Foreword
1 Scope
2 References
3 Definitions and abbreviations
  3.1 Definitions
  3.2 Abbreviations
4 Monitoring information and functions
  4.1 Basic information on power and cooling systems
  4.2 Supervision functions
5 Network architecture
  5.1 Alarm loops
  5.2 Local intelligence
  5.3 Remote intelligence
  5.4 Hybrid solutions
6 Supervisor functions and performance
  6.1 Supervision functions
  6.2 Supervision performance
  6.3 Data integrity, coherence, reliability
  6.4 Software working and development environment
7 Cost consideration
Annex A: Common monitoring and supervision operation sequences
Annex B: MIB template
Annex C: Message format
Annex D: SCADA systems
History

Assists to identify the type and minimum set of information required for monitoring and management and the possible network architectures for heterogeneous power and cooling system equipment.

Committee
EE 02
DocumentType
Standard
Pages
32
PublisherName
European Telecommunications Standards Institute
Status
Current

ES 202 336-6 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 6: AIR CONDITIONING SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-7 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 7: OTHER UTILITIES SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-4 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 4: AC DISTRIBUTION POWER SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-1 : 1.2.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS) - PART 1: GENERIC INTERFACE
ES 202 336-8 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 8: REMOTE POWER FEEDING SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-2 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 2: DC POWER SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-11 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 11: BATTERY SYSTEM WITH INTEGRATED CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-9 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 9: ALTERNATIVE POWER SYSTEMS

IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
EN 300 386 : 1.6.1 TELECOMMUNICATION NETWORK EQUIPMENT; ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF THE DIRECTIVE 2014/30/EU
IEC 61970-301:2016 Energy management system application program interface (EMS-API) - Part 301: Common information model (CIM) base
EN 300 132-2 : 2.4.6 ENVIRONMENTAL ENGINEERING (EE); POWER SUPPLY INTERFACE AT THE INPUT TO TELECOMMUNICATIONS AND DATACOM (ICT) EQUIPMENT; PART 2: OPERATED BY -48 V DIRECT CURRENT (DC)
EN 300 132-3 : 1.2.1 ENVIRONMENTAL ENGINEERING (EE); POWER SUPPLY INTERFACE AT THE INPUT TO TELECOMMUNICATIONS EQUIPMENT; PART 3: OPERATED BY RECTIFIED CURRENT SOURCE, ALTERNATING CURRENT SOURCE OR DIRECT CURRENT SOURCE UP TO 400 V
TR 102 121 : 1.2.1 ENVIRONMENTAL ENGINEERING (EE); GUIDANCE FOR POWER DISTRIBUTION TO TELECOMMUNICATION AND DATACOM EQUIPMENT
IEC 60839-5-4:1991 Alarm systems - Part 5: Requirements for alarm transmission systems - Section 4: Alarm transmission systems using dedicated alarm transmission paths
ISO/IEC Guide 73:2002 Risk management Vocabulary Guidelines for use in standards
ETS 300 132-1 : 20001 EQUIPMENT ENGINEERING (EE) - POWER SUPPLY INTERFACE AT THE INPUT TO TELECOMMUNICATIONS EQUIPMENT - OPERATED BY ALTERNATING CURRENT (AC) DERIVED FROM DIRECT CURRENT (DC) SOURCES
IEC TR 62357:2003 Power system control and associated communications - Reference architecture for object models, services and protocols
TR 102 489 : 1.4.1 ENVIRONMENTAL ENGINEERING (EE); EUROPEAN TELECOMMUNICATIONS STANDARD FOR EQUIPMENT PRACTICE; THERMAL MANAGEMENT GUIDANCE FOR EQUIPMENT AND ITS DEPLOYMENT
EN 302 099 : 2.1.1 ENVIRONMENTAL ENGINEERING (EE); POWERING OF EQUIPMENT IN ACCESS NETWORK

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.