• Shopping Cart
    There are no items in your cart

UNE-EN 60601-2-4:2004

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Medical electrical equipment -- Part 2-4: Particular requirements for the safety of cardiac defibrillators

Available format(s)

Hardcopy , PDF

Withdrawn date

13-02-2014

Superseded by

UNE-EN 60601-2-4:2011

Language(s)

Spanish, Castilian

Published date

09-07-2004

€100.00
Excluding VAT

INTRODUCTION
SECTION ONE - GENERAL
1 Scope and object
2 Terminology and definitions
4 General requirements for tests
5 Classification
6 Identification, marking and documents
SECTION TWO - ENVIRONMENTAL CONDITIONS
10 Environmental conditions
SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK
HAZARDS
14 Requirements related to classification
17 Separation
19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY
    CURRENTS
20 Dielectric strength
SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
SECTION FIVE - PROTECTION AGAINST HAZARDS FROM
UNWANTED OR EXCESSIVE RADIATION
36 Electromagnetic compatibility (EMC)
SECTION SIX - PROTECTION AGAINST HAZARDS OF IGNITION OF
FLAMMABLE ANAESTHETIC MIXTURES
SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES
AND OTHER SAFETY HAZARDS
42 Excessive temperatures
44 Overflow, spillage, leakage, humidity, ingress of
    liquids, cleaning, sterilization, disinfection and
    compatibility
46 Human errors
SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION
AGAINST HAZARDOUS OUTPUT
50 Accuracy of operating data
51 Protection against hazardous output
SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS;
ENVIRONMENTAL TESTS
52 Abnormal operation and fault conditions
SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
56 Components and general assembly
57 MAINS PARTS, components and layout
SECTION 101 - ADDITIONAL REQUIREMENTS RELATING TO SAFETY
101 Charging time
102 Internal electrical power source
103 Endurance
104 Synchronizer
105 Recovery of the MONITOR/ECG INPUT after defibrillation
106 Disturbance to the monitor from charging or internal
    discharging
Appendix L References - Publications mentioned in this
           Standard
Annex AA (informative) General guidance and rationale
Annex BB (informative) AUTOMATED EXTERNAL DEFIBRILLATORS:
         background and rationale
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Annex ZB (informative) Other international publications
         mentioned in this standard with the reference of
         the European publications

Covers requirements for the safety of CARDIAC DEFIBRILLATORS, hereinafter referred to as EQUIPMENT.

Committee
CTN 209/SC 62D
DevelopmentNote
Supersedes UNE 20613-2-4. (10/2005)
DocumentType
Standard
Pages
60
PublisherName
Asociacion Espanola de Normalizacion
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
EN 60601-2-4:2003 Identical
IEC 60601-2-4:2002 Identical
EN 60601-2-4:2011 Identical
NF EN 60601-2-4 : 2012 Identical
BS EN 60601-2-4:2011 Identical
SN EN 60601-2-4 : 2003 Identical
DIN EN 60601-2-4 : 2012 Identical
I.S. EN 60601-2-4:2011 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.