Foreword
1 Scope
2 References
3 Definitions, symbols and abbreviations
3.1 Definitions
3.2 Symbols
3.3 Abbreviations
4 Introduction
5 Uncertainty contributions specific to an Anechoic Chamber
with a Ground Plane
5.1 Effects of the metal shielding
5.1.1 Resonances
5.1.2 Imaging of antennas (or an EUT)
5.2 Effects of the radio absorbing materials
5.2.1 Introduction
5.2.2 Pyramidal absorbers
5.2.3 Wedge absorbers
5.2.4 Ferrite tiles
5.2.5 Ferrite grids
5.2.6 Urethane/ferrite hybrids
5.2.7 Performance comparison
5.2.8 Reflection in an Anechoic Chamber with a Ground
Plane
5.2.9 Mutual coupling due to imaging in the absorbing
material
5.2.10 Extraneous reflections
5.3 Effects of the ground plan
5.3.1 Reflections
5.3.2 Mutual coupling between antennas and in the ground
plane
5.4 Other effects
5.4.1 Range length and measurement distance
5.4.2 Antenna mast, turntable and mounting fixtures
5.4.3 Test antenna height limitations
5.4.4 Test antenna cabling
5.4.5 EUT cabling
5.4.6 Positioning of the EUT and antennas
6 Verification procedure for an Anechoic Chamber with a Ground
Plane
6.1 Introduction
6.2 Normalized site attenuation
6.2.1 Anechoic Chamber
6.2.2 Anechoic Chamber with a Ground Plane
6.2.3 Improvements to the formulae for E DH max and
E DV max
6.2.4 Mutual coupling
6.3 Overview of the verification procedure
6.3.1 Apparatus required
6.3.2 Site preparation
6.3.3 Measurement configuration
6.3.4 What to record
6.4 Verification procedure
6.4.1 Procedure 1: 30 MHz to 1 000 MHz
6.4.2 Alternative procedure: 30 MHz to 1 000 MHz
6.4.3 Procedure 2: 1 GHz to 12,75 GHz
6.5 Processing the results of the verification procedure
6.5.1 Introduction
6.5.2 Procedure 1: 30 MHz to 1 000 MHz
6.5.3 Procedure 2: 1 GHz to 12,75 GHz
6.5.4 Report format
6.6 Calculation of measurement uncertainty (Procedure 1)
6.6.1 Uncertainty contribution, direct attenuation
measurement
6.6.2 Uncertainty contribution, NSA measurement
6.6.3 Expanded uncertainty of the verification procedure
6.7 Calculation of measurement uncertainty (Procedure 2)
6.7.1 Uncertainty contribution, direct attenuation
measurement
6.7.2 Uncertainty contribution, NSA measurement
6.7.3 Expanded uncertainty of the verification procedure
6.8 Summary
7 Test methods
7.1 Introduction
7.1.1 Site preparation
7.1.2 Preparation of the EUT
7.1.3 Standard antennas
7.1.4 Mutual coupling and mismatch loss correction
factors
7.1.5 Power supplies to the EUT
7.1.6 Restrictions
7.2 Transmitter tests
7.2.1 Frequency error (30 MHz to 1 000 MHz)
7.2.1.1 Apparatus required
7.2.1.2 Method of measurement
7.2.1.3 Procedure for completion of the overall
results sheet
7.2.1.4 Log book entries
7.2.1.5 Statement of results
7.2.2 Expanded uncertainty for Frequency error test
7.2.3 Effective radiated power (30 MHz to 1 000 MHz)
7.2.3.1 Apparatus required
7.2.3.2 Method of measurement
7.2.3.3 Procedure for completion of the overall
results sheet
7.2.3.4 Log book entries
7.2.3.5 Statement of results
7.2.4 Measurement uncertainty for Effective radiated
power
7.2.4.1 Uncertainty contributions: Stage 1:
EUT measurement
7.2.4.2 Uncertainty contributions: Stage 2:
Substitution measurement
7.2.4.3 Expanded uncertainty of the ERP
measurement
7.2.5 Spurious emissions (30 MHz to 4 Ghz or 12,75 GHz)
7.2.5.1 Apparatus required
7.2.5.2 Method of measurement
7.2.5.3 Procedure for completion of the results
sheets
7.2.5.4 Log book entries
7.2.5.5 Statement of results
7.2.6 Measurement uncertainty for Spurious emissions
7.2.6.1 Uncertainty contributions: Stage 1:
EUT measurement
7.2.6.2 Uncertainty contributions: Stage 2:
Substitution measurement
7.2.6.3 Expanded uncertainty of the Spurious
emission
7.2.7 Adjacent channel power
7.3 Receiver tests
7.3.1 Sensitivity tests (30 MHz to 1 000 MHz)
7.3.1.1 Apparatus required
7.3.1.2 Method of measurement
7.3.1.3 Procedure for completion of the overall
results sheet
7.3.1.4 Log book entries
7.3.1.5 Statement of results
7.3.2 Measurement uncertainty for Receiver sensitivity
7.3.2.1 Uncertainty contributions: Stage 1:
Determination of transform factor
7.3.2.2 Uncertainty contributions: Stage 2:
EUT measurement
7.3.2.3 Expanded uncertainty of the receiver
sensitivity measurement
7.3.3 Co-channel rejection
7.3.4 Adjacent channel selectivity
7.3.5 Intermodulation immunity
7.3.6 Blocking immunity in desensitization
7.3.7 Spurious response immunity to radiated fields
Annex A: Bibliography
History
Gives background to the subject of measurement uncertainty and proposes extensions and improvements relevant to radiated measurements.
