions - Application of EN ISO/IEC 17025:2005 to periodic measurements
ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
EN 15267-3:2007 Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources
ISO 14956:2002 Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
EN ISO 9169:2006 Air quality - Definition and determination of performance characteristics of an automatic measuring system (ISO 9169:2006)
ISO 11095:1996 Linear calibration using reference materials
EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
EN 13284-2:2017 Stationary source emissions - Determination of low range mass concentration of dust - Part 2: Quality assurance of automated measuring systems
EN 14181:2014 Stationary source emissions - Quality assurance of automated measuring systems
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN 12619:2013 Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002)
ISO 14001:2015 Environmental management systems — Requirements with guidance for use
ISO 10012:2003 Measurement management systems — Requirements for measurement processes and measuring equipment
EN ISO 14001:2015 Environmental management systems - Requirements with guidance for use (ISO 14001:2015)
ISO 9001:2015 Quality management systems — Requirements
EN ISO 10012:2003 Measurement management systems - Requirements for measurement processes and measuring equipment (ISO 10012:2003)
EN 14792:2017 Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
ISO 9169:2006 Air quality Definition and determination of performance characteristics of an automatic measuring system

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.