• Shopping Cart
    There are no items in your cart

UNE-EN 50121-5:2018

Current

Current

The latest, up-to-date edition.

Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus

Available format(s)

Hardcopy , PDF

Published date

03-01-2018

€86.40
Excluding VAT

This European standard applies to emission and immunity aspects of EMC for electrical and electronicapparatus and systems intended for use in railway fixed installations for power supply. This includesthe power feed to the apparatus, the apparatus itself with its protective control circuits, trackside itemssuch as switching stations, power autotransformers, booster transformers, substation powerswitchgear and power switchgear to other longitudinal and local supplies.Filters operating at railway system voltage (for example, for harmonic suppression or power factorcorrection) are not included in this standard since each site has special requirements. Filters wouldnormally have separate enclosures with separate rules for access. If electromagnetic limits arerequired, these will appear in the specification for the equipment.If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators,e.g. transponder systems), then the radiated emission requirement in this standard are not intended tobe applicable to the intentional transmission from a radio-transmitter as defined by the ITU.The frequency range considered is from DC to 400 GHz. No measurements need to be performed atfrequencies where no requirement is specified.Emission and immunity limits are given for items of apparatus which are situated:a) within the boundary of a substation which delivers electric power to a railway;b) beside the track for the purpose of controlling or regulating the railway power supply, includingpower factor correction;c) along the track for the purpose of supplying electrical power to the railway other than by means ofthe conductors used for contact current collection, and associated return conductors. Included arehigh voltage feeder systems within the boundary of the railway which supply substations at whichthe voltage is reduced to the railway system voltage;d) beside the track for controlling or regulating electric power supplies to ancillary railway uses. Thiscategory includes power supplies to marshalling yards, maintenance depots and stations;e) various other non-traction power supplies from railway sources which are shared with railwaytraction.The immunity levels given in this standard apply for:- vital equipment such as protection devices;- equipment having connections to the traction power conductors;- apparatus inside the 3 m zone;- ports of apparatus inside the 10 m zone with connection inside the 3 m zone;- ports of apparatus inside the 10 m zone with cable length > 30 m.Apparatus and systems which are in an environment which can be described as residential,commercial or light industry, even when placed within the physical boundary of the railway substation,shall comply with EN 61000-6-1:2007 for immunity and EN 61000-6-3:2007 for emission requirements.Excluded from the immunity requirements of this standard is power supply apparatus which isintrinsically immune to the tests defined in Tables 1 to 6.NOTE An example is an 18 MVA 230 kV to 25 kV power supply transformer.These specific provisions are to be used in conjunction with the general provisions in EN 50121-1.This part of the standard covers requirements for both apparatus and fixed installations. The sectionsfor fixed installations are not relevant for CE marking.

Committee
CTN 203/SC 9X
DevelopmentNote
Supersedes UNE ENV 50121-5 (10/2003) NEW CHILD AMD 1 2019 IS NOW ADDED.
DocumentType
Standard
Pages
26
ProductNote
NEW CHILD AMD 1 2019 IS NOW ADDED.
THIS STANDARD ALSO REFERS TO EN 61000-4-5:2006
PublisherName
Asociación Española de Normalización
Status
Current

Standards Relationship
NEN EN 50121-5 : 2017 Identical
DIN EN 50121-5 : 2017 Identical
NF EN 50121-5 : 2017 Identical
EN 50121-5:2017 Identical
NBN EN 50121-5 : 2015 Identical
I.S. EN 50121-5:2017 Identical
BS EN 50121-5:2017 Identical

IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
EN 61000-3-11:2000 Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
EN 61000-3-3:2013 Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current
EN 50121-1:2017 Railway applications - Electromagnetic compatibility - Part 1: General
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
EN 61000-6-4:2007/A1:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 50121-2:2017 Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world
IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
EN 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and
EN 61000-4-4:2012 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
IEC 61000-4-18:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

€86.40
Excluding VAT