Committee |
ERM RP02
|
DocumentType |
Standard
|
Pages |
115
|
PublisherName |
European Telecommunications Standards Institute
|
Status |
Current
|
TS 103 051 : 1.1.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); EXPANDED MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS |
CSA ISO/IEC TR 18047-6 : 2013 | INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE CONFORMANCE TEST METHODS - PART 6: TEST METHODS FOR AIR INTERFACE COMMUNICATIONS AT 860 MHZ TO 960 MHZ |
PD ISO/IEC TR 18047-6:2011 | Information technology. Radio frequency identification device conformance test methods Test methods for air interface communications at 860 MHz to 960 MHz |
EN 302 291-1 : 1.1.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SHORT RANGE DEVICES (SRD); CLOSE RANGE INDUCTIVE DATA COMMUNICATION EQUIPMENT OPERATING AT 13,56 MHZ; PART 1: TECHNICAL CHARACTERISTICS AND TEST METHODS |
EN 301 598 : 2.1.1 | WHITE SPACE DEVICES (WSD); WIRELESS ACCESS SYSTEMS OPERATING IN THE 470 MHZ TO 790 MHZ TV BROADCAST BAND; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF DIRECTIVE 2014/53/EU |
BS ISO/IEC 18047-6:2017 | Information technology. Radio frequency identification device conformance test methods Test methods for air interface communications at 860 MHz to 960 MHz |
ISO/IEC 18047-6:2017 | Information technology — Radio frequency identification device conformance test methods — Part 6: Test methods for air interface communications at 860 MHz to 960 MHz |
TR 102 273-6 : 1.2.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES PART 6: TEST FIXTURES |
TR 102 215 : 1.3.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); RECOMMENDED APPROACH, AND POSSIBLE LIMITS FOR MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS ABOVE 1 GHZ |
EG 202 290 : 1.1.1 FINAL DRAFT | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); MEASUREMENT UNCERTAINTIES AND TEST METHODOLOGIES FROM 1 GHZ TO 40 GHZ |
12/30257202 DC : 0 | BS ISO/IEC 18047-6 - INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE CONFORMANCE TEST METHODS - PART 6: TEST METHODS FOR AIR INTERFACE COMMUNICATIONS AT 860 MHZ TO 960 MHZ |
ISO/IEC TR 18047-6:2011 | Information technology Radio frequency identification device conformance test methods Part 6: Test methods for air interface communications at 860 MHz to 960 MHz |
EN 300 330 : 2.1.1 | SHORT RANGE DEVICES (SRD); RADIO EQUIPMENT IN THE FREQUENCY RANGE 9 KHZ TO 25 MHZ AND INDUCTIVE LOOP SYSTEMS IN THE FREQUENCY RANGE 9 KHZ TO 30 MHZ; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF DIRECTIVE 2014/53/EU |
EN 300 220-1 : 2.4.1 | SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1000 MHZ; PART 1: TECHNICAL CHARACTERISTICS AND METHODS OF MEASUREMENT |
EN 301 893 : 1.8.1 | 5 GHZ RLAN; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF DIRECTIVE 2014/53/EU |
16/30315793 DC : 0 | BS ISO/IEC 18047-6 - INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE CONFORMANCE TEST METHODS - PART 6: TEST METHODS FOR AIR INTERFACE COMMUNICATIONS AT 860 MHZ TO 960 MHZ |
ECMA/TR 94 : 1ED 2007 | ASSESSMENT OF THE HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS FOR LOW POWER ELECTRONIC AND ELECTRICAL APPARATUS ACCORDING TO EN 50371:2002 |
CSA ISO/IEC TR 18047-6 : 2013 : R2017 | INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE CONFORMANCE TEST METHODS - PART 6: TEST METHODS FOR AIR INTERFACE COMMUNICATIONS AT 860 MHZ TO 960 MHZ |
EN 300 328 : 2.1.1 | WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2,4 GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF DIRECTIVE 2014/53/EU |
TR 102 273-1-2 : 1.2.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 2: EXAMPLES AND ANNEXES |
TR 100 028-1 : 1.4.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 1 |
EN 50147-2 : 1996 | ANECHOIC CHAMBERS - PART 2: ALTERNATIVE TEST SITE SUITABILITY WITH RESPECT TO SITE ATTENUATION |
TR 102 273-1-1 : 1.2.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 1: INTRODUCTION |
ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
TR 100 027 : 1.2.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); METHODS OF MEASUREMENT FOR PRIVATE MOBILE RADIO EQUIPMENT |
TR 100 028-2 : 1.4.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 2 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.