UNI EN 1300 : 2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SECURE STORAGE UNITS - CLASSIFICATION FOR HIGH SECURITY LOCKS ACCORDING TO THEIR RESISTANCE TO UNAUTHORIZED OPENING
13-06-2019
01-01-2014
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Requirements
6 Technical documentation
7 Test specimens
8 Test methods
9 Test report
10 Marking
Annex A (normative) - Parameters for installation
and operating instructions
Annex B (normative) - Determination of manipulation
resistance due to the design requirement
Annex C (normative) - Manufacturer's Declaration
(applies only to key operated locks)
Annex D (informative) - Lock dimensions
Annex E (informative) - A-deviations
Bibliography
Defines requirements for high security locks (HSL) for reliability, resistance to burglary and unauthorized opening with methods of testing.
Committee |
U50.00
|
DevelopmentNote |
Supersedes UNI ENV 1300 (06/2005)
|
DocumentType |
Standard
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NS EN 1300 : 2013 | Identical |
NF EN 1300 : 2014 | Identical |
ONORM EN 1300 : MAY 2014 | Identical |
EN 1300:2018 | Identical |
SN EN 1300 : 2014 | Identical |
UNE-EN 1300:2014 | Identical |
NEN EN 1300 : 2013 | Identical |
NBN EN 1300 : 2014 | Identical |
I.S. EN 1300:2013 | Identical |
BS EN 1300:2013 | Identical |
EN 1300:2013 | Identical |
DIN EN 1300:2014-05 | Identical |
UNI 11557 : 2014 | NON-REGULATED PROFESSIONS - PROFESSIONAL LOCKSMITHS AND SAFE AND VAULT TECHNICIANS - KNOWLEDGE, SKILL AND COMPETENCE REQUIREMENTS |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 1143-1:2012 | Secure storage units - Requirements, classification and methods of test for resistance to burglary - Part 1: Safes, ATM safes, strongroom doors and strongrooms |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
FIPS PUB 140-2 : 0 | SECURITY REQUIREMENTS FOR CRYPTOGRAPHIC MODULES |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
ISO/IEC 9798-4:1999 | Information technology Security techniques Entity authentication Part 4: Mechanisms using a cryptographic check function |
ISO/IEC 9798-2:2008 | Information technology Security techniques Entity authentication Part 2: Mechanisms using symmetric encipherment algorithms |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN ISO 6988:1994 | Metallic and other non-organic coatings - Sulfur dioxide test with general condensation of moisture (ISO 6988:1985) |
FIPS PUB 197 : 2001 | ADVANCED ENCRYPTION STANDARD (AES) |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60721-3-4:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
ISO/IEC 9798-1:2010 | Information technology Security techniques Entity authentication Part 1: General |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.